Reference-Assisted FBG Sensing for Simultaneous Carotid–Radial Pulse-Wave Measurement and PWV Estimation

Simultaneous pulse-wave sensing at the carotid and radial arteries is challenging because the two sites require different mechanical coupling conditions and manually held carotid probes are susceptible to contact pressure and motion disturbances. This study presents a reference-assisted fiber Bragg grating (FBG) system comprising a wristband-type radial unit and a stamp-type carotid unit containing mechanically decoupled measurement and reference FBGs. Reference FBG regression (RFR) was used to suppress components shared by the carotid channels. In a 41.8 s recording from one male participant in his twenties, the reference and carotid measurement channels were essentially uncorrelated within the pulse-wave band (r = −0.05). After signal mean removal, RFR reduced power below 1 Hz by 74.3% without attenuating the pulse-band power (+11.4%), increasing the relative-power signal quality index from 0.174 to 0.458. Pulse transit time (PTT) was estimated by foot-centered windowed correlation. Analysis of 54 cardiac cycles yielded a representative PTT of 0.055 s. With an effective path length of 0.48 m, the corresponding pulse-wave velocity (PWV) was 8.7 m/s, with a within-record bootstrap 95% interval of 7.7–9.9 m/s. Estimates from eight non-overlapping 5 s segments were 9.1 ± 1.8 m/s. RFR produced lower segment-to-segment PTT variability than the baseline processing methods (coefficient of variation, 20.3% versus 34.6–46.7%). These results demonstrate the technical feasibility of reference-assisted FBG sensing for simultaneous carotid–radial pulse-wave acquisition and preliminary PWV estimation. Further validation requires higher-rate acquisition, repeated measurements, a larger cohort, and comparison with a reference PWV device.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-10-30
DOI
https://doi.org/10.3390/s26216879
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reference-Assisted FBG Sensing for Simultaneous Carotid–Radial Pulse-Wave Measurement and PWV Estimation

Minju Jeong, Seongmun Jeong, Hyung-Hoi KIm, Hwidon Lee et al.
1 links
Sensors
Non-Invasive Vital Sign Monitoring
article

Reference-Assisted FBG Sensing for Simultaneous Carotid–Radial Pulse-Wave Measurement and PWV Estimation

Minju Jeong, Seongmun Jeong, Hyung-Hoi KIm, Hwidon Lee, Chulhong Kim, Chang Hyun Park, Jeesu Kim, Min Hur, Yoonji Lee
article en

Abstract

Simultaneous pulse-wave sensing at the carotid and radial arteries is challenging because the two sites require different mechanical coupling conditions and manually held carotid probes are susceptible to contact pressure and motion disturbances. This study presents a reference-assisted fiber Bragg grating (FBG) system comprising a wristband-type radial unit and a stamp-type carotid unit containing mechanically decoupled measurement and reference FBGs. Reference FBG regression (RFR) was used to suppress components shared by the carotid channels. In a 41.8 s recording from one male participant in his twenties, the reference and carotid measurement channels were essentially uncorrelated within the pulse-wave band (r = −0.05). After signal mean removal, RFR reduced power below 1 Hz by 74.3% without attenuating the pulse-band power (+11.4%), increasing the relative-power signal quality index from 0.174 to 0.458. Pulse transit time (PTT) was estimated by foot-centered windowed correlation. Analysis of 54 cardiac cycles yielded a representative PTT of 0.055 s. With an effective path length of 0.48 m, the corresponding pulse-wave velocity (PWV) was 8.7 m/s, with a within-record bootstrap 95% interval of 7.7–9.9 m/s. Estimates from eight non-overlapping 5 s segments were 9.1 ± 1.8 m/s. RFR produced lower segment-to-segment PTT variability than the baseline processing methods (coefficient of variation, 20.3% versus 34.6–46.7%). These results demonstrate the technical feasibility of reference-assisted FBG sensing for simultaneous carotid–radial pulse-wave acquisition and preliminary PWV estimation. Further validation requires higher-rate acquisition, repeated measurements, a larger cohort, and comparison with a reference PWV device.

SensorsVol. 26(21)
Pusan National University (KR)
Korea Health Industry Development Institute, National Research Foundation of Korea
Good health and well-being
Openalex Percentile: Top 25%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon