Voltage-Dependent Dielectrophoretic Response of Bacterial Cells: Implications for Reliable Cell Manipulation

Abstract Rapid bacterial detection is important for environmental monitoring, particularly for identifying microbial contamination in water resources. Dielectrophoresis (DEP) provides a label-free approach for bacterial detection by exploiting differences in cellular dielectric properties. Our previous studies established bacterial movement velocity, force, and crossover frequency as quantitative parameters toward the development of a DEP-based detection platform. However, optimization of the operating conditions is necessary to ensure reliable measurement. During voltage optimization, unexpected positive DEP (pDEP) was observed at low frequencies where negative DEP (nDEP) was expected, particularly at 20 Vpp. This study therefore investigated whether applied voltage affects bacterial viability and membrane integrity during DEP experiment. Escherichia coli and Staphylococcus aureus (pH 7), were exposed to 3–20 Vpp at 50 kHz, followed by pDEP quantification, colony-forming unit (CFU) analysis, Live/Dead fluorescence staining, and transmission electron microscopy (TEM). Despite increasing pDEP occurrence at higher voltages, CFU analysis showed no significant differences in culturability (p > 0.05). In contrast, fluorescence and TEM analyses revealed voltage-dependent changes in membrane integrity and structure. These findings indicate that DEP exposure can induce sublethal membrane perturbation sufficient to alter bacterial dielectric response without measurable loss of culturability. Appropriate voltage selection is therefore critical for preserving measurement reliability in DEP-based bacterial detection and its future application to environmental monitoring.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-10-30
DOI
https://doi.org/10.21203/rs.3.rs-11226601/v1
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Voltage-Dependent Dielectrophoretic Response of Bacterial Cells: Implications for Reliable Cell Manipulation

Arash Zulkarnain Ahmad Rozaini, Noraziah Mohamad Zin, Muhamad Ramdzan Buyong, Akmal Suhaimi et al.
Research Square
Microfluidic and Bio-sensing Technologies
preprint

Voltage-Dependent Dielectrophoretic Response of Bacterial Cells: Implications for Reliable Cell Manipulation

Arash Zulkarnain Ahmad Rozaini, Noraziah Mohamad Zin, Muhamad Ramdzan Buyong, Akmal Suhaimi, Muhammad Faez Aris
preprint en

Abstract

Abstract Rapid bacterial detection is important for environmental monitoring, particularly for identifying microbial contamination in water resources. Dielectrophoresis (DEP) provides a label-free approach for bacterial detection by exploiting differences in cellular dielectric properties. Our previous studies established bacterial movement velocity, force, and crossover frequency as quantitative parameters toward the development of a DEP-based detection platform. However, optimization of the operating conditions is necessary to ensure reliable measurement. During voltage optimization, unexpected positive DEP (pDEP) was observed at low frequencies where negative DEP (nDEP) was expected, particularly at 20 Vpp. This study therefore investigated whether applied voltage affects bacterial viability and membrane integrity during DEP experiment. Escherichia coli and Staphylococcus aureus (pH 7), were exposed to 3–20 Vpp at 50 kHz, followed by pDEP quantification, colony-forming unit (CFU) analysis, Live/Dead fluorescence staining, and transmission electron microscopy (TEM). Despite increasing pDEP occurrence at higher voltages, CFU analysis showed no significant differences in culturability (p > 0.05). In contrast, fluorescence and TEM analyses revealed voltage-dependent changes in membrane integrity and structure. These findings indicate that DEP exposure can induce sublethal membrane perturbation sufficient to alter bacterial dielectric response without measurable loss of culturability. Appropriate voltage selection is therefore critical for preserving measurement reliability in DEP-based bacterial detection and its future application to environmental monitoring.

Research Square
National University of Malaysia (MY)
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Voltage-Dependent Dielectrophoretic Response of Bacterial Cells: Implications for Reliable Cell Manipulation — Arash Zulkarnain Ahmad Rozaini, Noraziah Mohamad Zin, et al. · Research Square (2026) | TGRS Research Map | TGRS