Accuracy of Computer-Assisted Navigation in Total Ankle Arthroplasty Surgery Using Computed Tomography: A Short Report

BACKGROUND: Computer-assisted navigation (CAN) offers dynamic intraoperative guidance in total ankle arthroplasty (TAA). Although laboratory data suggest superior precision, in vivo evidence is lacking. This study used weightbearing computed tomography (WBCT) to evaluate CAN accuracy of postoperative TAA implant position relative to the plan. We hypothesized that absolute discrepancies would be <3 mm or <3°. METHODS: Thirteen consecutive patients (November 2024-November 2025) underwent TAA using CAN. Preoperative computed tomography-based 3D models were used for templating. Postoperative WBCT scans were used to measure final implant seating, and computerized measurements were used to identify implant placement discrepancy. We analyzed absolute discrepancies between planned vs final postoperative positions. RESULTS: Tibial absolute discrepancies were within desired limits for varus/valgus (1.65° ± 1.43°), slope (1.87° ± 1.34°), and cut height (0.68 ± 0.62 mm) but not for axial rotation (3.97 ± 2.64). For the talus, varus/valgus (2.93° ± 1.86°) and cut height (0.66 ± 0.71 mm) absolute discrepancies were within desired limits. The increased talar slope deviation (3.90 ± 2.89) in the final position may be due to non-navigated implant impaction. CONCLUSION: Although discrepancies persisted in tibial rotational alignment and talar positioning, the low variability across measurements suggests that CAN may support accurate implant positioning. These short-term positioning accuracy findings support the utility of CAN as a potential tool for enhancing implant positioning reproducibility in TAA. LEVEL OF EVIDENCE: Level IV, case series.

Authors

Institutions

Publication Details

Journal
Foot & Ankle International
Published
2026-10-30
DOI
https://doi.org/10.1177/10711007261497273
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Computer-Assisted Navigation in Total Ankle Arthroplasty Surgery Using Computed Tomography: A Short Report

Taylor R. Rakauskas, Edward Thomas Haupt, François Boux de Casson, Seif El Masry et al.
2 links
Foot & Ankle International
Foot and Ankle Surgery
article

Accuracy of Computer-Assisted Navigation in Total Ankle Arthroplasty Surgery Using Computed Tomography: A Short Report

Taylor R. Rakauskas, Edward Thomas Haupt, François Boux de Casson, Seif El Masry, H Adám, Gabrielle M. Meli, Cyril Hamad, Cole Herbel
article en

Abstract

BACKGROUND: Computer-assisted navigation (CAN) offers dynamic intraoperative guidance in total ankle arthroplasty (TAA). Although laboratory data suggest superior precision, in vivo evidence is lacking. This study used weightbearing computed tomography (WBCT) to evaluate CAN accuracy of postoperative TAA implant position relative to the plan. We hypothesized that absolute discrepancies would be <3 mm or <3°. METHODS: Thirteen consecutive patients (November 2024-November 2025) underwent TAA using CAN. Preoperative computed tomography-based 3D models were used for templating. Postoperative WBCT scans were used to measure final implant seating, and computerized measurements were used to identify implant placement discrepancy. We analyzed absolute discrepancies between planned vs final postoperative positions. RESULTS: Tibial absolute discrepancies were within desired limits for varus/valgus (1.65° ± 1.43°), slope (1.87° ± 1.34°), and cut height (0.68 ± 0.62 mm) but not for axial rotation (3.97 ± 2.64). For the talus, varus/valgus (2.93° ± 1.86°) and cut height (0.66 ± 0.71 mm) absolute discrepancies were within desired limits. The increased talar slope deviation (3.90 ± 2.89) in the final position may be due to non-navigated implant impaction. CONCLUSION: Although discrepancies persisted in tibial rotational alignment and talar positioning, the low variability across measurements suggests that CAN may support accurate implant positioning. These short-term positioning accuracy findings support the utility of CAN as a potential tool for enhancing implant positioning reproducibility in TAA. LEVEL OF EVIDENCE: Level IV, case series.

Foot & Ankle International
Mayo Clinic in Florida (US)
Good health and well-being
Openalex Percentile: Top 10%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon