Comparative Study of Uniform and Nonuniform Waveguide Bragg Grating Sensors for Measuring Blood Glucose Concentration

Accurate monitoring of blood glucose concentration is highly importantcc for the diagnosis, treatment, and long-term management of diabetes. Although conventional electrochemical blood glucose sensors are widely applied in clinical practice, they generally suffer from inherent limitations such as susceptibility to electromagnetic interference, rapid decay of enzyme activity, and short service life. In this work, three optical waveguide Bragg grating (WBG) blood glucose sensors structures are designed and fabricated on a silicon-on-insulator (SOI) platform: a narrow-in/narrow-out bilateral uniform WBG, a narrow-in/narrow-out bilateral apodized WBG, and a narrow-in/wide-out bilateral uniform WBG. A stable glucose oxidase (GOD) biosensing layer is constructed on the grating surface via silane-coupling covalent immobilization to enable specific recognition and sensing of blood glucose molecules. The experimental results show that the narrow-in/wide-out bilateral uniform WBG sensor achieves the best overall performance, with a measured sensitivity of 169.598 nm/RIU in the concentration range of 0–2.4 mg/mL; the narrow-in/narrow-out bilateral uniform WBG sensor exhibits a measured sensitivity of 110 nm/RIU in the linear range of 0–3 mg/mL; and the narrow-in/narrow-out bilateral apodized WBG sensor reaches a measured sensitivity of 135.860 nm/RIU in the linear range of 0–2.3 mg/mL. All three devices demonstrate good anti-interference capability and stable operation over 8 h, and the fingertip blood test results agree well with those obtained using a commercial blood glucose meter. This work provides a feasible technical scheme and experimental evidence for the design of high-precision wearable photonic devices for continuous blood glucose monitoring.

Authors

Institutions

Publication Details

Published
2026-10-29
DOI
https://doi.org/10.1364/opticaopen.34808322.v1
Primary Topic
Advanced Fiber Optic Sensors
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Comparative Study of Uniform and Nonuniform Waveguide Bragg Grating Sensors for Measuring Blood Glucose Concentration

Ziying Niu, Enbang Li, Shida Zhang, Francisco Hernández-Ramírez et al.
2 links
Advanced Fiber Optic Sensors
preprint

Comparative Study of Uniform and Nonuniform Waveguide Bragg Grating Sensors for Measuring Blood Glucose Concentration

Ziying Niu, Enbang Li, Shida Zhang, Francisco Hernández-Ramírez, Yueting Yang, Jingxuan Zhao, Liyuan Yang, Sixun Chen, Lu Cao, MING Han, Hongqiang Li, Dongyang Liu, Cheng Zhang, Xiaolin Li, Jiahao Gu
preprint en

Abstract

Accurate monitoring of blood glucose concentration is highly importantcc for the diagnosis, treatment, and long-term management of diabetes. Although conventional electrochemical blood glucose sensors are widely applied in clinical practice, they generally suffer from inherent limitations such as susceptibility to electromagnetic interference, rapid decay of enzyme activity, and short service life. In this work, three optical waveguide Bragg grating (WBG) blood glucose sensors structures are designed and fabricated on a silicon-on-insulator (SOI) platform: a narrow-in/narrow-out bilateral uniform WBG, a narrow-in/narrow-out bilateral apodized WBG, and a narrow-in/wide-out bilateral uniform WBG. A stable glucose oxidase (GOD) biosensing layer is constructed on the grating surface via silane-coupling covalent immobilization to enable specific recognition and sensing of blood glucose molecules. The experimental results show that the narrow-in/wide-out bilateral uniform WBG sensor achieves the best overall performance, with a measured sensitivity of 169.598 nm/RIU in the concentration range of 0–2.4 mg/mL; the narrow-in/narrow-out bilateral uniform WBG sensor exhibits a measured sensitivity of 110 nm/RIU in the linear range of 0–3 mg/mL; and the narrow-in/narrow-out bilateral apodized WBG sensor reaches a measured sensitivity of 135.860 nm/RIU in the linear range of 0–2.3 mg/mL. All three devices demonstrate good anti-interference capability and stable operation over 8 h, and the fingertip blood test results agree well with those obtained using a commercial blood glucose meter. This work provides a feasible technical scheme and experimental evidence for the design of high-precision wearable photonic devices for continuous blood glucose monitoring.

Tianjin University (CN), Tiangong University (CN), University of Wollongong (AU), Tianjin Chest Hospital (CN)
National Natural Science Foundation of China, Natural Science Foundation of Tianjin City
Good health and well-being
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon