AI-Enhanced finite element analysis for optimal material selection in total knee replacement

The increasing prevalence of total knee replacement (TKR) surgery and its association with aseptic loosening present a significant research challenge. This issue can be mitigated by selecting optimal materials for TKR components. This paper presents a hybrid approach combining Finite Element Method (FEM) with Artificial Intelligence (AI) techniques for optimal material selection in TKR. Simulations of four normal movements—compression, distraction, medial bending, and lateral bending—were performed on a 3D model of the artificial knee. Four materials were evaluated: Cobalt-Chromium (Co-Cr), Zirconium (Zr), Stainless Steel, and Titanium (Ti). To simulate ligamentous constraints during distraction loading, a model of a nonlinear spring element was included, furnishing more physiologically realistic boundary conditions. An Artificial Neural Network (ANN) was trained on FEM simulation data to predict material performance with 98.7% accuracy for stress prediction (R 2 = 0.987), while displacement prediction achieved R 2 = 0.985. Multi-criteria decision-making using TOPSIS ranked Co-Cr as the optimal material under stress-prioritized weighting (0.6/0.4); though, sensitivity analysis revealed that Stainless Steel converts optimal when displacement/compliance is prioritized (0.4/0.6). Under axial compression of 1300 N, maximum stress for Co-Cr and Zr was 4.207 × 10 8 N/m 2 and 3.921 × 10 8 N/m 2 , respectively. Under distraction: 4.321 × 10 8 N/m 2 and 4.142 × 10 8 N/m 2 . Under medial bending: 1.101 × 10 8 N/m 2 and 1.088 × 10 8 N/m 2 . Under lateral bending: 1.119 × 10 8 N/m 2 and 1.102 × 10 8 N/m 2 . The AI-based approach reduced computational time by 73% compared to full FEM simulations while maintaining high prediction accuracy. This time-saving shows the promise of the surrogate model for large scale materials screening and patient specific implant optimization, but further biocompatibility and tribological validation will be required for clinical translation of these findings.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-10-29
DOI
https://doi.org/10.3389/fbioe.2026.1959564
Primary Topic
Material Selection and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-Enhanced finite element analysis for optimal material selection in total knee replacement

Iman Shakir Tawfeeq, Taha A Elwi
Frontiers in Bioengineering and Biotechnology
Material Selection and Properties
article

AI-Enhanced finite element analysis for optimal material selection in total knee replacement

Iman Shakir Tawfeeq, Taha A Elwi
article en

Abstract

The increasing prevalence of total knee replacement (TKR) surgery and its association with aseptic loosening present a significant research challenge. This issue can be mitigated by selecting optimal materials for TKR components. This paper presents a hybrid approach combining Finite Element Method (FEM) with Artificial Intelligence (AI) techniques for optimal material selection in TKR. Simulations of four normal movements—compression, distraction, medial bending, and lateral bending—were performed on a 3D model of the artificial knee. Four materials were evaluated: Cobalt-Chromium (Co-Cr), Zirconium (Zr), Stainless Steel, and Titanium (Ti). To simulate ligamentous constraints during distraction loading, a model of a nonlinear spring element was included, furnishing more physiologically realistic boundary conditions. An Artificial Neural Network (ANN) was trained on FEM simulation data to predict material performance with 98.7% accuracy for stress prediction (R 2 = 0.987), while displacement prediction achieved R 2 = 0.985. Multi-criteria decision-making using TOPSIS ranked Co-Cr as the optimal material under stress-prioritized weighting (0.6/0.4); though, sensitivity analysis revealed that Stainless Steel converts optimal when displacement/compliance is prioritized (0.4/0.6). Under axial compression of 1300 N, maximum stress for Co-Cr and Zr was 4.207 × 10 8 N/m 2 and 3.921 × 10 8 N/m 2 , respectively. Under distraction: 4.321 × 10 8 N/m 2 and 4.142 × 10 8 N/m 2 . Under medial bending: 1.101 × 10 8 N/m 2 and 1.088 × 10 8 N/m 2 . Under lateral bending: 1.119 × 10 8 N/m 2 and 1.102 × 10 8 N/m 2 . The AI-based approach reduced computational time by 73% compared to full FEM simulations while maintaining high prediction accuracy. This time-saving shows the promise of the surrogate model for large scale materials screening and patient specific implant optimization, but further biocompatibility and tribological validation will be required for clinical translation of these findings.

Frontiers in Bioengineering and BiotechnologyVol. 14
Nahrain University (IQ)
Good health and well-being
Openalex Percentile: Top 29%
Material Selection and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
AI-Enhanced finite element analysis for optimal material selection in total knee replacement — Iman Shakir Tawfeeq, Taha A Elwi · Frontiers in Bioengineering and Biotechnology (2026) | TGRS Research Map | TGRS