Characteristics of Indoor Environmental Conditions and Air Quality in Selected Schools in Northern Gyeonggi Province, South Korea: Comparisons by Space Type and School Level

Background: Indoor environmental conditions and air quality in schools can vary by classroom type and school level, but comparative assessments remain limited.Objectives: This study evaluated indoor environmental conditions and air quality in selected schools in northern Gyeonggi Province, South Korea, focusing on differences by classroom type and school level.Methods: A cross-sectional survey was conducted at 26 schools (15 elementary, six middle, and five high schools) from March 23 to April 9, 2026.Physical environmental parameters, particulate matter (PM 10 and PM 2.5 ), carbon dioxide (CO 2 ), total airborne bacteria (TBC), formaldehyde (HCHO), and volatile organic compounds (VOCs) were measured.Classroom-type and school-level differences were assessed using the Wilcoxon signed-rank and Kruskal-Wallis tests, respectively.Results: Significant differences between general and special-purpose classrooms were observed for noise, PM 10 , and HCHO (p<0.05).Illuminance also differed significantly between classroom types, although the differences in mean values were less than 1%, indicating limited practical magnitude.Mean HCHO concentrations were 7.36 µg/m 3 in general classrooms and 13.58 µg/m 3 in special-purpose classrooms, representing a 1.85-fold difference.The mean TVOC concentration was 130.82 µg/m 3 in the surveyed special-purpose classrooms.School-level differences were significant only for illuminance in special-purpose classrooms (p<0.05).Conclusions: Significant classroom-type differences were observed for selected indoor environmental and air quality parameters, whereas school-level differences were limited.These findings suggest that indoor environmental assessments of schools should consider classroom type and pollutant concentration distributions in addition to compliance with guideline values.

Authors

Institutions

Publication Details

Journal
Korean Journal of Environmental Health Sciences
Published
2026-10-30
DOI
https://doi.org/10.5668/jehs.2026.52.5.492
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characteristics of Indoor Environmental Conditions and Air Quality in Selected Schools in Northern Gyeonggi Province, South Korea: Comparisons by Space Type and School Level

SungChul Seo, Su-Jin Choi, Hyeonseo Kim, Jinseo Kim et al.
Korean Journal of Environmental Health Sciences
Indoor Air Quality and Microbial Exposure
article

Characteristics of Indoor Environmental Conditions and Air Quality in Selected Schools in Northern Gyeonggi Province, South Korea: Comparisons by Space Type and School Level

SungChul Seo, Su-Jin Choi, Hyeonseo Kim, Jinseo Kim, Joon-sig Jung
article en

Abstract

Background: Indoor environmental conditions and air quality in schools can vary by classroom type and school level, but comparative assessments remain limited.Objectives: This study evaluated indoor environmental conditions and air quality in selected schools in northern Gyeonggi Province, South Korea, focusing on differences by classroom type and school level.Methods: A cross-sectional survey was conducted at 26 schools (15 elementary, six middle, and five high schools) from March 23 to April 9, 2026.Physical environmental parameters, particulate matter (PM 10 and PM 2.5 ), carbon dioxide (CO 2 ), total airborne bacteria (TBC), formaldehyde (HCHO), and volatile organic compounds (VOCs) were measured.Classroom-type and school-level differences were assessed using the Wilcoxon signed-rank and Kruskal-Wallis tests, respectively.Results: Significant differences between general and special-purpose classrooms were observed for noise, PM 10 , and HCHO (p<0.05).Illuminance also differed significantly between classroom types, although the differences in mean values were less than 1%, indicating limited practical magnitude.Mean HCHO concentrations were 7.36 µg/m 3 in general classrooms and 13.58 µg/m 3 in special-purpose classrooms, representing a 1.85-fold difference.The mean TVOC concentration was 130.82 µg/m 3 in the surveyed special-purpose classrooms.School-level differences were significant only for illuminance in special-purpose classrooms (p<0.05).Conclusions: Significant classroom-type differences were observed for selected indoor environmental and air quality parameters, whereas school-level differences were limited.These findings suggest that indoor environmental assessments of schools should consider classroom type and pollutant concentration distributions in addition to compliance with guideline values.

Korean Journal of Environmental Health SciencesVol. 52(5)
Seokyeong University (KR)
Korea Environmental Industry and Technology Institute
Quality education
Openalex Percentile: Top 18%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon