A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring

Abstract The Internet of Medical Things requires physiological monitoring systems that balance temporal signal dynamics, relational structure, and computational efficiency. This study presents a lightweight hybrid LSTM–GNN framework for binary ECG screening, integrating explicit graph message passing, temporal modelling, and an ECG-derived proxy-context node. The framework was evaluated on 47 MIT-BIH records using strict record-wise splitting, preprocessing designed to avoid information leakage, and a fixed 0.50 decision threshold across five random seeds. In addition, an external cross-database evaluation was conducted on the INCART database without fine-tuning or threshold tuning, using a harmonized binary label mapping. On MIT-BIH, the Full Hybrid condition achieved the highest mean Accuracy (0.8991 ± 0.0363) and F1-score (0.8121 ± 0.0573), together with the lowest false-alarm rate (0.1129 ± 0.0523) among the evaluated conditions. On the external INCART database, the Full Hybrid condition achieved a mean Accuracy of 0.8801 ± 0.0151 and ROC-AUC of 0.9065 ± 0.0227 under the fixed external-test protocol. The ablation analysis indicated measurable contributions from the combined representations, while the context-permutation analysis showed that the proxy context should not be interpreted as an independent modality. In addition, software-level runtime profiling using ONNX Runtime demonstrated software-level portability characteristics and runtime efficiency on a standard CPU environment, with 8066 parameters, an approximately 36.1-kB model file, and a median CPU latency of 0.076 ms. The reported variability summarizes performance variation across five random seeds reflecting training stability, and should not be interpreted as patient-level inferential confidence intervals. These findings support reproducible, lightweight cross-database evaluation under the specified harmonization protocol, while limiting the claims to software-level computational feasibility rather than physical edge deployment, independent multimodal sensing, autonomous adaptive behavior, or established clinical utility.

Authors

Publication Details

Journal
Discover Artificial Intelligence
Published
2026-10-30
DOI
https://doi.org/10.1007/s44163-026-02679-x
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring

Mohamed Mostafa AbdulAli
Discover Artificial Intelligence
ECG Monitoring and Analysis
article

A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring

Mohamed Mostafa AbdulAli
article en

Abstract

Abstract The Internet of Medical Things requires physiological monitoring systems that balance temporal signal dynamics, relational structure, and computational efficiency. This study presents a lightweight hybrid LSTM–GNN framework for binary ECG screening, integrating explicit graph message passing, temporal modelling, and an ECG-derived proxy-context node. The framework was evaluated on 47 MIT-BIH records using strict record-wise splitting, preprocessing designed to avoid information leakage, and a fixed 0.50 decision threshold across five random seeds. In addition, an external cross-database evaluation was conducted on the INCART database without fine-tuning or threshold tuning, using a harmonized binary label mapping. On MIT-BIH, the Full Hybrid condition achieved the highest mean Accuracy (0.8991 ± 0.0363) and F1-score (0.8121 ± 0.0573), together with the lowest false-alarm rate (0.1129 ± 0.0523) among the evaluated conditions. On the external INCART database, the Full Hybrid condition achieved a mean Accuracy of 0.8801 ± 0.0151 and ROC-AUC of 0.9065 ± 0.0227 under the fixed external-test protocol. The ablation analysis indicated measurable contributions from the combined representations, while the context-permutation analysis showed that the proxy context should not be interpreted as an independent modality. In addition, software-level runtime profiling using ONNX Runtime demonstrated software-level portability characteristics and runtime efficiency on a standard CPU environment, with 8066 parameters, an approximately 36.1-kB model file, and a median CPU latency of 0.076 ms. The reported variability summarizes performance variation across five random seeds reflecting training stability, and should not be interpreted as patient-level inferential confidence intervals. These findings support reproducible, lightweight cross-database evaluation under the specified harmonization protocol, while limiting the claims to software-level computational feasibility rather than physical edge deployment, independent multimodal sensing, autonomous adaptive behavior, or established clinical utility.

Discover Artificial IntelligenceVol. 6(1)
Good health and well-being
Openalex Percentile: Top 11%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring — Mohamed Mostafa AbdulAli · Discover Artificial Intelligence (2026) | TGRS Research Map | TGRS