Standoff detection of carbon monoxide from the underground high explosive detonation in Physics Experiment 1-A using swept-wavelength ECQCL spectroscopy

Results are presented from a custom-built standoff infrared spectroscopy instrument used to detect above-ground CO generated in the Physics Experiment 1-A test, in which 13 580 kg of high explosives were detonated in an enclosed underground chamber. The instrument used a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) scanned over a wavenumber (wavelength) region of 1965–2290 cm−1 (4.37–5.09 μm) at a 100 Hz rate. The system was configured for standoff open-path measurements with a 223 m distance between the swept-ECQCL instrument and a retro-reflecting mirror, with the beam passing directly above a vent connected to the underground tunnel complex containing the detonation. Spectral fitting provided column densities of CO, CO2, H2O, and N2O, and a spectroscopic temperature, at 1 s intervals over a continuous 27-day period after detonation. The results showed that CO detected above ambient levels throughout most of this period, with a 5 orders-of-magnitude measurement dynamic range. Statistical analysis of the time-resolved CO signal shows a large fraction of low-magnitude and short-duration CO plume fluctuations. Measurement precision/sensitivity for CO detection is characterized to be 0.20 ppm × m at 1 s averaging, improving to 0.05 ppm × m when averaged to 100 s, corresponding to average CO concentrations of 450 ppt at 1 s and 110 ppt at 100 s. The combination of continuous high-speed measurements at high-precision and with high dynamic range provided by the swept-ECQCL sensor provides a valuable capability for detection and characterization of transient plume sources released into the atmosphere.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2026-10-28
DOI
https://doi.org/10.1063/5.0358259
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standoff detection of carbon monoxide from the underground high explosive detonation in Physics Experiment 1-A using swept-wavelength ECQCL spectroscopy

Mark C. Phillips, Bruce E. Bernacki, S. S. Harilal, the PE1 Experiment Team
Journal of Applied Physics
Spectroscopy and Laser Applications
article

Standoff detection of carbon monoxide from the underground high explosive detonation in Physics Experiment 1-A using swept-wavelength ECQCL spectroscopy

Mark C. Phillips, Bruce E. Bernacki, S. S. Harilal, the PE1 Experiment Team
article en

Abstract

Results are presented from a custom-built standoff infrared spectroscopy instrument used to detect above-ground CO generated in the Physics Experiment 1-A test, in which 13 580 kg of high explosives were detonated in an enclosed underground chamber. The instrument used a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) scanned over a wavenumber (wavelength) region of 1965–2290 cm−1 (4.37–5.09 μm) at a 100 Hz rate. The system was configured for standoff open-path measurements with a 223 m distance between the swept-ECQCL instrument and a retro-reflecting mirror, with the beam passing directly above a vent connected to the underground tunnel complex containing the detonation. Spectral fitting provided column densities of CO, CO2, H2O, and N2O, and a spectroscopic temperature, at 1 s intervals over a continuous 27-day period after detonation. The results showed that CO detected above ambient levels throughout most of this period, with a 5 orders-of-magnitude measurement dynamic range. Statistical analysis of the time-resolved CO signal shows a large fraction of low-magnitude and short-duration CO plume fluctuations. Measurement precision/sensitivity for CO detection is characterized to be 0.20 ppm × m at 1 s averaging, improving to 0.05 ppm × m when averaged to 100 s, corresponding to average CO concentrations of 450 ppt at 1 s and 110 ppt at 100 s. The combination of continuous high-speed measurements at high-precision and with high dynamic range provided by the swept-ECQCL sensor provides a valuable capability for detection and characterization of transient plume sources released into the atmosphere.

Journal of Applied PhysicsVol. 140(16)
Lawrence Livermore National Laboratory (US), University of Arizona (US), Pacific Northwest National Laboratory (US)
Openalex Percentile: Top 27%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon