The Correction Factor for Monitoring Efanesoctocog Alfa Is Not Always 2.5

INTRODUCTION: Efanesoctocog alfa (Altuvoct) is a recombinant super-extended half-life factor (F)VIII concentrate licensed in the United Kingdom for patients with severe and moderate haemophilia A. Concentrate potency is assigned by one-stage assays (OSA) using Actin FSL. Chromogenic FVIII:C assays (CA) and some OSA are inaccurate for Altuvoct; the product information sheet suggests results of these be divided by 2.5 to approximate FVIII:C. UK experts recommend against using correction factors (CF), with guidance that only validated OSA should be used for Altuvoct, or, in the presence of FVIII-mimetics, that CA results are reported with a caveat about assay inaccuracy. METHODS: Over four months, we assessed the impact of a fixed CF on FVIII:C, testing 70 samples collected during pharmacokinetic assessment when patients switched to Altuvoct. All were tested using OSA (Actin FSL and Actin FS) and CA (BIOPHEN and Siemens FVIII:C) on a Sysmex CN-6500 analyser, calibrated against a plasma standard. RESULTS: For samples with Altuvoct between 10 and 269 IU/dL, CF increased as FVIII:C increased when using CA and decreased when using OSA (Actin FS), suggesting that a single CF across that range is inappropriate. CONCLUSIONS: A universal CF for Altuvoct assays may lead to clinically significant FVIII:C underestimation across the measurement range, and is inappropriate in most cases. Should product-specific calibrators (and controls) become available, laboratories should verify their assays for Altuvoct using them so that CF are not required.

Authors

Institutions

Publication Details

Journal
Haemophilia
Published
2026-10-29
DOI
https://doi.org/10.1111/hae.70443
Primary Topic
Hemophilia Treatment and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Correction Factor for Monitoring Efanesoctocog Alfa Is Not Always 2.5

Suthesh Sivapalaratnam, Sean Platton, Priyanka Raheja, Janine Collins et al.
4 links
Haemophilia
Hemophilia Treatment and Research
article

The Correction Factor for Monitoring Efanesoctocog Alfa Is Not Always 2.5

Suthesh Sivapalaratnam, Sean Platton, Priyanka Raheja, Janine Collins, Laurie Aiken, Jude Platton, Katarzyna Kniola
article en

Abstract

INTRODUCTION: Efanesoctocog alfa (Altuvoct) is a recombinant super-extended half-life factor (F)VIII concentrate licensed in the United Kingdom for patients with severe and moderate haemophilia A. Concentrate potency is assigned by one-stage assays (OSA) using Actin FSL. Chromogenic FVIII:C assays (CA) and some OSA are inaccurate for Altuvoct; the product information sheet suggests results of these be divided by 2.5 to approximate FVIII:C. UK experts recommend against using correction factors (CF), with guidance that only validated OSA should be used for Altuvoct, or, in the presence of FVIII-mimetics, that CA results are reported with a caveat about assay inaccuracy. METHODS: Over four months, we assessed the impact of a fixed CF on FVIII:C, testing 70 samples collected during pharmacokinetic assessment when patients switched to Altuvoct. All were tested using OSA (Actin FSL and Actin FS) and CA (BIOPHEN and Siemens FVIII:C) on a Sysmex CN-6500 analyser, calibrated against a plasma standard. RESULTS: For samples with Altuvoct between 10 and 269 IU/dL, CF increased as FVIII:C increased when using CA and decreased when using OSA (Actin FS), suggesting that a single CF across that range is inappropriate. CONCLUSIONS: A universal CF for Altuvoct assays may lead to clinically significant FVIII:C underestimation across the measurement range, and is inappropriate in most cases. Should product-specific calibrators (and controls) become available, laboratories should verify their assays for Altuvoct using them so that CF are not required.

Haemophilia
Queen Mary University of London (GB), Barts Health NHS Trust (GB), Royal London Hospital (GB), Blizard Institute (GB)
Good health and well-being
Openalex Percentile: Top 12%
Hemophilia Treatment and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
The Correction Factor for Monitoring Efanesoctocog Alfa Is Not Always 2.5 — Suthesh Sivapalaratnam, Sean Platton, et al. · Haemophilia (2026) | TGRS Research Map | TGRS