Performance of intraoperative AI-assisted Label-Free Stimulated Raman Histology in Recurrent Brain Tumors

Abstract Background Therapy-induced tissue alterations complicate intraoperative diagnosis of recurrent CNS tumors. We evaluated stimulated Raman histology (SRH) combined with convolutional neural networks (CNNs) for rapid tumor detection and classification. Methods In this bicentric observational study, fresh tissue from patients undergoing resection or stereotactic biopsy for suspected recurrent CNS tumors was imaged with fiber-laser-based SRH. CNN1 performed binary tumor/non-tumor prediction and CNN2 histotype classification. CNN1 was evaluated against blinded neuropathologist SRH consensus and CNN2 against the final integrated histopathological diagnosis. Results Of 382 acquired SRH images, 262 images from 143 patients were included. CNN1 achieved an AUC of 0.975 (95% CI, 0.95–1.00) for tumor detection. An exploratory cohort-derived tumor probability threshold of ≥ 59 increased specificity from 70.7% to 92.0% while maintaining 95.2% sensitivity and identifying 71.4% of radiation necrosis samples. Among 212 images in treatment subgroup analysis, CNN1 accuracy did not differ significantly across prior-treatment groups (overall 90.1%; p = 0.080). CNN2 accuracy declined from 61.8% after surgery alone to 39.0% after surgery, radiotherapy, and medical treatment (χ²=6.04, p = 0.049). Multimodal therapy was independently associated with lower odds of correct CNN2 prediction (adjusted OR, 0.10 [95% CI, 0.02–0.39]; p = 0.001 and 0.04 [95% CI, 0.01–0.20]; p < 0.001). 120/382 images (31.5%) were of insufficient diagnostic quality; application of the quality control threshold would have rejected 84/120 (70.0%). Conclusions CNN1 maintained high tumor/non-tumor discrimination across treatment subgroups when image quality was sufficient, whereas CNN2 entity-classification performance declined with increasing treatment intensity. Reliable SRH-based diagnosis in recurrent tumors requires validated image-quality control measures and model adaptation to recurrent disease.

Authors

Institutions

Publication Details

Journal
Neuro-Oncology Advances
Published
2026-10-29
DOI
https://doi.org/10.1093/noajnl/vdag267
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of intraoperative AI-assisted Label-Free Stimulated Raman Histology in Recurrent Brain Tumors

Christian W. Freudiger, Pierre Scheffler, Roland Goldbrunner, Florian Khalid et al.
Neuro-Oncology Advances
Spectroscopy Techniques in Biomedical and Chemical Research
article

Performance of intraoperative AI-assisted Label-Free Stimulated Raman Histology in Recurrent Brain Tumors

Christian W. Freudiger, Pierre Scheffler, Roland Goldbrunner, Florian Khalid, David Reinecke, Gina Fürtjes, Volker Neuschmelting, Daniel F. Ruess, Nicolas Noel Neidert, Adrian Ion‐Mărgineanu, Niklas von Spreckelsen, Jakob Straehle, Thomas Stehlé, Zeynep Mercan, Anna-Katharina Meißner, Lili Leyer, Jürgen Beck, Nina Jung, Zachari Gueorguiev, Abdulkader Al Shughri, Claire Wang
article en

Abstract

Abstract Background Therapy-induced tissue alterations complicate intraoperative diagnosis of recurrent CNS tumors. We evaluated stimulated Raman histology (SRH) combined with convolutional neural networks (CNNs) for rapid tumor detection and classification. Methods In this bicentric observational study, fresh tissue from patients undergoing resection or stereotactic biopsy for suspected recurrent CNS tumors was imaged with fiber-laser-based SRH. CNN1 performed binary tumor/non-tumor prediction and CNN2 histotype classification. CNN1 was evaluated against blinded neuropathologist SRH consensus and CNN2 against the final integrated histopathological diagnosis. Results Of 382 acquired SRH images, 262 images from 143 patients were included. CNN1 achieved an AUC of 0.975 (95% CI, 0.95–1.00) for tumor detection. An exploratory cohort-derived tumor probability threshold of ≥ 59 increased specificity from 70.7% to 92.0% while maintaining 95.2% sensitivity and identifying 71.4% of radiation necrosis samples. Among 212 images in treatment subgroup analysis, CNN1 accuracy did not differ significantly across prior-treatment groups (overall 90.1%; p = 0.080). CNN2 accuracy declined from 61.8% after surgery alone to 39.0% after surgery, radiotherapy, and medical treatment (χ²=6.04, p = 0.049). Multimodal therapy was independently associated with lower odds of correct CNN2 prediction (adjusted OR, 0.10 [95% CI, 0.02–0.39]; p = 0.001 and 0.04 [95% CI, 0.01–0.20]; p < 0.001). 120/382 images (31.5%) were of insufficient diagnostic quality; application of the quality control threshold would have rejected 84/120 (70.0%). Conclusions CNN1 maintained high tumor/non-tumor discrimination across treatment subgroups when image quality was sufficient, whereas CNN2 entity-classification performance declined with increasing treatment intensity. Reliable SRH-based diagnosis in recurrent tumors requires validated image-quality control measures and model adaptation to recurrent disease.

Neuro-Oncology Advances
University of Freiburg (DE), University of Cologne (DE), University Medical Center Freiburg (DE), Invenio Imaging (United States) (US), University Hospital Cologne (DE), Westküstenkliniken Brunsbüttel und Heide gGmbH (DE)
Openalex Percentile: Top 20%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon