Optimizing Pipe Diameters in Drip Irrigation Systems through Spatial Grouping of Subplots into Irrigation Shifts

Efficient hydraulic design of drip irrigation systems requires pipe sizing to account for the spatial distribution of irrigation demand and the sequence of system operation. When pump capacity limits the area irrigated simultaneously, different combinations of active subplots can produce different hydraulic conditions despite maintaining the same total discharge. This study develops a method that integrates spatial subplot grouping into operating shifts with hydraulic network analysis to support pipe diameter selection. The method combines equal-area field subdivision, max–min pairing based on centroid distances, pump discharge constraints, and hydraulic calculations for each operating shift. An irregular field of approximately 19.02 ha was divided into 12 subplots and organized into six paired shifts. Each planned shift covered approximately 3.17 ha at a discharge of 111.24 m³ h⁻¹, with a scheduled irrigation sequence lasting 18.81 h. Centroid distances between paired subplots ranged from 287.20 to 349.24 m. Preliminary hydraulic calculations covering 11 connected subplots showed that the five complete paired shifts required pumping heads of 22.71–25.00 m at approximately equal inlet discharge. The maximum mainline velocity was 0.98 m s⁻¹, below the adopted limit of 2.2 m s⁻¹. These results demonstrate that equal discharge does not eliminate differences in hydraulic loading and that pipe sizing must consider the governing operating shift. The proposed approach can support preliminary design and operational assessment of drip irrigation networks on irregular fields where pump capacity requires rotational irrigation, providing a basis for comparing subplot groupings and evaluating commercial pipe diameters.

Authors

Institutions

Publication Details

Journal
Journal of Hydraulic and Environmental Engineering
Published
2026-10-30
DOI
https://doi.org/10.35938/jhee-2026-1-00006
Primary Topic
Irrigation Practices and Water Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Pipe Diameters in Drip Irrigation Systems through Spatial Grouping of Subplots into Irrigation Shifts

Sirojiddin Jalilov, Arken Tursun, Khumora Jalilova, Arifjanov Aybek Muxamedjanovich et al.
1 links
Journal of Hydraulic and Environmental Engineering
Irrigation Practices and Water Management
article

Optimizing Pipe Diameters in Drip Irrigation Systems through Spatial Grouping of Subplots into Irrigation Shifts

Sirojiddin Jalilov, Arken Tursun, Khumora Jalilova, Arifjanov Aybek Muxamedjanovich, Lukmon Samiev, Mardon Reimbayev
article en

Abstract

Efficient hydraulic design of drip irrigation systems requires pipe sizing to account for the spatial distribution of irrigation demand and the sequence of system operation. When pump capacity limits the area irrigated simultaneously, different combinations of active subplots can produce different hydraulic conditions despite maintaining the same total discharge. This study develops a method that integrates spatial subplot grouping into operating shifts with hydraulic network analysis to support pipe diameter selection. The method combines equal-area field subdivision, max–min pairing based on centroid distances, pump discharge constraints, and hydraulic calculations for each operating shift. An irregular field of approximately 19.02 ha was divided into 12 subplots and organized into six paired shifts. Each planned shift covered approximately 3.17 ha at a discharge of 111.24 m³ h⁻¹, with a scheduled irrigation sequence lasting 18.81 h. Centroid distances between paired subplots ranged from 287.20 to 349.24 m. Preliminary hydraulic calculations covering 11 connected subplots showed that the five complete paired shifts required pumping heads of 22.71–25.00 m at approximately equal inlet discharge. The maximum mainline velocity was 0.98 m s⁻¹, below the adopted limit of 2.2 m s⁻¹. These results demonstrate that equal discharge does not eliminate differences in hydraulic loading and that pipe sizing must consider the governing operating shift. The proposed approach can support preliminary design and operational assessment of drip irrigation networks on irregular fields where pump capacity requires rotational irrigation, providing a basis for comparing subplot groupings and evaluating commercial pipe diameters.

Journal of Hydraulic and Environmental EngineeringVol. 4(2)
Chinese Academy of Sciences (CN), Xinjiang Institute of Ecology and Geography (CN), Tashkent Institute of Irrigation and Agricultural Mechanization Engineers (UZ)
Zero hunger
Openalex Percentile: Top 15%
Irrigation Practices and Water Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon