Physicochemical stability of furosemide in elastomeric devices at 1 and 10 mg/mL

Objectives Furosemide is a loop diuretic used for the rapid management of fluid overload and oedema associated with cardiac, renal or hepatic disorders. Intravenous furosemide can be administered either as a continuous infusion or as an intermittent bolus. This study aimed to evaluate the physicochemical stability of furosemide solutions at 1 and 10 mg/mL diluted in 0.9% NaCl in silicone elastomeric devices at 32°C to support continuous infusion in outpatient and home-based care settings. Stability was tested after preparation and after 6, 24 and 48 hours of storage. Methods Three portable elastomeric devices were prepared for each condition. Chemical stability was assessed by pH measurement and high-performance liquid chromatography (HPLC). The method was validated according to the International Conference on Harmonisation Q2(R2). At each time point of analysis the pH was measured and three samples from each device were analysed via HPLC. The solution is chemically stable if it retains more than 90% of its initial concentration, with the appearance of any degradation products monitored and if the pH variation is less than one unit. Physical stability was evaluated by visual and subvisual inspection using a particle counter. Results For both concentrations, visual and subvisual inspection was compliant at each analysis time. Physical stability was therefore demonstrated for both concentrations after 48 hours. Furosemide solutions at both concentrations maintained more than 90% of their initial concentration for 48 hours at 32°C. The pH decreased during the stability study. Conclusions The physicochemical stability of the furosemide solutions in elastomeric devices at 32°C was demonstrated for 24 hours at 1 mg/mL and for 48 hours at 10 mg/mL. The observed decrease in pH was the limiting factor in establishing the shelf life of the 1 mg/mL solutions. These findings support the use of continuous furosemide infusion in home care settings.

Authors

Institutions

Publication Details

Journal
European Journal of Hospital Pharmacy
Published
2026-10-30
DOI
https://doi.org/10.1136/ejhpharm-2026-005219
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physicochemical stability of furosemide in elastomeric devices at 1 and 10 mg/mL

Franck Blaise, Nathalie Sobalak, Élise D’Huart, Béatrice Demoré et al.
1 links
European Journal of Hospital Pharmacy
Analytical Methods in Pharmaceuticals
article

Physicochemical stability of furosemide in elastomeric devices at 1 and 10 mg/mL

Franck Blaise, Nathalie Sobalak, Élise D’Huart, Béatrice Demoré, Caroline Marquet
article en

Abstract

Objectives Furosemide is a loop diuretic used for the rapid management of fluid overload and oedema associated with cardiac, renal or hepatic disorders. Intravenous furosemide can be administered either as a continuous infusion or as an intermittent bolus. This study aimed to evaluate the physicochemical stability of furosemide solutions at 1 and 10 mg/mL diluted in 0.9% NaCl in silicone elastomeric devices at 32°C to support continuous infusion in outpatient and home-based care settings. Stability was tested after preparation and after 6, 24 and 48 hours of storage. Methods Three portable elastomeric devices were prepared for each condition. Chemical stability was assessed by pH measurement and high-performance liquid chromatography (HPLC). The method was validated according to the International Conference on Harmonisation Q2(R2). At each time point of analysis the pH was measured and three samples from each device were analysed via HPLC. The solution is chemically stable if it retains more than 90% of its initial concentration, with the appearance of any degradation products monitored and if the pH variation is less than one unit. Physical stability was evaluated by visual and subvisual inspection using a particle counter. Results For both concentrations, visual and subvisual inspection was compliant at each analysis time. Physical stability was therefore demonstrated for both concentrations after 48 hours. Furosemide solutions at both concentrations maintained more than 90% of their initial concentration for 48 hours at 32°C. The pH decreased during the stability study. Conclusions The physicochemical stability of the furosemide solutions in elastomeric devices at 32°C was demonstrated for 24 hours at 1 mg/mL and for 48 hours at 10 mg/mL. The observed decrease in pH was the limiting factor in establishing the shelf life of the 1 mg/mL solutions. These findings support the use of continuous furosemide infusion in home care settings.

European Journal of Hospital Pharmacy
Inserm (FR), Centre Hospitalier Régional et Universitaire de Nancy (FR), Interdisciplinarité en Santé Publique Interventions et Instruments de mesure complexes – Région Est (FR), Université de Lorraine (FR)
Good health and well-being
Openalex Percentile: Top 19%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon