Experiment-informed simulation of hydrogen fuel cell auxiliary power units for maritime decarbonisation

The continuous rating of a multi-cell proton-exchange-membrane (PEM) fuel cell stack is normally inferred from mean polarisation behaviour, yet sustained operation is limited by the weakest cell. Here, cell voltages measured on a 20-cell, 250 cm 2 short stack over 27 operating points (0-1.8 A cm −2 ) are used to infer cell-to-cell variation in ohmic resistance and limiting current density, from which a virtual 300-cell, 60 kW-class stack is sampled. Voltage dispersion grows from below 1 mV near open circuit to ∼36 mV at the 62.9 kW peak, and the minimum cell voltage falls below 0.45 V above ∼1.5 A cm −2 , so cell spread, not mean performance, sets the continuous limit. The limit falls at the same set-point in 91% of 10,000 sampled stacks, but a 20-cell stack from the same population overstates it by about 6%. Published degradation behaviour reduces it to 1.10-1.30 A cm −2 at end of life. For a modular marine auxiliary power unit, levelised cost is £0.42-0.82 kWh −1 at £4-£10 kg −1 H 2 and operational carbon intensity is ∼85% below diesel. The method gives stack manufacturers and marine integrators a practical route to rating a full-size stack on its weakest cell before it is built.

Authors

Institutions

Publication Details

Journal
Journal of Power Sources
Published
2026-10-30
DOI
https://doi.org/10.1016/j.jpowsour.2026.241835
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experiment-informed simulation of hydrogen fuel cell auxiliary power units for maritime decarbonisation

Oliver James Curnick, Sumit Roy
2 links
Journal of Power Sources
Fuel Cells and Related Materials
article

Experiment-informed simulation of hydrogen fuel cell auxiliary power units for maritime decarbonisation

Oliver James Curnick, Sumit Roy
article en

Abstract

The continuous rating of a multi-cell proton-exchange-membrane (PEM) fuel cell stack is normally inferred from mean polarisation behaviour, yet sustained operation is limited by the weakest cell. Here, cell voltages measured on a 20-cell, 250 cm 2 short stack over 27 operating points (0-1.8 A cm −2 ) are used to infer cell-to-cell variation in ohmic resistance and limiting current density, from which a virtual 300-cell, 60 kW-class stack is sampled. Voltage dispersion grows from below 1 mV near open circuit to ∼36 mV at the 62.9 kW peak, and the minimum cell voltage falls below 0.45 V above ∼1.5 A cm −2 , so cell spread, not mean performance, sets the continuous limit. The limit falls at the same set-point in 91% of 10,000 sampled stacks, but a 20-cell stack from the same population overstates it by about 6%. Published degradation behaviour reduces it to 1.10-1.30 A cm −2 at end of life. For a modular marine auxiliary power unit, levelised cost is £0.42-0.82 kWh −1 at £4-£10 kg −1 H 2 and operational carbon intensity is ∼85% below diesel. The method gives stack manufacturers and marine integrators a practical route to rating a full-size stack on its weakest cell before it is built.

Journal of Power SourcesVol. 699
Coventry University (GB)
HORIZON EUROPE Framework Programme
Affordable and clean energy, Climate action
Openalex Percentile: Top 24%
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Experiment-informed simulation of hydrogen fuel cell auxiliary power units for maritime decarbonisation — Oliver James Curnick, Sumit Roy · Journal of Power Sources (2026) | TGRS Research Map | TGRS