Ultrasound assessment of lumbar disc height in physical therapy exercises

Purpose. Lumbar stabilisation exercises assume that body positions load or unload the intervertebral disc (IVD) predictably, yet several of these positions cannot be reproduced inside a magnetic resonance scanner, so in vivo evidence is scarce. This study established whether ventral lumbar IVD height can be measured by transabdominal ultrasound in six physical therapy positions. Materials & Methods. Adescriptive, within-participant repeated-measures study was conducted. Ten healthy adults (9 men, 1 woman; 18–50 years; BMI 18.4–25.7 kg/m², from retrospectively self-reported height) assumed six positions in one session: supine, standing, bird-dog, modified Biering-Sørensen, standing with an axial barbell load (50 kg men, 30 kg women) and overhead-bar traction. Ventral IVD height at L3–L4 and L4–L5 was measured by a single experienced sonographer. Estimates are reported as means with SD and 95% CI. Results. All 120 disc–position combinations were measured (100%; 95% CI 97–100%; participant level 10/10, 95% CI 69–100%), including under load and suspension. Mean height ranged from 6.08 to 6.83 mm. Stable between-participant differences accounted for 56% and 49% of total variability; the mean within-participant SD was 0.56–0.58 mm. At L3–L4 the largest mean reduction from supine occurred under axial load (−0.74 mm) but varied widely between participants, whereas the modified Biering-Sørensen position gave a smaller but far more consistent reduction (−0.45 mm). No such pattern appeared at L4–L5. Conclusions. Transabdominal ultrasound measured ventral lumbar IVD height in all six positions, including those inaccessible to conventional imaging, with within-participant variability of about 0.6 mm. Position-related differences were small relative to this variability, and no position, including overhead-bar traction, increased ventral disc height.

Authors

Institutions

Publication Details

Journal
Physical rehabilitation and recreational health technologies
Published
2026-10-30
DOI
https://doi.org/10.15391/prrht.2026-11(5).04
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound assessment of lumbar disc height in physical therapy exercises

Юлія Валеріївна Антонова-Рафі, Денис Нагорний, Neonilla Leontiuk, Yevhenii Uhlov
1 links
Physical rehabilitation and recreational health technologies
Spine and Intervertebral Disc Pathology
article

Ultrasound assessment of lumbar disc height in physical therapy exercises

Юлія Валеріївна Антонова-Рафі, Денис Нагорний, Neonilla Leontiuk, Yevhenii Uhlov
article en

Abstract

Purpose. Lumbar stabilisation exercises assume that body positions load or unload the intervertebral disc (IVD) predictably, yet several of these positions cannot be reproduced inside a magnetic resonance scanner, so in vivo evidence is scarce. This study established whether ventral lumbar IVD height can be measured by transabdominal ultrasound in six physical therapy positions. Materials & Methods. Adescriptive, within-participant repeated-measures study was conducted. Ten healthy adults (9 men, 1 woman; 18–50 years; BMI 18.4–25.7 kg/m², from retrospectively self-reported height) assumed six positions in one session: supine, standing, bird-dog, modified Biering-Sørensen, standing with an axial barbell load (50 kg men, 30 kg women) and overhead-bar traction. Ventral IVD height at L3–L4 and L4–L5 was measured by a single experienced sonographer. Estimates are reported as means with SD and 95% CI. Results. All 120 disc–position combinations were measured (100%; 95% CI 97–100%; participant level 10/10, 95% CI 69–100%), including under load and suspension. Mean height ranged from 6.08 to 6.83 mm. Stable between-participant differences accounted for 56% and 49% of total variability; the mean within-participant SD was 0.56–0.58 mm. At L3–L4 the largest mean reduction from supine occurred under axial load (−0.74 mm) but varied widely between participants, whereas the modified Biering-Sørensen position gave a smaller but far more consistent reduction (−0.45 mm). No such pattern appeared at L4–L5. Conclusions. Transabdominal ultrasound measured ventral lumbar IVD height in all six positions, including those inaccessible to conventional imaging, with within-participant variability of about 0.6 mm. Position-related differences were small relative to this variability, and no position, including overhead-bar traction, increased ventral disc height.

Physical rehabilitation and recreational health technologiesVol. 11(5)
E.O. Paton Electric Welding Institute (UA), National Academy of Sciences of Ukraine (UA), National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” (UA)
Good health and well-being
Openalex Percentile: Top 12%
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.