VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF LOSARTAN AND AMLODIPINE IN BULK AND TABLET DOSAGE FORM

A simple, precise, and validated Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) method was developed for the simultaneous estimation of Losartan and Amlodipine in bulk and tablet dosage forms. The chromatographic analysis was carried out using a Develosil C18 column (4.6 mm × 250 mm, 5 µm) maintained at ambient temperature. The mobile phase comprised Acetonitrile and Acetate buffer (pH 4.3) in the ratio of 35:65% v/v, delivered at a flow rate of 1 mL/min. Detection was performed at a wavelength of 238 nm, with an injection volume of 20 µL and a run time of 6 minutes. The method produced well-resolved peaks for both Losartan and Amlodipine with consistent retention times and no interference from excipients. It was validated in accordance with ICH Q2(R1) guidelines, demonstrating excellent linearity, precision, accuracy, specificity, and robustness. The results confirm that this RP-HPLC method is suitable for the routine quality control of Losartan and Amlodipine in combined pharmaceutical dosage forms. Keywords: RP-HPLC, Losartan, Amlodipine, Develosil C18 column, linearity, accuracy.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-30
DOI
https://doi.org/10.5281/zenodo.23807047
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF LOSARTAN AND AMLODIPINE IN BULK AND TABLET DOSAGE FORM

K. Usha Akula Srilekha
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF LOSARTAN AND AMLODIPINE IN BULK AND TABLET DOSAGE FORM

K. Usha Akula Srilekha
article en

Abstract

A simple, precise, and validated Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) method was developed for the simultaneous estimation of Losartan and Amlodipine in bulk and tablet dosage forms. The chromatographic analysis was carried out using a Develosil C18 column (4.6 mm × 250 mm, 5 µm) maintained at ambient temperature. The mobile phase comprised Acetonitrile and Acetate buffer (pH 4.3) in the ratio of 35:65% v/v, delivered at a flow rate of 1 mL/min. Detection was performed at a wavelength of 238 nm, with an injection volume of 20 µL and a run time of 6 minutes. The method produced well-resolved peaks for both Losartan and Amlodipine with consistent retention times and no interference from excipients. It was validated in accordance with ICH Q2(R1) guidelines, demonstrating excellent linearity, precision, accuracy, specificity, and robustness. The results confirm that this RP-HPLC method is suitable for the routine quality control of Losartan and Amlodipine in combined pharmaceutical dosage forms. Keywords: RP-HPLC, Losartan, Amlodipine, Develosil C18 column, linearity, accuracy.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 19%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon