Optimization of pediatric head CT protocols and dose reduction by radiology technologists in Cameroon, Benin, and Senegal

This study evaluates the role of radiology technologists in optimizing pediatric head computed tomography (CT) protocols and reducing radiation dose indices across three African countries (Cameroon, Senegal, and Benin), with the aim of promoting standardized CT practices in resource-limited settings. Data from 286 pediatric patients (<18 years) undergoing head CT were retrospectively analyzed across six scanner models (Siemens, Hitachi, Neusoft). To evaluate the technologist's role, we noted that local technologists manually set acquisition parameters due to the lack of dedicated pediatric protocols, with those trained in radiation protection primarily optimized dose levels by adjusting the tube voltage (kVp) based on patient age groups (≤1, 1-5, 5-10, and 10-15 years). Local dosimetric indices (CT dose index volume (CTDIvol) and dose length product (DLP)) were compiled and compared. Median CTDIvol values ranged from 14.4 to 22.8 mGy in Benin, 28.6 to 39.2 mGy in Senegal, and 24.7 to 53.9 mGy in Cameroon. Despite differences in scanner models and protocols, image quality was considered clinically acceptable, reflecting standard protocol practices where CT parameters are managed by technologists, and highlighting the potential value of closer regional collaboration among imaging professionals. These findings emphasize the importance of harmonizing imaging practices to strengthen dose optimization and patient radiation protection. This multi-country study demonstrates substantial variability in pediatric head CT dose indices across three African countries and highlights the importance of harmonized protocols, quality assurance, and continued training in dose optimization practices.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2026-10-29
DOI
https://doi.org/10.1093/rpd/ncag129
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of pediatric head CT protocols and dose reduction by radiology technologists in Cameroon, Benin, and Senegal

Serge Abogo, Odette Ngano Samba, Eddy Fotso Kamdem, A. J. Fotué et al.
1 links
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Optimization of pediatric head CT protocols and dose reduction by radiology technologists in Cameroon, Benin, and Senegal

Serge Abogo, Odette Ngano Samba, Eddy Fotso Kamdem, A. J. Fotué, Magatte Diagne, Séna Rufine Dossou, Brice Bertrand Foubi Kouam
article en

Abstract

This study evaluates the role of radiology technologists in optimizing pediatric head computed tomography (CT) protocols and reducing radiation dose indices across three African countries (Cameroon, Senegal, and Benin), with the aim of promoting standardized CT practices in resource-limited settings. Data from 286 pediatric patients (<18 years) undergoing head CT were retrospectively analyzed across six scanner models (Siemens, Hitachi, Neusoft). To evaluate the technologist's role, we noted that local technologists manually set acquisition parameters due to the lack of dedicated pediatric protocols, with those trained in radiation protection primarily optimized dose levels by adjusting the tube voltage (kVp) based on patient age groups (≤1, 1-5, 5-10, and 10-15 years). Local dosimetric indices (CT dose index volume (CTDIvol) and dose length product (DLP)) were compiled and compared. Median CTDIvol values ranged from 14.4 to 22.8 mGy in Benin, 28.6 to 39.2 mGy in Senegal, and 24.7 to 53.9 mGy in Cameroon. Despite differences in scanner models and protocols, image quality was considered clinically acceptable, reflecting standard protocol practices where CT parameters are managed by technologists, and highlighting the potential value of closer regional collaboration among imaging professionals. These findings emphasize the importance of harmonizing imaging practices to strengthen dose optimization and patient radiation protection. This multi-country study demonstrates substantial variability in pediatric head CT dose indices across three African countries and highlights the importance of harmonized protocols, quality assurance, and continued training in dose optimization practices.

Radiation Protection Dosimetry
Université de Yaoundé I (CM), Université de Dschang (CM), Hôpital Aristide Le Dantec (SN), Yaoundé General Hospital (CM), Institut Curie (FR)
Good health and well-being
Openalex Percentile: Top 13%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon