Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method

This study evaluated the effects of fire class and discharge method on the fire-extinguishing characteristics of HFC-125a gas hydrate fire-extinguishing projectiles. Direct and indirect discharge tests were conducted for Class A and Class B liquid fires using a Grade 4 fire test model based on the “Technical Standards for Type Approval and Product Inspection of Automatic Gas and Powder Fire-Extinguishing Systems.” Fire temperature, oxygen concentration, extinguishing time, and reignition were analyzed. In the Class A Grade 4 direct-discharge test, visible flame was extinguished within approximately 1 s after discharge, and the temperature directly above the fire source decreased from approximately 780 ℃ to 105 ℃ without reignition. In the Class A indirect-discharge test, visible flame was extinguished at 482 s. In the Class B Grade 4 direct-discharge test, fuel scattering and rapid flame spread occurred. Additionally, sustained flaming was observed in the Supplementary Grade 3 test, thus indicating the limited extinguishing applicability of direct discharge. By contrast, indirect discharge extinguished Class B fire at 430 s, thereby reducing the extinguishing time by 153 s—or approximately 26.2%—compared with that (583 s) under natural burning conditions. Therefore, direct discharge is considered suitable for Class A wood fires, whereas indirect discharge is more appropriate for Class B liquid fires.

Authors

Institutions

Publication Details

Journal
Fire science and engineering
Published
2026-10-29
DOI
https://doi.org/10.7731/kifse.ce804e5f
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method

Dong-Gun Nam, Sugil Choi, Seunggeun Park, Sinwoo Kim
4 links
Fire science and engineering
Fire dynamics and safety research
article

Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method

Dong-Gun Nam, Sugil Choi, Seunggeun Park, Sinwoo Kim
article en

Abstract

This study evaluated the effects of fire class and discharge method on the fire-extinguishing characteristics of HFC-125a gas hydrate fire-extinguishing projectiles. Direct and indirect discharge tests were conducted for Class A and Class B liquid fires using a Grade 4 fire test model based on the “Technical Standards for Type Approval and Product Inspection of Automatic Gas and Powder Fire-Extinguishing Systems.” Fire temperature, oxygen concentration, extinguishing time, and reignition were analyzed. In the Class A Grade 4 direct-discharge test, visible flame was extinguished within approximately 1 s after discharge, and the temperature directly above the fire source decreased from approximately 780 ℃ to 105 ℃ without reignition. In the Class A indirect-discharge test, visible flame was extinguished at 482 s. In the Class B Grade 4 direct-discharge test, fuel scattering and rapid flame spread occurred. Additionally, sustained flaming was observed in the Supplementary Grade 3 test, thus indicating the limited extinguishing applicability of direct discharge. By contrast, indirect discharge extinguished Class B fire at 430 s, thereby reducing the extinguishing time by 153 s—or approximately 26.2%—compared with that (583 s) under natural burning conditions. Therefore, direct discharge is considered suitable for Class A wood fires, whereas indirect discharge is more appropriate for Class B liquid fires.

Fire science and engineeringVol. 40(5)
Korea Fire Institute (KR)
Openalex Percentile: Top 13%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Evaluation of Fire-Extinguishing Performance of HFC-125a Gas Hydrate Fire-Extinguishing Projectiles Based on Discharge Method — Dong-Gun Nam, Sugil Choi, et al. · Fire science and engineering (2026) | TGRS Research Map | TGRS