Observation of Excess Benzene in Post-Fire Crude Oil and Risk Communication Implications

Abstract This investigation examines whether benzene in heat-affected crude oil declines as a volatility-only model would predict after tank-fire extinguishment with fluorine-free foam (F3). Among BTEX compounds, benzene has the highest vapor pressure and the lowest molecular weight and boiling point; it should therefore be depleted from the surface layer at least as fast as toluene, ethylbenzene, and the xylenes (TEX), and faster if evaporative loss dominates. Liquid samples were collected from the top 12 in. (30 cm) of a 2.4 m diameter × 2.19 m high test tank before burning and after repeated F3-extinguished burns. Aliquots were aerated in a closed vapor chamber and the headspace was analyzed as whole air. That assay characterizes an enriched source profile; the reported concentrations are not outdoor or breathing-zone exposures. Absolute benzene in the chamber headspace declined (81 ppmv in the single fresh-oil sample versus a post-burn mean of 31 ppmv), but TEX declined far more (for example, toluene from 680 ppmv to a post-burn mean of 26.5 ppmv). Benzene’s share of ΣBTEX vapor therefore rose from about 5% before burning to about 43% after burning (about 60% in overnight mixed-oil samples). A volatility-only account does not explain that pattern. A source term is required: conversion of precursors in the hot zone (thermal or steam-related cracking) and/or resupply of benzene from the cooler bulk liquid. Distinguishing those mechanisms is outside the scope of this observational study. The practical implication is that post-fire crude oil in deep tanks should not be assumed to have been stripped of benzene the way thin-film in situ burns are, and risk communication for responders should treat the residual liquid as a continuing benzene source.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-10-30
DOI
https://doi.org/10.21203/rs.3.rs-10879591/v1
Primary Topic
Oil Spill Detection and Mitigation
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Observation of Excess Benzene in Post-Fire Crude Oil and Risk Communication Implications

Prem Kumar Bikkina, Haejun Park, Scott B. Skelton, Michael Kubicki et al.
2 links
Research Square
Oil Spill Detection and Mitigation
preprint

Observation of Excess Benzene in Post-Fire Crude Oil and Risk Communication Implications

Prem Kumar Bikkina, Haejun Park, Scott B. Skelton, Michael Kubicki, Robert Agnew, Derek Kliethermes
preprint en

Abstract

Abstract This investigation examines whether benzene in heat-affected crude oil declines as a volatility-only model would predict after tank-fire extinguishment with fluorine-free foam (F3). Among BTEX compounds, benzene has the highest vapor pressure and the lowest molecular weight and boiling point; it should therefore be depleted from the surface layer at least as fast as toluene, ethylbenzene, and the xylenes (TEX), and faster if evaporative loss dominates. Liquid samples were collected from the top 12 in. (30 cm) of a 2.4 m diameter × 2.19 m high test tank before burning and after repeated F3-extinguished burns. Aliquots were aerated in a closed vapor chamber and the headspace was analyzed as whole air. That assay characterizes an enriched source profile; the reported concentrations are not outdoor or breathing-zone exposures. Absolute benzene in the chamber headspace declined (81 ppmv in the single fresh-oil sample versus a post-burn mean of 31 ppmv), but TEX declined far more (for example, toluene from 680 ppmv to a post-burn mean of 26.5 ppmv). Benzene’s share of ΣBTEX vapor therefore rose from about 5% before burning to about 43% after burning (about 60% in overnight mixed-oil samples). A volatility-only account does not explain that pattern. A source term is required: conversion of precursors in the hot zone (thermal or steam-related cracking) and/or resupply of benzene from the cooler bulk liquid. Distinguishing those mechanisms is outside the scope of this observational study. The practical implication is that post-fire crude oil in deep tanks should not be assumed to have been stripped of benzene the way thin-film in situ burns are, and risk communication for responders should treat the residual liquid as a continuing benzene source.

Research Square
Oklahoma State University (US)
Oil Spill Detection and Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon