Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques

OBJECTIVE: This study reviewed the early shifts in low-frequency hearing for cochlear implant (CI) hearing preservation candidates who underwent cochlear implantation using either manual or robotic-assisted insertion of the electrode array and evaluated possible contributing factors such as angular insertion depth (AID), preoperative hearing, and age. PATIENTS: Adult CI hearing preservation candidates (≥18 yr, ≤70 dB HL at 250 Hz) who underwent cochlear implantation with a straight electrode array through a manual or robotic-assisted insertion. MAIN OUTCOME MEASURES: A low-frequency pure tone average (125, 250, and 500 Hz) was calculated from the unaided thresholds obtained preoperatively and within the initial weeks following surgery. Queried data included impedance values measured intraoperatively and at CI activation, and the AID of the most apical electrode contact. RESULTS: Of 120 cases (66 females), 92 underwent manual insertion (median age = 69.0 yrs, interquartile range = 63.5 to 79.0) and 28 underwent robotic-assisted insertion (median age = 67.0 yrs, interquartile range = 60.9 to 76.3). Patients received either a 23, 24, 26, 28, or 31.5 mm electrode array. Significantly less low-frequency pure tone average shift was observed for robotic-assisted insertions (P = 0.028), shallower AIDs (P = 0.010), and younger patients (P = 0.001). There was a significant interaction between insertion group and AID (P = 0.010), with robotic-assisted insertion demonstrating better hearing preservation at AIDs exceeding 490°. Impedance values did not differ significantly between insertion groups intraoperatively or at CI activation. CONCLUSIONS: Robotic-assisted electrode array insertion may support better early hearing preservation compared with manual insertions, particularly for patients with electrode arrays placed at deeper AIDs. LEVEL OF EVIDENCE: Level IV; retrospective cohort study.

Authors

Institutions

Publication Details

Journal
Otology & Neurotology
Published
2026-10-29
DOI
https://doi.org/10.1097/mao.0000000000005108
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques

Margaret T. Dillon, Matthew M. Dedmon, Nicholas J. Thompson, Carlos A. Perez-Heydrich et al.
6 links
Otology & Neurotology
Hearing Loss and Rehabilitation
article

Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques

Margaret T. Dillon, Matthew M. Dedmon, Nicholas J. Thompson, Carlos A. Perez-Heydrich, Anne Morgan Selleck, Margaret E. Richter, Elena Quinonez Del Cid, Samantha P Scharf, Kevin M. Brown, Madison Elizabeth Broome
article en

Abstract

OBJECTIVE: This study reviewed the early shifts in low-frequency hearing for cochlear implant (CI) hearing preservation candidates who underwent cochlear implantation using either manual or robotic-assisted insertion of the electrode array and evaluated possible contributing factors such as angular insertion depth (AID), preoperative hearing, and age. PATIENTS: Adult CI hearing preservation candidates (≥18 yr, ≤70 dB HL at 250 Hz) who underwent cochlear implantation with a straight electrode array through a manual or robotic-assisted insertion. MAIN OUTCOME MEASURES: A low-frequency pure tone average (125, 250, and 500 Hz) was calculated from the unaided thresholds obtained preoperatively and within the initial weeks following surgery. Queried data included impedance values measured intraoperatively and at CI activation, and the AID of the most apical electrode contact. RESULTS: Of 120 cases (66 females), 92 underwent manual insertion (median age = 69.0 yrs, interquartile range = 63.5 to 79.0) and 28 underwent robotic-assisted insertion (median age = 67.0 yrs, interquartile range = 60.9 to 76.3). Patients received either a 23, 24, 26, 28, or 31.5 mm electrode array. Significantly less low-frequency pure tone average shift was observed for robotic-assisted insertions (P = 0.028), shallower AIDs (P = 0.010), and younger patients (P = 0.001). There was a significant interaction between insertion group and AID (P = 0.010), with robotic-assisted insertion demonstrating better hearing preservation at AIDs exceeding 490°. Impedance values did not differ significantly between insertion groups intraoperatively or at CI activation. CONCLUSIONS: Robotic-assisted electrode array insertion may support better early hearing preservation compared with manual insertions, particularly for patients with electrode arrays placed at deeper AIDs. LEVEL OF EVIDENCE: Level IV; retrospective cohort study.

Otology & Neurotology
University of North Carolina at Chapel Hill (US)
Good health and well-being
Openalex Percentile: Top 14%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon