TiCoCr‐Based Multi‐Principal Element Alloys for Biomedical Applications

ABSTRACT Next‐generation biomedical implants require materials with excellent wear resistance, corrosion resistance, and biocompatibility. This study developed two novel multi‐principal element alloys (MPEAs) based on the TiCoCr composition (equiatomic and non‐equiatomic) with ultra‐high hardness, excellent wear resistance, corrosion stability, and biocompatibility. The as‐cast microstructures revealed a multiphase combination of Ti‐rich hexagonal closed packing (HCP), C 14 Laves, and face‐centered cubic (FCC) phases. Upon heat treatment, equiatomic (Ti 33 Co 33 Cr 33 ) MPEA developed two major body‐centered (BCC) phases and a minor HCP phase, whereas heat treatment of non‐equiatomic (Ti 50 Co 25 Cr 25 ) MPEA revealed one BCC and C 14 Laves phase. The hardness of both MPEAs was slightly reduced after heat treatment. Wear and corrosion tests conducted in Hanks' balanced salt solution (HBSS) at 37°C on heat‐treated MPEAs demonstrated improved tribological and corrosion behavior, with reduced wear and a lower coefficient of friction (COF). Electrochemical analysis indicated superior corrosion resistance, particularly for Ti 33 Co 33 Cr 33 MPEA. With respect to biocompatibility, both MPEAs demonstrated excellent cell adhesion and proliferation properties. Cell viability improved significantly, increasing from the control (100%) to ∼105% and 115% after 3 and 5 days, respectively. The combined results highlight the strong potential of these MPEAs for biomedical applications, offering a unique balance of high “density‐normalized” hardness, excellent corrosion resistance, and biological compatibility for future implant solutions.

Authors

Institutions

Publication Details

Journal
Advanced Healthcare Materials
Published
2026-10-30
DOI
https://doi.org/10.1002/adhm.71918
Primary Topic
High Entropy Alloys Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TiCoCr‐Based Multi‐Principal Element Alloys for Biomedical Applications

Ann Mary Mathew, Nitya Nand Gosvami, Koteswararao V. Rajulapati, Srikant Gollapudi et al.
5 links
Advanced Healthcare Materials
High Entropy Alloys Studies
article

TiCoCr‐Based Multi‐Principal Element Alloys for Biomedical Applications

Ann Mary Mathew, Nitya Nand Gosvami, Koteswararao V. Rajulapati, Srikant Gollapudi, Deepak Kumar Pattanayak, Ravishankar Suman, Nanda Kishore Karnam, Junaid Syed
article en

Abstract

ABSTRACT Next‐generation biomedical implants require materials with excellent wear resistance, corrosion resistance, and biocompatibility. This study developed two novel multi‐principal element alloys (MPEAs) based on the TiCoCr composition (equiatomic and non‐equiatomic) with ultra‐high hardness, excellent wear resistance, corrosion stability, and biocompatibility. The as‐cast microstructures revealed a multiphase combination of Ti‐rich hexagonal closed packing (HCP), C 14 Laves, and face‐centered cubic (FCC) phases. Upon heat treatment, equiatomic (Ti 33 Co 33 Cr 33 ) MPEA developed two major body‐centered (BCC) phases and a minor HCP phase, whereas heat treatment of non‐equiatomic (Ti 50 Co 25 Cr 25 ) MPEA revealed one BCC and C 14 Laves phase. The hardness of both MPEAs was slightly reduced after heat treatment. Wear and corrosion tests conducted in Hanks' balanced salt solution (HBSS) at 37°C on heat‐treated MPEAs demonstrated improved tribological and corrosion behavior, with reduced wear and a lower coefficient of friction (COF). Electrochemical analysis indicated superior corrosion resistance, particularly for Ti 33 Co 33 Cr 33 MPEA. With respect to biocompatibility, both MPEAs demonstrated excellent cell adhesion and proliferation properties. Cell viability improved significantly, increasing from the control (100%) to ∼105% and 115% after 3 and 5 days, respectively. The combined results highlight the strong potential of these MPEAs for biomedical applications, offering a unique balance of high “density‐normalized” hardness, excellent corrosion resistance, and biological compatibility for future implant solutions.

Advanced Healthcare Materials
Central Electrochemical Research Institute (IN), University of Hyderabad (IN), Indian Institute of Technology Delhi (IN), Academy of Scientific and Innovative Research (IN), Indian Institute of Technology Bhubaneswar (IN)
University of Hyderabad
Good health and well-being
Openalex Percentile: Top 23%
High Entropy Alloys Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon