Microwave Sensor-Based Systems for Real-Time Detection of Microplastics in Water: A Review of Resonator Sensing, Microfluidic Integration, Machine Learning and Portable System Design

Microplastics (<5 mm) are now found in oceans, rivers, drinking water and human blood, yet routine monitoring is limited because reference methods such as Fourier-transform infrared (FTIR) and Raman spectroscopy are laboratory-bound, slow and costly. Microwave resonator sensing offers a low-cost, non-optical alternative: the large permittivity contrast between water (~80) and common polymers (~2–3.5) means suspended particles shift a planar resonator's resonance frequency, quality factor and transmission/reflection response. This narrative review covers sensing theory, resonator design, microfluidic sample handling, machine-learning interpretation (K-nearest neighbours, convolutional neural networks) and portable, wireless integration. Reviewed studies report resonance shifts of ~100 to >500 MHz, a theoretical resolution of ~100 ppm, a limit of detection of 48.72 ng/mL (microfluidic-CNN seawater system), response times below 250 ms, and prediction accuracies of 96–98 % within ±0.01 mg/mL. However, most studies use few polymers, filtered or artificial matrices, laboratory network analysers, non-standard concentration units and random data splits, and few address temperature or salinity compensation or long-term field operation; the seawater study's quoted detection limit and tolerance also need independent confirmation. We contribute a comparative analysis of representative studies, a conceptual architecture for field-deployable, IoT-connected monitoring, and a prioritised research agenda.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-30
DOI
https://doi.org/10.5281/zenodo.23804341
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microwave Sensor-Based Systems for Real-Time Detection of Microplastics in Water: A Review of Resonator Sensing, Microfluidic Integration, Machine Learning and Portable System Design

S. B. Bhosale, Prajyot Prakash Vishwasrao
6 links
Zenodo (CERN European Organization for Nuclear Research)
Microwave and Dielectric Measurement Techniques
article

Microwave Sensor-Based Systems for Real-Time Detection of Microplastics in Water: A Review of Resonator Sensing, Microfluidic Integration, Machine Learning and Portable System Design

S. B. Bhosale, Prajyot Prakash Vishwasrao
article en

Abstract

Microplastics (<5 mm) are now found in oceans, rivers, drinking water and human blood, yet routine monitoring is limited because reference methods such as Fourier-transform infrared (FTIR) and Raman spectroscopy are laboratory-bound, slow and costly. Microwave resonator sensing offers a low-cost, non-optical alternative: the large permittivity contrast between water (~80) and common polymers (~2–3.5) means suspended particles shift a planar resonator's resonance frequency, quality factor and transmission/reflection response. This narrative review covers sensing theory, resonator design, microfluidic sample handling, machine-learning interpretation (K-nearest neighbours, convolutional neural networks) and portable, wireless integration. Reviewed studies report resonance shifts of ~100 to >500 MHz, a theoretical resolution of ~100 ppm, a limit of detection of 48.72 ng/mL (microfluidic-CNN seawater system), response times below 250 ms, and prediction accuracies of 96–98 % within ±0.01 mg/mL. However, most studies use few polymers, filtered or artificial matrices, laboratory network analysers, non-standard concentration units and random data splits, and few address temperature or salinity compensation or long-term field operation; the seawater study's quoted detection limit and tolerance also need independent confirmation. We contribute a comparative analysis of representative studies, a conceptual architecture for field-deployable, IoT-connected monitoring, and a prioritised research agenda.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 24%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon