A NEW ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ANALYSIS OF TUCATINIB IN BULK AND MARKETED FORMULATION BY RP HPLC METHOD

An analytical, specific, accurate, precise, robust, efficient and simple RP-HPLC method has been developed and validated for the determination of Tucatinib in bulk and was applied on marketed Tucatinib products. The mobile phase used for the chromatographic runs consisted of Phosphate Buffer (0.02M) and Acetonitrile in the proportion of 48:52% with maintained at pH-2.80 by diluted OPA solution. The separation was achieved on a Symmetry ODS (C18) RP Column, 250 mm x 4.6 mm, 5µm column using isocratic mode. Drug peak were well separated and were detected by a UV detector at 248 nm. The method was linear at the concentration range 30–70 μg/ml for Tucatinib. The method has been validated according to ICH guidelines with respect to system suitability, specificity, precision, accuracy and robustness. Tucatinib limit of detection (LOD) and limit of quantification (LOQ) were 0.09μg/ml and 0.27μg/ml respectively. Keywords: Tucatinib, RP-HPLC, Accuracy, Precision, Robustness, ICH Guidelines.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-30
DOI
https://doi.org/10.5281/zenodo.23800677
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A NEW ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ANALYSIS OF TUCATINIB IN BULK AND MARKETED FORMULATION BY RP HPLC METHOD

Adla Sangeetha*, M. Sruthi, Kondapally Chakravarthi, Kosgi Sowmya
3 links
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

A NEW ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ANALYSIS OF TUCATINIB IN BULK AND MARKETED FORMULATION BY RP HPLC METHOD

Adla Sangeetha*, M. Sruthi, Kondapally Chakravarthi, Kosgi Sowmya
article en

Abstract

An analytical, specific, accurate, precise, robust, efficient and simple RP-HPLC method has been developed and validated for the determination of Tucatinib in bulk and was applied on marketed Tucatinib products. The mobile phase used for the chromatographic runs consisted of Phosphate Buffer (0.02M) and Acetonitrile in the proportion of 48:52% with maintained at pH-2.80 by diluted OPA solution. The separation was achieved on a Symmetry ODS (C18) RP Column, 250 mm x 4.6 mm, 5µm column using isocratic mode. Drug peak were well separated and were detected by a UV detector at 248 nm. The method was linear at the concentration range 30–70 μg/ml for Tucatinib. The method has been validated according to ICH guidelines with respect to system suitability, specificity, precision, accuracy and robustness. Tucatinib limit of detection (LOD) and limit of quantification (LOQ) were 0.09μg/ml and 0.27μg/ml respectively. Keywords: Tucatinib, RP-HPLC, Accuracy, Precision, Robustness, ICH Guidelines.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 19%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.