Improving prostate MRI quality assessment across diverse evaluators and institutional practice through a PI-QUAL v2 lecture: a pilot study

OBJECTIVE: To evaluate the impact of a prostate imaging quality (PI-QUAL) v2 lecture on the accuracy and inter-reader agreement of prostate MRI image-quality assessment among radiologists and technologists from diverse professional backgrounds and institutions, and to evaluate its role in institutional-level quality improvement through a quality control (QC) process. MATERIALS AND METHODS: Ten participants (five radiologists and five technologists) from five different hospitals independently evaluated 15 prostate MRIs before and after a standardized PI-QUAL v2 lecture. Reference scores were established by two experienced radiologists. Concordance with reference was assessed using accuracy and balanced accuracy. Inter-reader agreement was measured using percent agreement (PA) and Gwet's AC1. Subgroup analyses were conducted based on participant characteristics. For the quality assurance and QC (QA/QC), each center submitted 15 prostate MRIs before and after the lecture. Image quality was evaluated centrally to assess institutional improvement. RESULTS: Overall accuracy increased from 66.7% to 76.7%, and balanced accuracy increased from 62.9% to 84.2%; the mixed-effects model indicated significantly higher post-lecture accuracy (p = 0.038). Accuracy was also higher across all subgroups. Inter-reader agreement improved from PA 57.6% to 72.6% and Gwet's AC1 from 0.214 to 0.466. Through the QA/QC process, three centers initially failed to meet PI-QUAL v2 technical criteria. After feedback, all post-intervention scans achieved PI-QUAL v2 scores > 1. CONCLUSION: A structured PI-QUAL v2 lecture improved both the accuracy and inter-reader agreement of prostate MRI image-quality assessments among diverse evaluators. Incorporating QA/QC further enhanced institutional image quality. PI-QUAL v2 training is a feasible strategy for standardizing prostate MRI quality. KEY POINTS: Question Does a structured PI-QUAL v2 lecture for radiologists and technologists improve prostate MRI quality assessment performance and institutional imaging practice across institutions? Findings PI-QUAL v2 training improved accuracy (66.7% to 76.7%) and inter-reader agreement in prostate MRI quality assessment, while QA/QC feedback enhanced institutional imaging quality. Clinical relevance statement Structured PI-QUAL v2 education combined with quality assurance and quality control feedback improves evaluator consistency and institutional prostate MRI quality, facilitating standardized image-quality assessment and broader implementation of high-quality prostate MRI in clinical radiology.

Authors

Institutions

Publication Details

Journal
Insights into Imaging
Published
2026-10-29
DOI
https://doi.org/10.1186/s13244-026-02450-x
Primary Topic
Radiology practices and education
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving prostate MRI quality assessment across diverse evaluators and institutional practice through a PI-QUAL v2 lecture: a pilot study

Caroline M. Moore, Lei Shi, Feng Tianlu, Francesco Giganti et al.
5 links
Insights into Imaging
Radiology practices and education
article

Improving prostate MRI quality assessment across diverse evaluators and institutional practice through a PI-QUAL v2 lecture: a pilot study

Caroline M. Moore, Lei Shi, Feng Tianlu, Francesco Giganti, Xiaoxiao Zhang, CLARE M. ALLEN, 杨力铭, Gumuyang Zhang, Xu Wang, Zufeng Ge, Hailong Zhou, Yu Feng, Lili Xu, Guoqing Xiao, Yifeng Zheng, Kai Li, Hao Sun, Dong Liu, Hongxia Ni, Jianfeng Yang, Yitao Liu
article en

Abstract

OBJECTIVE: To evaluate the impact of a prostate imaging quality (PI-QUAL) v2 lecture on the accuracy and inter-reader agreement of prostate MRI image-quality assessment among radiologists and technologists from diverse professional backgrounds and institutions, and to evaluate its role in institutional-level quality improvement through a quality control (QC) process. MATERIALS AND METHODS: Ten participants (five radiologists and five technologists) from five different hospitals independently evaluated 15 prostate MRIs before and after a standardized PI-QUAL v2 lecture. Reference scores were established by two experienced radiologists. Concordance with reference was assessed using accuracy and balanced accuracy. Inter-reader agreement was measured using percent agreement (PA) and Gwet's AC1. Subgroup analyses were conducted based on participant characteristics. For the quality assurance and QC (QA/QC), each center submitted 15 prostate MRIs before and after the lecture. Image quality was evaluated centrally to assess institutional improvement. RESULTS: Overall accuracy increased from 66.7% to 76.7%, and balanced accuracy increased from 62.9% to 84.2%; the mixed-effects model indicated significantly higher post-lecture accuracy (p = 0.038). Accuracy was also higher across all subgroups. Inter-reader agreement improved from PA 57.6% to 72.6% and Gwet's AC1 from 0.214 to 0.466. Through the QA/QC process, three centers initially failed to meet PI-QUAL v2 technical criteria. After feedback, all post-intervention scans achieved PI-QUAL v2 scores > 1. CONCLUSION: A structured PI-QUAL v2 lecture improved both the accuracy and inter-reader agreement of prostate MRI image-quality assessments among diverse evaluators. Incorporating QA/QC further enhanced institutional image quality. PI-QUAL v2 training is a feasible strategy for standardizing prostate MRI quality. KEY POINTS: Question Does a structured PI-QUAL v2 lecture for radiologists and technologists improve prostate MRI quality assessment performance and institutional imaging practice across institutions? Findings PI-QUAL v2 training improved accuracy (66.7% to 76.7%) and inter-reader agreement in prostate MRI quality assessment, while QA/QC feedback enhanced institutional imaging quality. Clinical relevance statement Structured PI-QUAL v2 education combined with quality assurance and quality control feedback improves evaluator consistency and institutional prostate MRI quality, facilitating standardized image-quality assessment and broader implementation of high-quality prostate MRI in clinical radiology.

Insights into ImagingVol. 17(1)
University College Hospital (GB), University College London Hospitals NHS Foundation Trust (GB), Chinese Academy of Sciences (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Zhejiang Cancer Hospital (CN), Huzhou Central Hospital (CN), Shaoxing People's Hospital (CN), Hangzhou Institute of Medicine, Chinese Academy of Sciences (CN), University College London (GB)
Peking Union Medical College Hospital, Natural Science Foundation of Zhejiang Province, Science and Technology Program of Zhejiang Province
Good health and well-being
Openalex Percentile: Top 13%
Radiology practices and education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon