Device-Derived Digital Biomarkers During SGLT2 Inhibitor Therapy: A Secondary Analysis of the ERASe Trial

Aims: Implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy defibrillators (CRT-D) provide continuous physiological data reflecting heart failure (HF) status and autonomic tone. Sodium–glucose cotransporter-2 inhibitors (SGLT2i) are core HF therapy, but it remains unclear whether their physiological effects are detectable using device-based remote monitoring. Following the ERASe trial, which showed reduced ventricular arrhythmias with ertugliflozin, this post-hoc analysis evaluated its impact on ICD/CRT-D-derived parameters. Methods: In this prospective, randomized ERASe post-hoc analysis, ertugliflozin was compared with placebo over 12 months in patients with ICD or CRT-D devices. Device-derived parameters including 24 h heart rate, night heart rate, heart rate variability, physical activity, and thoracic impedance were assessed at baseline and follow-up. Analyses were predefined as exploratory. Results: Forty-six patients (22 ertugliflozin, 24 placebo) had ≥1 analysable parameter. Paired longitudinal data were available for 29 patients for 24 h heart rate (HR), 19 for night HR, 17 for HR variability, and 9 for thoracic impedance. No significant between-group differences were observed in 24 h HR, physical activity or thoracic impedance. No significant differential longitudinal treatment effects were observed for the evaluated device-derived parameters, although estimates were imprecise because of limited parameter-specific data availability. Assessment of associations with arrhythmic and heart-failure outcomes was precluded by small event numbers and incomplete parameter-specific data. Conclusions: Ertugliflozin did not significantly alter individual device-derived parameters. Larger studies are needed to determine whether device-based physiological signals can identify treatment-related changes.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-10-29
DOI
https://doi.org/10.3390/jcm15218441
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Device-Derived Digital Biomarkers During SGLT2 Inhibitor Therapy: A Secondary Analysis of the ERASe Trial

Martin Manninger, Katharina Ingrid Gölly, Dirk von Lewinski, Martin Benedikt et al.
7 links
Journal of Clinical Medicine
Cardiac pacing and defibrillation studies
article

Device-Derived Digital Biomarkers During SGLT2 Inhibitor Therapy: A Secondary Analysis of the ERASe Trial

Martin Manninger, Katharina Ingrid Gölly, Dirk von Lewinski, Martin Benedikt, Andreas Zirlik, Douglas S. Scherr, M Stuehlinger, Harald Sourij, Lukas Herold, Ursula Rohrer, Viktoria Santner, Johannes Widkal, Simon Leiter
article en

Abstract

Aims: Implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy defibrillators (CRT-D) provide continuous physiological data reflecting heart failure (HF) status and autonomic tone. Sodium–glucose cotransporter-2 inhibitors (SGLT2i) are core HF therapy, but it remains unclear whether their physiological effects are detectable using device-based remote monitoring. Following the ERASe trial, which showed reduced ventricular arrhythmias with ertugliflozin, this post-hoc analysis evaluated its impact on ICD/CRT-D-derived parameters. Methods: In this prospective, randomized ERASe post-hoc analysis, ertugliflozin was compared with placebo over 12 months in patients with ICD or CRT-D devices. Device-derived parameters including 24 h heart rate, night heart rate, heart rate variability, physical activity, and thoracic impedance were assessed at baseline and follow-up. Analyses were predefined as exploratory. Results: Forty-six patients (22 ertugliflozin, 24 placebo) had ≥1 analysable parameter. Paired longitudinal data were available for 29 patients for 24 h heart rate (HR), 19 for night HR, 17 for HR variability, and 9 for thoracic impedance. No significant between-group differences were observed in 24 h HR, physical activity or thoracic impedance. No significant differential longitudinal treatment effects were observed for the evaluated device-derived parameters, although estimates were imprecise because of limited parameter-specific data availability. Assessment of associations with arrhythmic and heart-failure outcomes was precluded by small event numbers and incomplete parameter-specific data. Conclusions: Ertugliflozin did not significantly alter individual device-derived parameters. Larger studies are needed to determine whether device-based physiological signals can identify treatment-related changes.

Journal of Clinical MedicineVol. 15(21)
Innsbruck Medical University (AT), Universität Innsbruck (AT), Medical University of Graz (AT)
Good health and well-being
Openalex Percentile: Top 11%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon