Analysis of Optic Nerve Stress, Strain, and Pressure in Human Eyes with Different Axial Lengths under Different G-force Levels at a Normal Intraocular Pressure of 20 mmHg

nerve stress, strain, pressure, human eyes, different axial lengths, different G-force levelsIn this study, we present a finite-element-based investigation of the biomechanical responses of the human eye under combined G-force loading and physiological intraocular pressure (IOP), with an emphasis on implications for ophthalmic sensing and measurement reliability.Threedimensional eye models with different axial lengths were constructed and imported into ANSYS to perform modal and transient dynamic analyses.Modal analysis revealed that an increase in axial length consistently reduced the natural frequencies across all vibration modes, while the corresponding mode shapes remained largely unchanged, indicating preserved structural deformation patterns despite geometric variation.Dynamic simulations were conducted by constraining the eyeball to displace only along the primary loading axis, with external acceleration gradually increased from 1 to 6G.Within a normal human IOP of 20 mmHg, the resulting stress, strain, and pressure distributions in the optic nerve were systematically analyzed for eyes with different axial lengths.The results demonstrate that axial length significantly affects the magnitude and spatial distribution of optic nerve mechanical responses under different G-force levels, suggesting a nonnegligible coupling effect between ocular geometry and external dynamic loading.From a sensing perspective, these findings provide quantitative mechanical indicators that are critical for the calibration, interpretation, and validation of ophthalmic pressure and strain-related sensors.The primary objective is to clarify how ocular axial length affects optic nerve mechanical responses under different G-force levels at a normal IOP.However, the analysis is limited to numerical simulations with simplified material properties and boundary conditions, without direct experimental validation.Future investigations will be focused on improving the biomechanical representation of ocular tissues

Authors

Institutions

Publication Details

Journal
Sensors and Materials
Published
2026-10-29
DOI
https://doi.org/10.18494/sam6274
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Optic Nerve Stress, Strain, and Pressure in Human Eyes with Different Axial Lengths under Different G-force Levels at a Normal Intraocular Pressure of 20 mmHg

Linda Yi-Chieh Poon, Peng-San Cheng, Chia-Wen Lee, Chao-Ming Hsu et al.
1 links
Sensors and Materials
Glaucoma and retinal disorders
article

Analysis of Optic Nerve Stress, Strain, and Pressure in Human Eyes with Different Axial Lengths under Different G-force Levels at a Normal Intraocular Pressure of 20 mmHg

Linda Yi-Chieh Poon, Peng-San Cheng, Chia-Wen Lee, Chao-Ming Hsu, Chia-Jui Chang, Cheng-Fu Yang
article en

Abstract

nerve stress, strain, pressure, human eyes, different axial lengths, different G-force levelsIn this study, we present a finite-element-based investigation of the biomechanical responses of the human eye under combined G-force loading and physiological intraocular pressure (IOP), with an emphasis on implications for ophthalmic sensing and measurement reliability.Threedimensional eye models with different axial lengths were constructed and imported into ANSYS to perform modal and transient dynamic analyses.Modal analysis revealed that an increase in axial length consistently reduced the natural frequencies across all vibration modes, while the corresponding mode shapes remained largely unchanged, indicating preserved structural deformation patterns despite geometric variation.Dynamic simulations were conducted by constraining the eyeball to displace only along the primary loading axis, with external acceleration gradually increased from 1 to 6G.Within a normal human IOP of 20 mmHg, the resulting stress, strain, and pressure distributions in the optic nerve were systematically analyzed for eyes with different axial lengths.The results demonstrate that axial length significantly affects the magnitude and spatial distribution of optic nerve mechanical responses under different G-force levels, suggesting a nonnegligible coupling effect between ocular geometry and external dynamic loading.From a sensing perspective, these findings provide quantitative mechanical indicators that are critical for the calibration, interpretation, and validation of ophthalmic pressure and strain-related sensors.The primary objective is to clarify how ocular axial length affects optic nerve mechanical responses under different G-force levels at a normal IOP.However, the analysis is limited to numerical simulations with simplified material properties and boundary conditions, without direct experimental validation.Future investigations will be focused on improving the biomechanical representation of ocular tissues

Sensors and MaterialsVol. 38(10)
Chaoyang University of Technology (TW), National University of Kaohsiung (TW), National Kaohsiung University of Science and Technology (TW), Xiamen Ocean Vocational College (CN)
National Science and Technology Council
Good health and well-being
Openalex Percentile: Top 9%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon