Impact of Balloon‐Expandable Valve Asymmetry on Heart Failure Post Transcatheter Aortic Valve Replacement

Background Fluoroscopic assessment enables immediate evaluation of transcatheter heart valve expansion during transcatheter aortic valve replacement (TAVR). Whether fluoroscopic asymmetric expansion of balloon‐expandable valves is associated with post‐TAVR heart failure (HF) remains uncertain. Methods Among 607 consecutive patients undergoing balloon‐expandable valve‐TAVR in a prospective registry, 589 were analyzed. Valve asymmetry was quantified using a fluoroscopic asymmetry index (%), defined as [(longest/shortest balloon‐expandable valve height)−1]×100. The primary end point was 2‐year HF hospitalization. Results During follow‐up, 99 patients (17%) experienced HF hospitalization. As a continuous variable, asymmetry index (%) was not independently associated with 2‐year HF (adjusted hazard ratio [HR] per 1% increase, 1.02 [95% CI, 0.98–1.06]). Restricted cubic spline analysis demonstrated no significant linear or nonlinear association (overall P =0.71; P for nonlinearity=0.89), although the risk curve suggested increased HF risk beyond moderate valve asymmetry. Exploratory threshold analysis identified an asymmetry index cutoff of 7.48%. Patients above this threshold had a higher incidence of HF hospitalization than those below it (23.6% versus 15.8%; log‐rank P =0.043), despite comparable rates of impaired valve performance at discharge. Valve asymmetry >7.48% remained independently associated with late HF occurring beyond 30 days after TAVR (adjusted HR, 1.69 [95% CI, 1.10–2.60]). Conclusions Fluoroscopic assessment of balloon‐expandable valve expansion identified patients with marked valve asymmetry at increased risk of late HF after TAVR, despite preserved early valve performance. These findings support the potential value of intraprocedural valve geometry assessment for long‐term risk stratification and warrant further investigation.

Authors

Institutions

Publication Details

Journal
Journal of the American Heart Association
Published
2026-10-30
DOI
https://doi.org/10.1161/jaha.126.049304
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
4.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Balloon‐Expandable Valve Asymmetry on Heart Failure Post Transcatheter Aortic Valve Replacement

Kiyoshi Hibi, Kensuke Matsushita, Adrien Carmona, Benjamin Marchandot et al.
1 citations
Journal of the American Heart Association
Cardiac Valve Diseases and Treatments
4.96
article

Impact of Balloon‐Expandable Valve Asymmetry on Heart Failure Post Transcatheter Aortic Valve Replacement

Kiyoshi Hibi, Kensuke Matsushita, Adrien Carmona, Benjamin Marchandot, Olivier Morel, Patrick Ohlmann, Marion Kibler, Amandine Granier, Mickaël Ohana, Shinnosuke Kikuchi, Brooks M. Koenig, Antonin Trimaille, Manh Cuong Vu, Dorian Recht, Zoe Heyberger, Florian Loizon, Paul Knellwolf, Franck Zheng, Dinh Phi Truong, Julien Tse Sik Sun
article en
1 citations

Abstract

Background Fluoroscopic assessment enables immediate evaluation of transcatheter heart valve expansion during transcatheter aortic valve replacement (TAVR). Whether fluoroscopic asymmetric expansion of balloon‐expandable valves is associated with post‐TAVR heart failure (HF) remains uncertain. Methods Among 607 consecutive patients undergoing balloon‐expandable valve‐TAVR in a prospective registry, 589 were analyzed. Valve asymmetry was quantified using a fluoroscopic asymmetry index (%), defined as [(longest/shortest balloon‐expandable valve height)−1]×100. The primary end point was 2‐year HF hospitalization. Results During follow‐up, 99 patients (17%) experienced HF hospitalization. As a continuous variable, asymmetry index (%) was not independently associated with 2‐year HF (adjusted hazard ratio [HR] per 1% increase, 1.02 [95% CI, 0.98–1.06]). Restricted cubic spline analysis demonstrated no significant linear or nonlinear association (overall P =0.71; P for nonlinearity=0.89), although the risk curve suggested increased HF risk beyond moderate valve asymmetry. Exploratory threshold analysis identified an asymmetry index cutoff of 7.48%. Patients above this threshold had a higher incidence of HF hospitalization than those below it (23.6% versus 15.8%; log‐rank P =0.043), despite comparable rates of impaired valve performance at discharge. Valve asymmetry >7.48% remained independently associated with late HF occurring beyond 30 days after TAVR (adjusted HR, 1.69 [95% CI, 1.10–2.60]). Conclusions Fluoroscopic assessment of balloon‐expandable valve expansion identified patients with marked valve asymmetry at increased risk of late HF after TAVR, despite preserved early valve performance. These findings support the potential value of intraprocedural valve geometry assessment for long‐term risk stratification and warrant further investigation.

Journal of the American Heart Association
Hanoi Medical University (VN), Yokohama City University Medical Center (JP), Hôpitaux Universitaires de Strasbourg (FR), Bạch Mai Hospital (VN), Hôpital Civil, Strasbourg (FR), Université de Strasbourg (FR), Yokohama City University (JP)
Good health and well-being
Openalex Percentile: Top 4%
Cardiac Valve Diseases and Treatments
4.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon