Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism

OBJECTIVE: Accurate interpretation of planar ventilation-perfusion (V/Q) scintigraphy, used for diagnosing pulmonary embolism (PE) based on PIOPED/EANM guidelines, requires objective assessment of mismatched V/Q defects. Manual delineation of V/Q defects is time-consuming, subject to interobserver variability, and rarely performed in practice, limiting standardized reporting and quantification of disease burden. To address these challenges, we evaluated four modern AI models for automated segmentation of vascular perfusion defects in planar V/Q scans and compared their performance to human annotators. APPROACH: We retrospectively identified 2,118 patients who underwent planar V/Q scans at The Ottawa Hospital (June 2019-February 2023). Six standard projections (ANT, POST, LAO, RAO, LPO, RPO) were included. Four 2D neural networks (U-Net, nnU-Net, Swin UNETR, and a Bottleneck Transformer U-Net [BTU-Net]) were trained on 1,313 patients (7,878 projections) and validated on 329 (1,974 projections) using physician-annotated defects. A hold-out test set of 46 high probability patients was used to evaluate segmentation quality, and defect detection accuracy using free-response receiver operating characteristic (FROC) analysis. MAIN RESULTS: BTU-Net was the only model performing on par with human readers, showing robust sensitivity across the entire range of segmentation probabilities. At 1.5 false positives per projection rate (FPPR), BTU-Net outperformed other models with sensitivity of 0.529 ± 0.026, On a separate hold-out set of low likelihood of disease patients (n=430), the lowest FPPR was 0.08 ± 0.01 for BTU-Net (P<0.0001). SIGNIFICANCE: BTU-Net enables rapid, consistent, and accurate interpretation of planar V/Q scans. Such tools may enhance diagnostic efficiency, standardize reporting, and support non-expert readers in evaluating PE.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-10-30
DOI
https://doi.org/10.1088/1361-6560/aebc06
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism

Ramin Akbarian, Richard F. Liu, Eric Jr Moulton, Amir Jabbarpour et al.
2 links
Physics in Medicine and Biology
Medical Image Segmentation Techniques
article

Artificial intelligence-enabled detection of vascular perfusion defects on ventilation/perfusion (V/Q) scintigraphy for pulmonary embolism

Ramin Akbarian, Richard F. Liu, Eric Jr Moulton, Amir Jabbarpour, Yousif A. Lucinian, Ran Klein, Sanaz I. Kaviani, Siraj Ghassel, Nuha Hejji, Wanzhen Zeng, Eugene Leung, Anne Couture, Aubert Roy, Sukainah AlSulaiman, Yasser Foufa, Zeinab Shirazi
article en

Abstract

OBJECTIVE: Accurate interpretation of planar ventilation-perfusion (V/Q) scintigraphy, used for diagnosing pulmonary embolism (PE) based on PIOPED/EANM guidelines, requires objective assessment of mismatched V/Q defects. Manual delineation of V/Q defects is time-consuming, subject to interobserver variability, and rarely performed in practice, limiting standardized reporting and quantification of disease burden. To address these challenges, we evaluated four modern AI models for automated segmentation of vascular perfusion defects in planar V/Q scans and compared their performance to human annotators. APPROACH: We retrospectively identified 2,118 patients who underwent planar V/Q scans at The Ottawa Hospital (June 2019-February 2023). Six standard projections (ANT, POST, LAO, RAO, LPO, RPO) were included. Four 2D neural networks (U-Net, nnU-Net, Swin UNETR, and a Bottleneck Transformer U-Net [BTU-Net]) were trained on 1,313 patients (7,878 projections) and validated on 329 (1,974 projections) using physician-annotated defects. A hold-out test set of 46 high probability patients was used to evaluate segmentation quality, and defect detection accuracy using free-response receiver operating characteristic (FROC) analysis. MAIN RESULTS: BTU-Net was the only model performing on par with human readers, showing robust sensitivity across the entire range of segmentation probabilities. At 1.5 false positives per projection rate (FPPR), BTU-Net outperformed other models with sensitivity of 0.529 ± 0.026, On a separate hold-out set of low likelihood of disease patients (n=430), the lowest FPPR was 0.08 ± 0.01 for BTU-Net (P<0.0001). SIGNIFICANCE: BTU-Net enables rapid, consistent, and accurate interpretation of planar V/Q scans. Such tools may enhance diagnostic efficiency, standardize reporting, and support non-expert readers in evaluating PE.

Physics in Medicine and Biology
University of Ottawa (CA), Montreal Heart Institute (CA), Ottawa Hospital (CA), Jewish General Hospital (CA), Hôpital Maisonneuve-Rosemont (CA), McGill University (CA), Carleton University (CA)
Government of Canada, Mitacs
Good health and well-being
Openalex Percentile: Top 17%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon