Modified FBP and BPF algorithms for stationary computed tomography with linearly distributed sources

BackgroundStationary computed tomography with linearly distributed sources (SLCT) improves temporal resolution by avoiding gantry rotation. For the dual-SLCT (DSLCT) configuration, it faces challenges associated with redundancy and truncation issues in projection data. Existing FBP-based methods require complicated weighting strategies, whereas BPF-based methods for truncated data require geometry-specific formulations, which may limit their direct applicability to DSLCT.ObjectiveThis study presents two approaches to overcome the above challenges: a weighted Katsevich-type FBP (WK-FBP) algorithm and a locally refined backprojection filtration (LR-BPF) method.MethodsThe WK-FBP incorporates a Parker-like weighting strategy to handle data redundancy, applying weighting only to conjugate ray pairs during backprojection, thus simplifying the implementation process. The LR-BPF refines the classical BPF by locally adjusting the projection derivative, thereby accommodating linear scanning trajectories while effectively avoiding truncation artifacts. The two methods were evaluated under truncated and non-truncated conditions, with and without noise.ResultsBoth algorithms are applicable to DSLCT scanning. For non-truncated data, the WK-FBP achieves accurate image reconstruction. However, under truncation, WK-FBP reconstructions exhibit noticeable artifacts, whereas the LR-BPF consistently provides accurate results.ConclusionsWK-FBP is effective for DSLCT without truncation, whereas LR-BPF provides robust reconstruction performance under truncation.

Authors

Institutions

Publication Details

Journal
Journal of X-Ray Science and Technology
Published
2026-10-30
DOI
https://doi.org/10.1177/08953996261500842
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified FBP and BPF algorithms for stationary computed tomography with linearly distributed sources

Zhe Shi, Shi Daxin, Zhi Jun Yang, Juying HUANG et al.
Journal of X-Ray Science and Technology
Medical Imaging Techniques and Applications
article

Modified FBP and BPF algorithms for stationary computed tomography with linearly distributed sources

Zhe Shi, Shi Daxin, Zhi Jun Yang, Juying HUANG, Dan Wang, Yu Zou, Yi Yang
article en

Abstract

BackgroundStationary computed tomography with linearly distributed sources (SLCT) improves temporal resolution by avoiding gantry rotation. For the dual-SLCT (DSLCT) configuration, it faces challenges associated with redundancy and truncation issues in projection data. Existing FBP-based methods require complicated weighting strategies, whereas BPF-based methods for truncated data require geometry-specific formulations, which may limit their direct applicability to DSLCT.ObjectiveThis study presents two approaches to overcome the above challenges: a weighted Katsevich-type FBP (WK-FBP) algorithm and a locally refined backprojection filtration (LR-BPF) method.MethodsThe WK-FBP incorporates a Parker-like weighting strategy to handle data redundancy, applying weighting only to conjugate ray pairs during backprojection, thus simplifying the implementation process. The LR-BPF refines the classical BPF by locally adjusting the projection derivative, thereby accommodating linear scanning trajectories while effectively avoiding truncation artifacts. The two methods were evaluated under truncated and non-truncated conditions, with and without noise.ResultsBoth algorithms are applicable to DSLCT scanning. For non-truncated data, the WK-FBP achieves accurate image reconstruction. However, under truncation, WK-FBP reconstructions exhibit noticeable artifacts, whereas the LR-BPF consistently provides accurate results.ConclusionsWK-FBP is effective for DSLCT without truncation, whereas LR-BPF provides robust reconstruction performance under truncation.

Journal of X-Ray Science and Technology
Capital Medical University (CN)
National Natural Science Foundation of China, Beijing Municipal Health Commission
Openalex Percentile: Top 13%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon