Design and statistical validation of low-cost electrogoniometers for elbow orthosis applications

This study presents the design, implementation, and statistical validation of four low-cost electromechanical electrogoniometers for elbow joint angle measurement in orthotic applications. The proposed systems are based on distinct sensing principles: an infrared (IR) optical sensor, a calibrated IR optical sensor, a rotary potentiometer, and a slide potentiometer, all integrated into a custom mechanical structure that enables indirect measurement while reducing mechanical stress on sensing components. Experimental validation was performed using a controlled elbow motion simulator and human subjects, with measurements compared against a reference digital goniometer. Performance metrics included mean absolute error (MAE), repeatability, linearity (R²), and statistical agreement. A one-way ANOVA revealed significant differences among sensing modalities (p < 0.05), and Tukey's post hoc analysis confirmed that the IR-based system exhibited significantly higher errors than calibrated IRbased and both potentiometer-based systems. Bland-Altman analysis demonstrated strong agreement for calibrated IR-based and potentiometer-based designs, with minimal bias and narrow limits of agreement. The calibrated IR achieved the highest accuracy (MAE ≈ 2.78°), while the slide potentiometer provided a favorable balance between performance (MAE ≈ 4.72°) and mechanical integration. These results indicate that potentiometer-based electrogoniometers are suitable for wearable rehabilitation systems requiring reliable and realtime joint monitoring. The proposed designs offer cost-effective alternatives for biomechanical instrumentation and support the development of accessible assistive technologies.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-10-30
DOI
https://doi.org/10.1088/2057-1976/aebbc1
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and statistical validation of low-cost electrogoniometers for elbow orthosis applications

Lorenzo García, Adriana del Carmen Téllez-Anguiano, José Felipe Escobedo-Magallán, Manuel Áviles-Jr
2 links
Biomedical Physics & Engineering Express
Prosthetics and Rehabilitation Robotics
article

Design and statistical validation of low-cost electrogoniometers for elbow orthosis applications

Lorenzo García, Adriana del Carmen Téllez-Anguiano, José Felipe Escobedo-Magallán, Manuel Áviles-Jr
article en

Abstract

This study presents the design, implementation, and statistical validation of four low-cost electromechanical electrogoniometers for elbow joint angle measurement in orthotic applications. The proposed systems are based on distinct sensing principles: an infrared (IR) optical sensor, a calibrated IR optical sensor, a rotary potentiometer, and a slide potentiometer, all integrated into a custom mechanical structure that enables indirect measurement while reducing mechanical stress on sensing components. Experimental validation was performed using a controlled elbow motion simulator and human subjects, with measurements compared against a reference digital goniometer. Performance metrics included mean absolute error (MAE), repeatability, linearity (R²), and statistical agreement. A one-way ANOVA revealed significant differences among sensing modalities (p < 0.05), and Tukey's post hoc analysis confirmed that the IR-based system exhibited significantly higher errors than calibrated IRbased and both potentiometer-based systems. Bland-Altman analysis demonstrated strong agreement for calibrated IR-based and potentiometer-based designs, with minimal bias and narrow limits of agreement. The calibrated IR achieved the highest accuracy (MAE ≈ 2.78°), while the slide potentiometer provided a favorable balance between performance (MAE ≈ 4.72°) and mechanical integration. These results indicate that potentiometer-based electrogoniometers are suitable for wearable rehabilitation systems requiring reliable and realtime joint monitoring. The proposed designs offer cost-effective alternatives for biomechanical instrumentation and support the development of accessible assistive technologies.

Biomedical Physics & Engineering Express
Auckland University of Technology (NZ), Instituto Tecnológico de Morelia (MX)
Good health and well-being
Openalex Percentile: Top 25%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Design and statistical validation of low-cost electrogoniometers for elbow orthosis applications — Lorenzo García, Adriana del Carmen Téllez-Anguiano, et al. · Biomedical Physics & Engineering Express (2026) | TGRS Research Map | TGRS