Simple, Fast and Cheap Pb2+ and Hg2+ Detection in Liquid Media Using EGOFET-Based Aptasensors

Lead and mercury are among the most dangerous environmental pollutants due to their high toxicity to humans and other living organisms. They are also ubiquitous in our ecosystems as a result of industrial waste. Therefore, it is essential to develop a simple and inexpensive method to rapidly detect low concentrations of these metals in various liquids, including wastewater. Aptamer-based electrolyte-gated organic field-effect transistors (EGOFETs), which are traditionally used to detect large biomolecules such as viruses and proteins, are a promising concept for heavy-metal detection. To achieve this, we chose several aptamers with high affinity for and specificity to Pb2+ and Hg2+ ions, determined the dissociation constants and stoichiometry of the complexes, investigated the kinetics of complex formation and cross-specificity and proposed structures for the aptamer–cation complexes. Based on these aptamers, we developed EGOFET-based aptasensors for Pb2+ and Hg2+. The fabricated EGOFET devices have been shown to be sensitive to low concentrations of lead (from 30 nM to 2.5 μM) and mercury (from 250 nM to 2.5 μM) cations. These ranges correspond to the maximum permissible concentrations in drinking and wastewater for lead, which are 144 nM and 1.2 μM, respectively, and exceed the range of maximum permissible concentration in drinking and wastewater for mercury, which is 5 nM. Despite this, it was possible to detect mercury cations at a concentration of 5 nM within five minutes in a model system that simulates liquid flow using the EGOFET device. This demonstrates the potential for fast and selective detection of Pb2+ and Hg2+ ions at maximum permissible concentrations in drinking water using EGOFET-based aptasensors. This is a significant step forward in the development of flow sensors for detecting heavy metals in liquid media.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2026-10-29
DOI
https://doi.org/10.3390/ijms27219711
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simple, Fast and Cheap Pb2+ and Hg2+ Detection in Liquid Media Using EGOFET-Based Aptasensors

Elena V. Agina, Dmitry Aleksandrovich Skvortsov, Elena G. Zavyalova, Askar D. Turashev et al.
International Journal of Molecular Sciences
Advanced biosensing and bioanalysis techniques
article

Simple, Fast and Cheap Pb2+ and Hg2+ Detection in Liquid Media Using EGOFET-Based Aptasensors

Elena V. Agina, Dmitry Aleksandrovich Skvortsov, Elena G. Zavyalova, Askar D. Turashev, Olena Yu. Poimanova, Ilya P. Oleynikov, Anna K. Keshek, Margarita S. Stiazhkina, Victor N. Orlov
article en

Abstract

Lead and mercury are among the most dangerous environmental pollutants due to their high toxicity to humans and other living organisms. They are also ubiquitous in our ecosystems as a result of industrial waste. Therefore, it is essential to develop a simple and inexpensive method to rapidly detect low concentrations of these metals in various liquids, including wastewater. Aptamer-based electrolyte-gated organic field-effect transistors (EGOFETs), which are traditionally used to detect large biomolecules such as viruses and proteins, are a promising concept for heavy-metal detection. To achieve this, we chose several aptamers with high affinity for and specificity to Pb2+ and Hg2+ ions, determined the dissociation constants and stoichiometry of the complexes, investigated the kinetics of complex formation and cross-specificity and proposed structures for the aptamer–cation complexes. Based on these aptamers, we developed EGOFET-based aptasensors for Pb2+ and Hg2+. The fabricated EGOFET devices have been shown to be sensitive to low concentrations of lead (from 30 nM to 2.5 μM) and mercury (from 250 nM to 2.5 μM) cations. These ranges correspond to the maximum permissible concentrations in drinking and wastewater for lead, which are 144 nM and 1.2 μM, respectively, and exceed the range of maximum permissible concentration in drinking and wastewater for mercury, which is 5 nM. Despite this, it was possible to detect mercury cations at a concentration of 5 nM within five minutes in a model system that simulates liquid flow using the EGOFET device. This demonstrates the potential for fast and selective detection of Pb2+ and Hg2+ ions at maximum permissible concentrations in drinking water using EGOFET-based aptasensors. This is a significant step forward in the development of flow sensors for detecting heavy metals in liquid media.

International Journal of Molecular SciencesVol. 27(21)
Russian Academy of Sciences (RU), Lomonosov Moscow State University (RU), Central Research Institute of Epidemiology (RU), Institute of Synthetic Polymeric Materials (RU), Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing (RU)
Russian Science Foundation
Clean water and sanitation
Openalex Percentile: Top 23%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.