Multi-objective optimization of light guide column injection molding process using RSM and NSGA‑II with numerical verification

Injection molding technology involves fully melting plastic material through screw agitation at a specific temperature, injecting it into the mold cavity under high pressure, and obtaining the molded part after cooling and solidification. Injection molding offers high production efficiency while meeting the molding demands of complex plastic components. However, enhancing the dimensional accuracy of injection-molded parts has become a critical aspect of this process. The injection-molded components of the XG-99Q2 light guide column were selected as the subject of this study. Initially, three runner system designs were created: "Wang" shape, 'Gong' shape, and "Yi" shape configurations. Each design underwent process analysis for its respective injection molding process. Subsequently, six fundamental injection parameters were identified, and an L32 orthogonal experimental design was employed to systematically investigate their effects on two critical objectives: plastic volume shrinkage and warpage deformation. The experimental design incorporated signal-to-noise ratio processing, with weights for total warpage and volume shrinkage derived using the entropy weight method. This approach facilitated qualitative analysis of gray correlation coefficients and correlations among identified factors, revealing significant relationships between injection time, holding pressure, and melt temperature. Prediction models for warpage and shrinkage were developed using the Box-Behnken experimental design from response surface methodology, providing a foundation for comprehensive quantitative analysis. Additionally, the NSGA-II algorithm was applied to multi-objective optimization, yielding a set of Pareto optimal solutions. Finally, the reliability of the method was verified through simulation based validation.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-10-30
DOI
https://doi.org/10.1371/journal.pone.0361371
Primary Topic
Injection Molding Process and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-objective optimization of light guide column injection molding process using RSM and NSGA‑II with numerical verification

XU Huajun
2 links
PLoS ONE
Injection Molding Process and Properties
article

Multi-objective optimization of light guide column injection molding process using RSM and NSGA‑II with numerical verification

XU Huajun
article en

Abstract

Injection molding technology involves fully melting plastic material through screw agitation at a specific temperature, injecting it into the mold cavity under high pressure, and obtaining the molded part after cooling and solidification. Injection molding offers high production efficiency while meeting the molding demands of complex plastic components. However, enhancing the dimensional accuracy of injection-molded parts has become a critical aspect of this process. The injection-molded components of the XG-99Q2 light guide column were selected as the subject of this study. Initially, three runner system designs were created: "Wang" shape, 'Gong' shape, and "Yi" shape configurations. Each design underwent process analysis for its respective injection molding process. Subsequently, six fundamental injection parameters were identified, and an L32 orthogonal experimental design was employed to systematically investigate their effects on two critical objectives: plastic volume shrinkage and warpage deformation. The experimental design incorporated signal-to-noise ratio processing, with weights for total warpage and volume shrinkage derived using the entropy weight method. This approach facilitated qualitative analysis of gray correlation coefficients and correlations among identified factors, revealing significant relationships between injection time, holding pressure, and melt temperature. Prediction models for warpage and shrinkage were developed using the Box-Behnken experimental design from response surface methodology, providing a foundation for comprehensive quantitative analysis. Additionally, the NSGA-II algorithm was applied to multi-objective optimization, yielding a set of Pareto optimal solutions. Finally, the reliability of the method was verified through simulation based validation.

PLoS ONEVol. 21(10)
Anhui Water Conservancy Technical College (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 23%
Injection Molding Process and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Multi-objective optimization of light guide column injection molding process using RSM and NSGA‑II with numerical verification — XU Huajun · PLoS ONE (2026) | TGRS Research Map | TGRS