Anti-icing strategy and power requirement of ferromagnetic sleeves for overhead transmission lines under icing load constraints

Abstract In transmission line anti-icing applications, self-heating ferromagnetic sleeves can achieve passive heating through hysteresis and eddy current losses induced by alternating current magnetic fields. However, full-length installation significantly increases the conductor mechanical load, requiring a coordinated design between antiicing thermal performance and structural safety. In this study, an LGJ-400/35 conductor is selected as the research object, and a coupled thermal-fluid numerical model of the conductor-ferromagnetic sleeve system is established. The effectiveness of the ferromagnetic sleeve is first verified by comparing the temperature distributions of sleeved and bare conductors under identical conditions, demonstrating that the sleeve can significantly increase the conductor surface temperature and form a local effective anti-icing length. Under the constraint that the total sleeve mass per unit length does not exceed the equivalent design icing load, the minimum installation spacing ensuring mechanical safety in the light icing zone, moderate icing zone, and heavy icing zone is determined to be 0.43 m, 0.26 m, and 0.18 m, respectively. Furthermore, under a fixed operating current of 500 A, using the conductor midpoint temperature criterion (T mid > 0.5 ℃), the anti-icing performance boundary is evaluated for different spacing configurations. The results show that the maximum tolerable wind speeds are 4 m/s, 6 m/s, and 8 m/s for the three icing zones, respectively, indicating that reducing the spacing enhances anti-icing capability through thermal superposition. To address the limitation of fixed sleeve power under higher wind speed conditions, the required massspecific heating power of the sleeve is further inversely determined for different icing zones under their design wind speeds, yielding values within the range of 42-53 W/kg.The results indicate that the anti-icing performance of ferromagnetic sleeves is jointly governed by mechanical load constraints, installation spacing, and convective heat transfer conditions. By integrating load constraint, performance boundary evaluation, and power requirement determination,

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2026-10-29
DOI
https://doi.org/10.1088/2631-8695/aebb92
Primary Topic
Icing and De-icing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anti-icing strategy and power requirement of ferromagnetic sleeves for overhead transmission lines under icing load constraints

Maoqiang Bi, Qianqiu Shao, Hao Yang, Songhai Fan et al.
1 links
Engineering Research Express
Icing and De-icing Technologies
article

Anti-icing strategy and power requirement of ferromagnetic sleeves for overhead transmission lines under icing load constraints

Maoqiang Bi, Qianqiu Shao, Hao Yang, Songhai Fan, Chuanlin Xie, Haolin Su
article en

Abstract

Abstract In transmission line anti-icing applications, self-heating ferromagnetic sleeves can achieve passive heating through hysteresis and eddy current losses induced by alternating current magnetic fields. However, full-length installation significantly increases the conductor mechanical load, requiring a coordinated design between antiicing thermal performance and structural safety. In this study, an LGJ-400/35 conductor is selected as the research object, and a coupled thermal-fluid numerical model of the conductor-ferromagnetic sleeve system is established. The effectiveness of the ferromagnetic sleeve is first verified by comparing the temperature distributions of sleeved and bare conductors under identical conditions, demonstrating that the sleeve can significantly increase the conductor surface temperature and form a local effective anti-icing length. Under the constraint that the total sleeve mass per unit length does not exceed the equivalent design icing load, the minimum installation spacing ensuring mechanical safety in the light icing zone, moderate icing zone, and heavy icing zone is determined to be 0.43 m, 0.26 m, and 0.18 m, respectively. Furthermore, under a fixed operating current of 500 A, using the conductor midpoint temperature criterion (T mid > 0.5 ℃), the anti-icing performance boundary is evaluated for different spacing configurations. The results show that the maximum tolerable wind speeds are 4 m/s, 6 m/s, and 8 m/s for the three icing zones, respectively, indicating that reducing the spacing enhances anti-icing capability through thermal superposition. To address the limitation of fixed sleeve power under higher wind speed conditions, the required massspecific heating power of the sleeve is further inversely determined for different icing zones under their design wind speeds, yielding values within the range of 42-53 W/kg.The results indicate that the anti-icing performance of ferromagnetic sleeves is jointly governed by mechanical load constraints, installation spacing, and convective heat transfer conditions. By integrating load constraint, performance boundary evaluation, and power requirement determination,

Engineering Research Express
Chongqing University of Technology (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 19%
Icing and De-icing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon