Field emission current measurements during high field conditioning of Nb and Ti-6Al-4V electrodes in cryogenic conditions

The maximum accelerating field achievable in both normal and superconducting cavities is limited by field emission and vacuum arcs. However, this limit can be extended with a conditioning process and significantly enhanced by operating at cryogenic temperatures. To better understand how vacuum arcs begin and how conditioning improves performance, consistent data across different materials and temperatures are needed. To support this effort, high-voltage tests were carried out on Nb and Ti-6Al-4V electrodes at low temperatures, demonstrating strong ability to withstand high electric fields. Nb electrodes reached fields of 149 MV / m , while Ti-6Al-4V could sustain electric fields up to 190 MV / m at 4 K with a breakdown rate less than 10 − 5 breakdowns / pulse . Ti-6Al-4V maintained high performance after reconditioning at room temperature, sustaining 150 MV / m . Field emission measurements enabled precise monitoring of surface evolution, especially under cryogenic conditions. High-quality I-V data obtained at cryogenic temperatures enabled accurate extraction of surface state in form of two parameters: field enhancement factor and emission area. Long-term conditioning showed a steady, exponential decrease in enhancement factor and a significant increase in emission area, suggesting a transition from sharp to blunt emitters. Interestingly, the product of enhancement factor and highest sustainable field was similar for both samples and nearly temperature-independent ∼ 7 GV / m . Regular field emission monitoring is proposed as a diagnostic tool for optimizing conditioning, with variations in the enhancement factor signaling approach to the material’s field limit.

Authors

Institutions

Publication Details

Journal
Physical Review Applied
Published
2026-11-23
DOI
https://doi.org/10.1103/7k3j-d7wz
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Field emission current measurements during high field conditioning of Nb and Ti-6Al-4V electrodes in cryogenic conditions

Andreas Kyritsakis, Iaroslava Profatilova, Mircea Coman, M. Jacewicz et al.
Physical Review Applied
Particle accelerators and beam dynamics
article

Field emission current measurements during high field conditioning of Nb and Ti-6Al-4V electrodes in cryogenic conditions

Andreas Kyritsakis, Iaroslava Profatilova, Mircea Coman, M. Jacewicz, Walter Wuensch, Sergio Calatroni
article en

Abstract

The maximum accelerating field achievable in both normal and superconducting cavities is limited by field emission and vacuum arcs. However, this limit can be extended with a conditioning process and significantly enhanced by operating at cryogenic temperatures. To better understand how vacuum arcs begin and how conditioning improves performance, consistent data across different materials and temperatures are needed. To support this effort, high-voltage tests were carried out on Nb and Ti-6Al-4V electrodes at low temperatures, demonstrating strong ability to withstand high electric fields. Nb electrodes reached fields of 149 MV / m , while Ti-6Al-4V could sustain electric fields up to 190 MV / m at 4 K with a breakdown rate less than 10 − 5 breakdowns / pulse . Ti-6Al-4V maintained high performance after reconditioning at room temperature, sustaining 150 MV / m . Field emission measurements enabled precise monitoring of surface evolution, especially under cryogenic conditions. High-quality I-V data obtained at cryogenic temperatures enabled accurate extraction of surface state in form of two parameters: field enhancement factor and emission area. Long-term conditioning showed a steady, exponential decrease in enhancement factor and a significant increase in emission area, suggesting a transition from sharp to blunt emitters. Interestingly, the product of enhancement factor and highest sustainable field was similar for both samples and nearly temperature-independent ∼ 7 GV / m . Regular field emission monitoring is proposed as a diagnostic tool for optimizing conditioning, with variations in the enhancement factor signaling approach to the material’s field limit.

Physical Review AppliedVol. 26(5)
Uppsala University (SE), University of Tartu (EE), European Organization for Nuclear Research (CH)
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon