Experimental and Numerical Investigation of Orthotropic CFR-PEEK and Ti-6Al-4V Osteosynthesis Plates Using a Multiscale Finite Element Modeling Approach

The application of carbon fiber-reinforced polyetheretherketone (CFR-PEEK) composites in osteosynthesis implants represents a promising approach to mitigating the stress-shielding effect associated with the high stiffness of conventional metallic implants. This study aimed to experimentally and numerically evaluate the effects of short carbon fiber content and the orthotropic mechanical properties of CFR-PEEK on the structural strength of osteosynthesis plates and load distribution within the bone–plate system. The investigation employed a multiscale approach integrating micromechanical modeling using the Mori–Tanaka homogenization method in Digimat-MF, experimental mechanical testing of FDM-fabricated CFR-PEEK specimens containing 10 wt.% carbon fibers, and finite element analysis of osteosynthesis plates made of CFR-PEEK with 10 and 30 wt.% carbon fibers and Ti-6Al-4V using MSC Patran/Marc. CFR-PEEK 30% specimens were neither fabricated nor experimentally tested. Their mechanical properties were predicted using Digimat-MF by applying correction factors derived from experimental data obtained for CFR-PEEK 10%. The results demonstrated that increasing the carbon fiber content from 10 to 30 wt.% enhanced the longitudinal elastic modulus. Experimental testing of CFR-PEEK containing 10 wt.% carbon fibers revealed an elastic modulus ranging from 1.76 to 3.10 GPa and a tensile strength of 47–54 MPa. Following process-related adjustments to the material properties, finite element simulations of the bone–plate system were performed under an axial load of 50 N. The calculated load shielding indices were 94.3% for Ti-6Al-4V, 28.6% for CFR-PEEK 10%, and 54.3% for CFR-PEEK 30%, indicating the potential of composite implants to improve mechanical load transfer to the surrounding bone tissue. A preliminary strength assessment based on the three-dimensional Tsai–Hill failure criterion yielded failure indices of 15.577 and 1.112 for CFR-PEEK 10% and CFR-PEEK 30%, respectively, under the assumed material strength parameters. Critical stress concentrations were predominantly localized around the fixation holes. These findings highlight the trade-off between reducing stress shielding and ensuring the structural integrity of composite osteosynthesis plates. The results further emphasize the need for localized optimization of fixation regions to improve mechanical reliability without increasing the overall implant thickness.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-10-30
DOI
https://doi.org/10.3390/polym18212693
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Numerical Investigation of Orthotropic CFR-PEEK and Ti-6Al-4V Osteosynthesis Plates Using a Multiscale Finite Element Modeling Approach

Исаметова Мадина Есдаулетовна, Шолпан Курманова, Arailym Tursynbayeva, Е. С. Ильясов et al.
1 links
Polymers
Bone fractures and treatments
article

Experimental and Numerical Investigation of Orthotropic CFR-PEEK and Ti-6Al-4V Osteosynthesis Plates Using a Multiscale Finite Element Modeling Approach

Исаметова Мадина Есдаулетовна, Шолпан Курманова, Arailym Tursynbayeva, Е. С. Ильясов, Nurgul Seiitkazy, Tkachenko Denis
article en

Abstract

The application of carbon fiber-reinforced polyetheretherketone (CFR-PEEK) composites in osteosynthesis implants represents a promising approach to mitigating the stress-shielding effect associated with the high stiffness of conventional metallic implants. This study aimed to experimentally and numerically evaluate the effects of short carbon fiber content and the orthotropic mechanical properties of CFR-PEEK on the structural strength of osteosynthesis plates and load distribution within the bone–plate system. The investigation employed a multiscale approach integrating micromechanical modeling using the Mori–Tanaka homogenization method in Digimat-MF, experimental mechanical testing of FDM-fabricated CFR-PEEK specimens containing 10 wt.% carbon fibers, and finite element analysis of osteosynthesis plates made of CFR-PEEK with 10 and 30 wt.% carbon fibers and Ti-6Al-4V using MSC Patran/Marc. CFR-PEEK 30% specimens were neither fabricated nor experimentally tested. Their mechanical properties were predicted using Digimat-MF by applying correction factors derived from experimental data obtained for CFR-PEEK 10%. The results demonstrated that increasing the carbon fiber content from 10 to 30 wt.% enhanced the longitudinal elastic modulus. Experimental testing of CFR-PEEK containing 10 wt.% carbon fibers revealed an elastic modulus ranging from 1.76 to 3.10 GPa and a tensile strength of 47–54 MPa. Following process-related adjustments to the material properties, finite element simulations of the bone–plate system were performed under an axial load of 50 N. The calculated load shielding indices were 94.3% for Ti-6Al-4V, 28.6% for CFR-PEEK 10%, and 54.3% for CFR-PEEK 30%, indicating the potential of composite implants to improve mechanical load transfer to the surrounding bone tissue. A preliminary strength assessment based on the three-dimensional Tsai–Hill failure criterion yielded failure indices of 15.577 and 1.112 for CFR-PEEK 10% and CFR-PEEK 30%, respectively, under the assumed material strength parameters. Critical stress concentrations were predominantly localized around the fixation holes. These findings highlight the trade-off between reducing stress shielding and ensuring the structural integrity of composite osteosynthesis plates. The results further emphasize the need for localized optimization of fixation regions to improve mechanical reliability without increasing the overall implant thickness.

PolymersVol. 18(21)
Satbayev University (KZ)
Good health and well-being
Openalex Percentile: Top 12%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon