Neutron spectrometry of (p,n) based neutron fields at the University of Helsinki using the NCT-WES single-moderator directional spectrometer

A tunable-energy neutron beam produced with up to 1 $μ$A / 10 MeV proton beam on a solid LiF target is available at the Department of Physics of the University of Helsinki for neutron metrology and research applications. This work presents the experimental characterisation of the neutron beams produced at the Helsinki Accelerator Laboratory, and the validation of the \texttt{MCNP6} and \texttt{GEANT4} radiation transport codes for simulating these neutron beams. The neutron spectra produced in the forward direction from 1960, 2040, and 2310 keV protons were measured using the NCT-WES single-moderator directional spectrometer. NCT-WES (Neutron Capture Therapy Wide Energy Spectrometer) is a recently developed single-moderator neutron spectrometer with a sharply directional response, and it is a very convenient instrument to characterise neutron facilities, as it determines the whole spectrum in a single exposure, and has a low sensitivity to room-scattering. The neutron fluence was also determined with the Berthold LB 6411 neutron monitor. The data acquired with NCT-WES were unfolded using the FRUIT unfolding code, starting from guess spectra obtained from \texttt{GEANT4} or \texttt{MCNP6} simulations. The unfolding analysis showed that both transport codes produced plausible spectra, \texttt{MCNP6} being more accurate for the 1960 and 2040 keV irradiations and \texttt{GEANT4} for 2310 keV. The measured values of energy-integrated neutron fluence agree satisfactorily with simulations as well as preliminary measurements with the LB 6411 neutron monitor.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-10-29
DOI
https://doi.org/10.48550/arxiv.2610.39763
Primary Topic
Nuclear Physics and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Neutron spectrometry of (p,n) based neutron fields at the University of Helsinki using the NCT-WES single-moderator directional spectrometer

S. Saariokari, M. Myllymäki, E. Brücken, T. Siiskonen et al.
arXiv (Cornell University)
Nuclear Physics and Applications
preprint

Neutron spectrometry of (p,n) based neutron fields at the University of Helsinki using the NCT-WES single-moderator directional spectrometer

S. Saariokari, M. Myllymäki, E. Brücken, T. Siiskonen, M. Väänänen, J. M. Gomez-Ros, T. Hildén, J. Huikari, J. Lapa, H. Badran, A. I. Castro Campoy, A. Pietropaolo, A. Perkkiö, R. Bedogni, L. Russo, F. L. Frigi, K. Helariutta
preprint en

Abstract

A tunable-energy neutron beam produced with up to 1 $μ$A / 10 MeV proton beam on a solid LiF target is available at the Department of Physics of the University of Helsinki for neutron metrology and research applications. This work presents the experimental characterisation of the neutron beams produced at the Helsinki Accelerator Laboratory, and the validation of the \texttt{MCNP6} and \texttt{GEANT4} radiation transport codes for simulating these neutron beams. The neutron spectra produced in the forward direction from 1960, 2040, and 2310 keV protons were measured using the NCT-WES single-moderator directional spectrometer. NCT-WES (Neutron Capture Therapy Wide Energy Spectrometer) is a recently developed single-moderator neutron spectrometer with a sharply directional response, and it is a very convenient instrument to characterise neutron facilities, as it determines the whole spectrum in a single exposure, and has a low sensitivity to room-scattering. The neutron fluence was also determined with the Berthold LB 6411 neutron monitor. The data acquired with NCT-WES were unfolded using the FRUIT unfolding code, starting from guess spectra obtained from \texttt{GEANT4} or \texttt{MCNP6} simulations. The unfolding analysis showed that both transport codes produced plausible spectra, \texttt{MCNP6} being more accurate for the 1960 and 2040 keV irradiations and \texttt{GEANT4} for 2310 keV. The measured values of energy-integrated neutron fluence agree satisfactorily with simulations as well as preliminary measurements with the LB 6411 neutron monitor.

arXiv (Cornell University)
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Neutron spectrometry of (p,n) based neutron fields at the University of Helsinki using the NCT-WES single-moderator directional spectrometer — S. Saariokari, M. Myllymäki, et al. · arXiv (Cornell University) (2026) | TGRS Research Map | TGRS