Green SPE–Spectrophotometric Determination of Trace Atrazine in Environmental and Agricultural Matrices

Abstract A sensitive, selective, and cost-effective analytical method integrating solid-phase extraction (SPE) with visible-region spectrophotometry was developed and validated for the quantitative determination of the s-triazine herbicide atrazine. The method is based on the reaction of atrazine with pyridine to form a quaternary pyridinium halide, which undergoes carbinol-base formation and heterocyclic ring cleavage under alkaline conditions, releasing glutaconic dialdehyde. Subsequent condensation of the dialdehyde with *p*-amino acetanilide produces a stable yellow-orange polymethine chromogen, which was quantified at 420 nm following preconcentration on a C18 SPE cartridge. The method exhibited excellent linearity over the concentration range of 0.5–6.5 µg mL⁻¹, with a molar absorptivity of 6.16 × 10⁵ L mol⁻¹ cm⁻¹ and a Sandell sensitivity of 0.00035 µg cm⁻². The SPE procedure provided a tenfold enrichment factor and improved the analytical sensitivity, affording a limit of detection (LOD) of 0.048 µg mL⁻¹ and a limit of quantification (LOQ) of 0.146 µg mL⁻¹. The method demonstrated good precision, with intra-day relative standard deviation (RSD) values below 1.5%. Analytical validation was performed in accordance with ICH Q2(R2) guidelines, covering accuracy, precision, linearity, and robustness. The environmental performance of the method was further assessed using the AGREE and Analytical Eco-Scale metrics, both of which indicated a favourable green analytical profile compared with conventional chromatographic approaches. The practical applicability of the method was demonstrated in fortified plant, soil, water, and grain yielding recoveries of 90.0–98.8% with RSD values below 3%. The combination of high sensitivity, low instrumentation requirements, satisfactory analytical performance, and favourable environmental characteristics makes the proposed method a promising alternative to LC–MS/MS and GC–ECD for routine atrazine residue monitoring, particularly in resource-limited laboratories.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-10-29
DOI
https://doi.org/10.21203/rs.3.rs-11228063/v1
Primary Topic
Pesticide Residue Analysis and Safety
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Green SPE–Spectrophotometric Determination of Trace Atrazine in Environmental and Agricultural Matrices

Manoj Kumar Banjare, Deshmukh Manisha, Bhupendra Singh Banjare, Prachi Parmar Nimje et al.
Research Square
Pesticide Residue Analysis and Safety
preprint

Green SPE–Spectrophotometric Determination of Trace Atrazine in Environmental and Agricultural Matrices

Manoj Kumar Banjare, Deshmukh Manisha, Bhupendra Singh Banjare, Prachi Parmar Nimje, Sunita Savaria
preprint en

Abstract

Abstract A sensitive, selective, and cost-effective analytical method integrating solid-phase extraction (SPE) with visible-region spectrophotometry was developed and validated for the quantitative determination of the s-triazine herbicide atrazine. The method is based on the reaction of atrazine with pyridine to form a quaternary pyridinium halide, which undergoes carbinol-base formation and heterocyclic ring cleavage under alkaline conditions, releasing glutaconic dialdehyde. Subsequent condensation of the dialdehyde with *p*-amino acetanilide produces a stable yellow-orange polymethine chromogen, which was quantified at 420 nm following preconcentration on a C18 SPE cartridge. The method exhibited excellent linearity over the concentration range of 0.5–6.5 µg mL⁻¹, with a molar absorptivity of 6.16 × 10⁵ L mol⁻¹ cm⁻¹ and a Sandell sensitivity of 0.00035 µg cm⁻². The SPE procedure provided a tenfold enrichment factor and improved the analytical sensitivity, affording a limit of detection (LOD) of 0.048 µg mL⁻¹ and a limit of quantification (LOQ) of 0.146 µg mL⁻¹. The method demonstrated good precision, with intra-day relative standard deviation (RSD) values below 1.5%. Analytical validation was performed in accordance with ICH Q2(R2) guidelines, covering accuracy, precision, linearity, and robustness. The environmental performance of the method was further assessed using the AGREE and Analytical Eco-Scale metrics, both of which indicated a favourable green analytical profile compared with conventional chromatographic approaches. The practical applicability of the method was demonstrated in fortified plant, soil, water, and grain yielding recoveries of 90.0–98.8% with RSD values below 3%. The combination of high sensitivity, low instrumentation requirements, satisfactory analytical performance, and favourable environmental characteristics makes the proposed method a promising alternative to LC–MS/MS and GC–ECD for routine atrazine residue monitoring, particularly in resource-limited laboratories.

Research Square
Shri Shankaracharya Professional University (IN)
Clean water and sanitation
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon