Influence of pump-probe beam offset and modulation frequency on photothermal deflection spectroscopy signals in liquid sensing: a combined theoretical and experimental study

Photothermal deflection spectroscopy (PTD) measures optical absorption through the thermal response induced by a modulated pump beam. In an attenuated total reflection (ATR) configuration, the probe beam undergoes total internal reflection at the ATR–liquid interface, while the pump enters the adjacent liquid at normal incidence. Optical absorption produces refractive-index gradients and thermoelastic deformation that alter the direction of the reflected probe beam. The measured signal therefore depends on the lateral position at which the probe samples the heated region. Here we investigate this dependence using a three-dimensional finite-element model and an ATR-based PTD system. The model describes heat diffusion in the liquid and ATR crystal and calculates the resulting refractive-index gradient, surface deformation, and probe beam deflection. The calculated deflection is zero when the pump and probe beams overlap and reaches a maximum at a finite lateral offset, where the spatial gradients are largest. Measurements reproduce this behavior. For pump and probe radii of 300 μm and 150 μm, respectively, the maximum deflection occurs at an offset of approximately 280 μm. The signal also changes sign as the pump crosses the probe position. Increasing the modulation frequency reduces both the deflection amplitude and its spatial range. These results identify pump–probe offset and modulation frequency as important parameters for the alignment and interpretation of ATR-based PTD measurements.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2026-11-18
DOI
https://doi.org/10.1364/oe.619846
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Influence of pump-probe beam offset and modulation frequency on photothermal deflection spectroscopy signals in liquid sensing: a combined theoretical and experimental study

Bernhard Lendl, Liam O’Faoláin, Nelson Astrath, Gabriel Oliveira et al.
Optics Express
Thermography and Photoacoustic Techniques
article

Influence of pump-probe beam offset and modulation frequency on photothermal deflection spectroscopy signals in liquid sensing: a combined theoretical and experimental study

Bernhard Lendl, Liam O’Faoláin, Nelson Astrath, Gabriel Oliveira, Sebin Binu, Dominik Kau-Wacht
article en

Abstract

Photothermal deflection spectroscopy (PTD) measures optical absorption through the thermal response induced by a modulated pump beam. In an attenuated total reflection (ATR) configuration, the probe beam undergoes total internal reflection at the ATR–liquid interface, while the pump enters the adjacent liquid at normal incidence. Optical absorption produces refractive-index gradients and thermoelastic deformation that alter the direction of the reflected probe beam. The measured signal therefore depends on the lateral position at which the probe samples the heated region. Here we investigate this dependence using a three-dimensional finite-element model and an ATR-based PTD system. The model describes heat diffusion in the liquid and ATR crystal and calculates the resulting refractive-index gradient, surface deformation, and probe beam deflection. The calculated deflection is zero when the pump and probe beams overlap and reaches a maximum at a finite lateral offset, where the spatial gradients are largest. Measurements reproduce this behavior. For pump and probe radii of 300 μm and 150 μm, respectively, the maximum deflection occurs at an offset of approximately 280 μm. The signal also changes sign as the pump crosses the probe position. Increasing the modulation frequency reduces both the deflection amplitude and its spatial range. These results identify pump–probe offset and modulation frequency as important parameters for the alignment and interpretation of ATR-based PTD measurements.

Optics ExpressVol. 34(24)
Universidade Estadual de Maringá (BR), TU Wien (AT), Munster Technological University (IE), Tyndall National Institute (IE)
Österreichische Nationalstiftung für Forschung, Technologie und Entwicklung, Austrian Science Fund, Fundação Araucária, Christian Doppler Forschungsgesellschaft
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon