Assessing the Climate Robustness of Residential Shading Devices across Multiple Climate Zones under Future Climate Scenarios

Climate change is the most critical environmental phenomenon humanity is facing in recent and coming decades, and its impacts are intensifying heat waves and increasing cooling energy demand. In this context, shading devices emerge as essential low-cost passive strategy to mitigate overheating and maintaining indoor thermal comfort. This study assesses the climate robustness, energy, and thermal performance of residential shading devices across multiple Algerian climate zones, Mediterranean (Csa), semi-arid (BSk, BSh), and hot desert climate (BWh), under both historical and future climate scenarios (RCP 4.5 and RCP 8.5 for mid- and end-century horizons). Using EnergyPlus dynamic simulations, validated through ASHRAE Guideline 14 and optimized via the Non-dominated Sorting Genetic Algorithm (NSGA-II), fourteen shading configurations were tested in combination with single and double low-emissivity (Low-E) glazing and both conventional and insulated walls. The results reveal that combined 3D shading systems, such as egg-crate and overhangs combined with side fins, achieve the highest cuts in solar gains, up to 60–80% when coupled with double Low-E glazing. Conversely, simple single-element devices, such as basic overhangs or side fins, show lower performance and reduced stability under future extreme arid conditions. A Composite Robustness Index (CRI) constructed through an equally weighted additive aggregation of variance, interquartile range, coherence, and percentile metrics, demonstrates that combined and deeper shading devices maintain consistently higher robustness under future climate conditions. The findings affirm that adaptive shading design is crucial for residential buildings under projected climate conditions. Integrating shading with appropriate insulated envelopes can substantially enhance resilience, reduce cooling energy demand, and support a smooth transition toward low-carbon, and climate-responsive architecture in Mediterranean and North African cities.

Authors

Institutions

Publication Details

Journal
Isı Bilimi ve Tekniği Dergisi
Published
2026-10-30
DOI
https://doi.org/10.47480/isibted.1822766
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Climate Robustness of Residential Shading Devices across Multiple Climate Zones under Future Climate Scenarios

Soufiane Boukarta
4 links
Isı Bilimi ve Tekniği Dergisi
Building Energy and Comfort Optimization
article

Assessing the Climate Robustness of Residential Shading Devices across Multiple Climate Zones under Future Climate Scenarios

Soufiane Boukarta
article en

Abstract

Climate change is the most critical environmental phenomenon humanity is facing in recent and coming decades, and its impacts are intensifying heat waves and increasing cooling energy demand. In this context, shading devices emerge as essential low-cost passive strategy to mitigate overheating and maintaining indoor thermal comfort. This study assesses the climate robustness, energy, and thermal performance of residential shading devices across multiple Algerian climate zones, Mediterranean (Csa), semi-arid (BSk, BSh), and hot desert climate (BWh), under both historical and future climate scenarios (RCP 4.5 and RCP 8.5 for mid- and end-century horizons). Using EnergyPlus dynamic simulations, validated through ASHRAE Guideline 14 and optimized via the Non-dominated Sorting Genetic Algorithm (NSGA-II), fourteen shading configurations were tested in combination with single and double low-emissivity (Low-E) glazing and both conventional and insulated walls. The results reveal that combined 3D shading systems, such as egg-crate and overhangs combined with side fins, achieve the highest cuts in solar gains, up to 60–80% when coupled with double Low-E glazing. Conversely, simple single-element devices, such as basic overhangs or side fins, show lower performance and reduced stability under future extreme arid conditions. A Composite Robustness Index (CRI) constructed through an equally weighted additive aggregation of variance, interquartile range, coherence, and percentile metrics, demonstrates that combined and deeper shading devices maintain consistently higher robustness under future climate conditions. The findings affirm that adaptive shading design is crucial for residential buildings under projected climate conditions. Integrating shading with appropriate insulated envelopes can substantially enhance resilience, reduce cooling energy demand, and support a smooth transition toward low-carbon, and climate-responsive architecture in Mediterranean and North African cities.

Isı Bilimi ve Tekniği DergisiVol. 46(2)
University of Blida (DZ)
Climate action, Sustainable cities and communities, Affordable and clean energy, Industry, innovation and infrastructure
Openalex Percentile: Top 16%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon