Construct Validity of Frontier Large Language Models on 4 Spanish Health Professions Specialty-Access Examinations (MIR, EIR, PIR, and FIR): Cross-Sectional Benchmarking and Psychometric Study

Abstract Background Large language models (LLMs) achieve high scores on health-professions examinations. Whether these scores support the same interpretations as human scores remains uncertain. Spain uses parallel multiple-choice examinations for entry to specialty training in medicine (Médico Interno Residente [MIR]), nursing (Enfermero Interno Residente [EIR]), psychology (Psicólogo Interno Residente [PIR]), and pharmacy (Farmacéutico Interno Residente [FIR]). Objective Using the January 2026 MIR, EIR, PIR, and FIR examinations, this study aimed to quantify the correspondence between human and LLM item facility and to describe model accuracy, distractor selection, and performance associated with measured surface features. Methods We evaluated 839 valid items using 12 configurations: GPT-5.2 at 3 reasoning efforts and Claude Opus, Sonnet, and Haiku 4.5 (Anthropic), each under neutral and expert prompts, with one run per configuration. The primary measure was the Spearman correlation (ρ) between human and machine facility on 828 complete paired items. We examined sensitivity to panel composition, scoring, pooling, and assumed reliability; compared distractor choices with a post hoc plausibility-weighted baseline; and evaluated a surface-feature classifier. Image analyses distinguished supplied from withheld images. An exploratory LLM-judge audit assessed generated explanations. Bootstrap CIs resample items or, for distractor concordance, error events; they exclude run-to-run uncertainty. Results The highest pooled accuracy was 94.8% (795/839); all 12 configurations answered 668 of 828 paired items correctly (80.7%). Scores clustered near the ceiling among the strongest configurations. Human and machine facility correlated at 0.40 (95% CI 0.34-0.45), with estimates of 0.31 to 0.40 across panel definitions and 0.39 (95% CI 0.33-0.45) after exam-stratified pooling. The observed correlation was lower than predicted by a specified one-axis simulation with a uniform model advantage (0.63; predictive interval 0.59 to 0.66; P <.001). Among 672 model errors, dominant human-distractor selection differed from the plausibility-weighted baseline by –1.25 percentage points (95% CI –4.53 to 2.19), compatible with no difference. Surface-feature accuracy was 34.4% (289/839), similar to selecting the longest option (34.6%, 290/839). The adjusted association with model correctness was uncertain (odds ratio [OR] 0.87, 95% CI 0.72-1.04). Image-associated accuracy was lower both when images were supplied (OR 0.33, 95% CI 0.21-0.53) and when withheld (OR 0.11, 95% CI 0.08-0.16). Conclusions In this single 2026 cohort, high LLM scores coexisted with limited separation among the strongest configurations and moderate correspondence with human item difficulty. These findings caution against interpreting model scores as equivalent evidence of human competence. They do not establish clinical performance or invalidate the examinations for human candidates.

Authors

Institutions

Publication Details

Journal
JMIR Medical Education
Published
2026-10-29
DOI
https://doi.org/10.2196/106199
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Construct Validity of Frontier Large Language Models on 4 Spanish Health Professions Specialty-Access Examinations (MIR, EIR, PIR, and FIR): Cross-Sectional Benchmarking and Psychometric Study

Carlos Carazo-Casas, Manuel Carpio Salmerón, J Pavón, Clemente García-Hidalgo et al.
3 links
JMIR Medical Education
Artificial Intelligence in Healthcare and Education
article

Construct Validity of Frontier Large Language Models on 4 Spanish Health Professions Specialty-Access Examinations (MIR, EIR, PIR, and FIR): Cross-Sectional Benchmarking and Psychometric Study

Carlos Carazo-Casas, Manuel Carpio Salmerón, J Pavón, Clemente García-Hidalgo, Pau Benito, Beatriz Carratalá
article en

Abstract

Abstract Background Large language models (LLMs) achieve high scores on health-professions examinations. Whether these scores support the same interpretations as human scores remains uncertain. Spain uses parallel multiple-choice examinations for entry to specialty training in medicine (Médico Interno Residente [MIR]), nursing (Enfermero Interno Residente [EIR]), psychology (Psicólogo Interno Residente [PIR]), and pharmacy (Farmacéutico Interno Residente [FIR]). Objective Using the January 2026 MIR, EIR, PIR, and FIR examinations, this study aimed to quantify the correspondence between human and LLM item facility and to describe model accuracy, distractor selection, and performance associated with measured surface features. Methods We evaluated 839 valid items using 12 configurations: GPT-5.2 at 3 reasoning efforts and Claude Opus, Sonnet, and Haiku 4.5 (Anthropic), each under neutral and expert prompts, with one run per configuration. The primary measure was the Spearman correlation (ρ) between human and machine facility on 828 complete paired items. We examined sensitivity to panel composition, scoring, pooling, and assumed reliability; compared distractor choices with a post hoc plausibility-weighted baseline; and evaluated a surface-feature classifier. Image analyses distinguished supplied from withheld images. An exploratory LLM-judge audit assessed generated explanations. Bootstrap CIs resample items or, for distractor concordance, error events; they exclude run-to-run uncertainty. Results The highest pooled accuracy was 94.8% (795/839); all 12 configurations answered 668 of 828 paired items correctly (80.7%). Scores clustered near the ceiling among the strongest configurations. Human and machine facility correlated at 0.40 (95% CI 0.34-0.45), with estimates of 0.31 to 0.40 across panel definitions and 0.39 (95% CI 0.33-0.45) after exam-stratified pooling. The observed correlation was lower than predicted by a specified one-axis simulation with a uniform model advantage (0.63; predictive interval 0.59 to 0.66; P <.001). Among 672 model errors, dominant human-distractor selection differed from the plausibility-weighted baseline by –1.25 percentage points (95% CI –4.53 to 2.19), compatible with no difference. Surface-feature accuracy was 34.4% (289/839), similar to selecting the longest option (34.6%, 290/839). The adjusted association with model correctness was uncertain (odds ratio [OR] 0.87, 95% CI 0.72-1.04). Image-associated accuracy was lower both when images were supplied (OR 0.33, 95% CI 0.21-0.53) and when withheld (OR 0.11, 95% CI 0.08-0.16). Conclusions In this single 2026 cohort, high LLM scores coexisted with limited separation among the strongest configurations and moderate correspondence with human item difficulty. These findings caution against interpreting model scores as equivalent evidence of human competence. They do not establish clinical performance or invalidate the examinations for human candidates.

JMIR Medical EducationVol. 12
Hospital General Universitario Morales Meseguer (ES), Hospital Clínic de Barcelona (ES), Santa Lucía University General Hospital (ES), Barcelona Institute for Global Health (ES), Hospital Universitario Ramón y Cajal (ES)
Good health and well-being
Openalex Percentile: Top 20%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon