Finite element analysis of C-shaped auxetic reentrant structure validated experimentally: Insights into buckling and mechanical behavior

This study examines the mechanical behavior of a C-shaped reentrant auxetic cylindrical structure using finite element analysis (FEA) for five unit-cell configurations, with the length and height varied together (l = h) from 8 to 11 mm. Experimental validation was conducted for the 9.5 mm configuration. The results show a gradual decrease in peak force from 870 N at 8 mm to 418 N at 11 mm. For the 9.5 mm configuration, the experimental peak force was 602.8 N, and the force-displacement response agreed reasonably well with the FE predictions before the peak, although differences became more pronounced during post-peak deformation. A similar trend was observed in stiffness, which decreased from 1712.5 N/mm for the 8 mm model to 294.9 N/mm for the 11 mm model. The experimental stiffness at 9.5 mm was 560.0 N/mm. The energy absorbed over the first 4 mm of displacement was 1.87 J in the FE model and 1.13 J in the experiment, indicating that the numerical model overestimated the measured energy absorption. The Poisson's ratio remained negative across the investigated configurations, ranging from −1.21 to −2.12, confirming the auxetic response of the structure. These findings indicate that the reentrant geometry offers potential for vibration-control applications in optical equipment. Nevertheless, its effectiveness within the 10–1000 Hz frequency range remains to be established through dynamic testing. The differences between the numerical predictions and experimental measurements also suggest that material behavior, contact conditions, friction, and mesh convergence warrant further investigation to improve the reliability of the FE model.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications
Published
2026-10-30
DOI
https://doi.org/10.1177/14644207261502651
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element analysis of C-shaped auxetic reentrant structure validated experimentally: Insights into buckling and mechanical behavior

邹鲁德, Mostafa Habibi, Penghui Luo, Xianheng Ai
2 links
Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications
Cellular and Composite Structures
article

Finite element analysis of C-shaped auxetic reentrant structure validated experimentally: Insights into buckling and mechanical behavior

邹鲁德, Mostafa Habibi, Penghui Luo, Xianheng Ai
article en

Abstract

This study examines the mechanical behavior of a C-shaped reentrant auxetic cylindrical structure using finite element analysis (FEA) for five unit-cell configurations, with the length and height varied together (l = h) from 8 to 11 mm. Experimental validation was conducted for the 9.5 mm configuration. The results show a gradual decrease in peak force from 870 N at 8 mm to 418 N at 11 mm. For the 9.5 mm configuration, the experimental peak force was 602.8 N, and the force-displacement response agreed reasonably well with the FE predictions before the peak, although differences became more pronounced during post-peak deformation. A similar trend was observed in stiffness, which decreased from 1712.5 N/mm for the 8 mm model to 294.9 N/mm for the 11 mm model. The experimental stiffness at 9.5 mm was 560.0 N/mm. The energy absorbed over the first 4 mm of displacement was 1.87 J in the FE model and 1.13 J in the experiment, indicating that the numerical model overestimated the measured energy absorption. The Poisson's ratio remained negative across the investigated configurations, ranging from −1.21 to −2.12, confirming the auxetic response of the structure. These findings indicate that the reentrant geometry offers potential for vibration-control applications in optical equipment. Nevertheless, its effectiveness within the 10–1000 Hz frequency range remains to be established through dynamic testing. The differences between the numerical predictions and experimental measurements also suggest that material behavior, contact conditions, friction, and mesh convergence warrant further investigation to improve the reliability of the FE model.

Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications
Haliç University (TR), China Nonferrous Metal Mining (China) (CN), Yunnan University of Finance And Economics (CN), Saveetha University (IN)
National Natural Science Foundation of China
Openalex Percentile: Top 23%
Cellular and Composite Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon