Assessment of Carotid Siphon Pulsatility Index via Transorbital Window, an Alternative for Intracranial Measurements

Objective: To analyze the correlation between the hemodynamic indices of the carotid siphon (CS), the middle cerebral artery (MCA) and the optic nerve sheath diameter (ONSD) among patients with acute brain injuries. Materials and methods: An observational, analytical, and cross-sectional study was conducted. Pulsatility indices (PI) of the CS and MCA were recorded using transcranial Doppler, and ONSD was measured using ocular ultrasound. Pearson’s and Spearman’s correlation coefficients were applied, considering statistical significance at p < 0.005. Results: A total of 75 neurocritical patients were enrolled during 2024. A strong positive correlation was observed between the CS PI and the MCA PI, in both the right (r = 0.643; p < 0.001) and left (r = 0.702; p < 0.001) hemispheres. A weak but significant positive correlation was found between the left CS PI and left ONSD (r = 0.242; p = 0.039). Patients with a PI greater than 1.2 had a larger ONSD than those with a PI of 1.2 or lower (t = −2.29; p = 0.025). The mean difference was approximately 0.44 mm, based on the 95% confidence interval from −0.830 to −0.057. This association was observed only in the left hemisphere and showed a moderate effect size (Cohen’s d = −0.61). Conclusions: In this cohort of neurocritical patients, the carotid siphon pulsatility index showed a strong correlation with the middle cerebral artery pulsatility index, suggesting concordant hemodynamic behavior between both sites of insonation and supporting the potential of the carotid siphon as an alternative for Doppler evaluation when the acoustic window is limited. An optic nerve sheath enlargement may be associated with higher pulsatility index; however, invasive ICP monitoring is needed to evaluate the reliability of this association.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2026-10-29
DOI
https://doi.org/10.3390/brainsci16111177
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Carotid Siphon Pulsatility Index via Transorbital Window, an Alternative for Intracranial Measurements

Sérgio Brasil, Geovanny Gabriel García Cox, María Gabriela De La Cruz Novoa, Oswaldo Andrés Bolaños Ladinez et al.
Brain Sciences
Traumatic Brain Injury and Neurovascular Disturbances
article

Assessment of Carotid Siphon Pulsatility Index via Transorbital Window, an Alternative for Intracranial Measurements

Sérgio Brasil, Geovanny Gabriel García Cox, María Gabriela De La Cruz Novoa, Oswaldo Andrés Bolaños Ladinez, Fernando Roosemberg, Paula Olivos Massa
article en

Abstract

Objective: To analyze the correlation between the hemodynamic indices of the carotid siphon (CS), the middle cerebral artery (MCA) and the optic nerve sheath diameter (ONSD) among patients with acute brain injuries. Materials and methods: An observational, analytical, and cross-sectional study was conducted. Pulsatility indices (PI) of the CS and MCA were recorded using transcranial Doppler, and ONSD was measured using ocular ultrasound. Pearson’s and Spearman’s correlation coefficients were applied, considering statistical significance at p < 0.005. Results: A total of 75 neurocritical patients were enrolled during 2024. A strong positive correlation was observed between the CS PI and the MCA PI, in both the right (r = 0.643; p < 0.001) and left (r = 0.702; p < 0.001) hemispheres. A weak but significant positive correlation was found between the left CS PI and left ONSD (r = 0.242; p = 0.039). Patients with a PI greater than 1.2 had a larger ONSD than those with a PI of 1.2 or lower (t = −2.29; p = 0.025). The mean difference was approximately 0.44 mm, based on the 95% confidence interval from −0.830 to −0.057. This association was observed only in the left hemisphere and showed a moderate effect size (Cohen’s d = −0.61). Conclusions: In this cohort of neurocritical patients, the carotid siphon pulsatility index showed a strong correlation with the middle cerebral artery pulsatility index, suggesting concordant hemodynamic behavior between both sites of insonation and supporting the potential of the carotid siphon as an alternative for Doppler evaluation when the acoustic window is limited. An optic nerve sheath enlargement may be associated with higher pulsatility index; however, invasive ICP monitoring is needed to evaluate the reliability of this association.

Brain SciencesVol. 16(11)
Universidade de São Paulo (BR), Universidad Espíritu Santo (EC)
Good health and well-being
Openalex Percentile: Top 14%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon