Residual Current Waveform Identification Based on Gaussian Filtering and Time-Frequency Analysis

Abstract With the continuous evolution of smart-grid technologies and electrical equipment, the waveform of the residual current has become increasingly diverse under complex operating conditions. Conventional residual current protection strategies generally rely on the root-mean-square (RMS) value for fault diagnosis, which only identifies the occurrence of residual current while lacking the capability to effectively distinguish among different types of residual current waveform. Herein, this paper proposes a method which uses Gaussian filtering and condition-triggered hierarchical time-frequency analysis to identify the residual current waveform. The sampled signals are first preprocessed using an adaptive Gaussian filter (AGF) to suppress noise, followed by temporal feature extraction and decision. If time-domain evaluation results are ambiguous, frequency-domain information is further incorporated as supplementary discriminative evidence, unlike conventional fusion approaches that apply both time- and frequency-domain analyses to all signals. Experimental results reveal that the adaptive Gaussian filter method provides excellent denoising performance across various types of residual current signals, achieving a signal-to-noise ratio (SNR) improvement of approximately 8-10 dB. Compared with the schemes based either on time- or frequency-domain analysis, the proposed time-frequency fusion approach achieves the best overall identification performance after filtering, with accuracies for double-pulse DC waveform reaching 97.3% and others approaching 100%. All of these findings confirm that the proposed method is capable of significantly boosting the identification accuracy of complex residual current waveforms while maintaining low computational complexity, which is thus highly promising to offer an efficient, robust and practically applicable solution for the leakage protection and even predictive maintenance in modern power system.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-10-29
DOI
https://doi.org/10.1088/1361-6501/aebb22
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Residual Current Waveform Identification Based on Gaussian Filtering and Time-Frequency Analysis

Zhenghong Qian, Zhe Sheng, Ru Bai, Li MingZe et al.
4 links
Measurement Science and Technology
Electrical Fault Detection and Protection
article

Residual Current Waveform Identification Based on Gaussian Filtering and Time-Frequency Analysis

Zhenghong Qian, Zhe Sheng, Ru Bai, Li MingZe, Qiqi Chen, Xiumei Li, Juan Meng, Yucheng Sun
article en

Abstract

Abstract With the continuous evolution of smart-grid technologies and electrical equipment, the waveform of the residual current has become increasingly diverse under complex operating conditions. Conventional residual current protection strategies generally rely on the root-mean-square (RMS) value for fault diagnosis, which only identifies the occurrence of residual current while lacking the capability to effectively distinguish among different types of residual current waveform. Herein, this paper proposes a method which uses Gaussian filtering and condition-triggered hierarchical time-frequency analysis to identify the residual current waveform. The sampled signals are first preprocessed using an adaptive Gaussian filter (AGF) to suppress noise, followed by temporal feature extraction and decision. If time-domain evaluation results are ambiguous, frequency-domain information is further incorporated as supplementary discriminative evidence, unlike conventional fusion approaches that apply both time- and frequency-domain analyses to all signals. Experimental results reveal that the adaptive Gaussian filter method provides excellent denoising performance across various types of residual current signals, achieving a signal-to-noise ratio (SNR) improvement of approximately 8-10 dB. Compared with the schemes based either on time- or frequency-domain analysis, the proposed time-frequency fusion approach achieves the best overall identification performance after filtering, with accuracies for double-pulse DC waveform reaching 97.3% and others approaching 100%. All of these findings confirm that the proposed method is capable of significantly boosting the identification accuracy of complex residual current waveforms while maintaining low computational complexity, which is thus highly promising to offer an efficient, robust and practically applicable solution for the leakage protection and even predictive maintenance in modern power system.

Measurement Science and Technology
Hangzhou Normal University (CN), Hangzhou Dianzi University (CN)
National Natural Science Foundation of China, Hangzhou Normal University, Natural Science Foundation of Zhejiang Province
Openalex Percentile: Top 24%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon