Assessing Observable Resolution in Open-Access sEMG Datasets for High-Resolution Hand-Gesture Research: A Quantization-Aware Methodological Study

Open-access surface electromyography (sEMG) datasets are widely used for gesture-recognition research; however, limited documentation of acquisition and post-processing may prevent verification of whether the numerical structure imposed during acquisition is preserved in the distributed data. This study evaluates one selected signal vector from each of eleven public forearm sEMG datasets using a quantization-aware framework, complemented by an assessment across participants and channels to examine within-dataset consistency. The framework distinguishes declared resolution (DR) from observable effective resolution (OER), a signal-dependent descriptor of the numerical granularity observable in the distributed data rather than a measure of hardware ENOB. The analysis uses the minimum nonzero first-order difference (Δmin), zero-difference proportion (P0), relative signal cardinality, and a quantization-grid alignment metric (Egrid) to characterize numerical discreteness and grid preservation. Recordings analyzed from five datasets exhibited ordered difference levels consistent with a preserved observable quantization grid, whereas those from six showed disrupted structures. The complementary assessment revealed both consistent numerical patterns and within-dataset variability across the examined recordings. Egrid quantified approximate grid alignment at the adopted tolerance, while P0 and cardinality served as complementary descriptors. Validation using an independently documented 24-bit dataset yielded Egrid = 1, despite low P0 and high cardinality, demonstrating that these indirect descriptors depend on signal and acquisition characteristics. The results show that nominal analog-to-digital converter (ADC) resolution and stored numerical precision alone cannot establish acquisition-level quantization integrity. Numerical auditing can therefore provide additional traceability when public datasets are used to investigate signal resolution and quantization effects.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-10-30
DOI
https://doi.org/10.3390/s26216890
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Observable Resolution in Open-Access sEMG Datasets for High-Resolution Hand-Gesture Research: A Quantization-Aware Methodological Study

José Alejandro Amézquita García, Fabian Natanael Murrieta-Rico, Miguel E. Bravo-Zanoguera, Alexandra Gomez-Caraveo et al.
1 links
Sensors
Muscle activation and electromyography studies
article

Assessing Observable Resolution in Open-Access sEMG Datasets for High-Resolution Hand-Gesture Research: A Quantization-Aware Methodological Study

José Alejandro Amézquita García, Fabian Natanael Murrieta-Rico, Miguel E. Bravo-Zanoguera, Alexandra Gomez-Caraveo, G. Galaviz
article en

Abstract

Open-access surface electromyography (sEMG) datasets are widely used for gesture-recognition research; however, limited documentation of acquisition and post-processing may prevent verification of whether the numerical structure imposed during acquisition is preserved in the distributed data. This study evaluates one selected signal vector from each of eleven public forearm sEMG datasets using a quantization-aware framework, complemented by an assessment across participants and channels to examine within-dataset consistency. The framework distinguishes declared resolution (DR) from observable effective resolution (OER), a signal-dependent descriptor of the numerical granularity observable in the distributed data rather than a measure of hardware ENOB. The analysis uses the minimum nonzero first-order difference (Δmin), zero-difference proportion (P0), relative signal cardinality, and a quantization-grid alignment metric (Egrid) to characterize numerical discreteness and grid preservation. Recordings analyzed from five datasets exhibited ordered difference levels consistent with a preserved observable quantization grid, whereas those from six showed disrupted structures. The complementary assessment revealed both consistent numerical patterns and within-dataset variability across the examined recordings. Egrid quantified approximate grid alignment at the adopted tolerance, while P0 and cardinality served as complementary descriptors. Validation using an independently documented 24-bit dataset yielded Egrid = 1, despite low P0 and high cardinality, demonstrating that these indirect descriptors depend on signal and acquisition characteristics. The results show that nominal analog-to-digital converter (ADC) resolution and stored numerical precision alone cannot establish acquisition-level quantization integrity. Numerical auditing can therefore provide additional traceability when public datasets are used to investigate signal resolution and quantization effects.

SensorsVol. 26(21)
Universidad Politécnica de Baja California (MX), Universidad Autónoma de Baja California (MX)
Openalex Percentile: Top 25%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon