Alarm Fatigue and Clinical Alarm Management in the Neonatal Intensive Care Unit: A Scoping Review of Quality Improvement Interventions, Outcome Metrics, and Implementation Lessons

Background Alarm fatigue in neonatal intensive care units (NICUs) may affect patient safety, staff well-being, and the developmental care environment. NICU alarm-management interventions have been reported across quality improvement (QI), before-after, randomized crossover, implementation, and observational designs, but outcome definitions, denominators, and safety measures remain heterogeneous. Objective To map NICU alarm-management interventions and related implementation studies, emphasizing intervention components, outcome metrics, alarm-burden outcomes, clinical safety measures, and implementation lessons. Methods This scoping review followed PRISMA-ScR guidance. PubMed/MEDLINE, Embase, CINAHL, and Cochrane Library were searched, with an updated search through June 2026. Eligible reports involved neonatal or newborn intensive care settings and addressed alarm fatigue, clinical alarm management, alarm burden, alarm thresholds, alarm delays, alarm routing, or related QI or implementation approaches. Two reviewers screened records and charted data. A protocol was predefined before screening but was not prospectively registered. Full database-specific search strategies are provided in Supplementary Appendix A. Owing to heterogeneity in designs, denominators, and outcome definitions, findings were synthesized descriptively and were not pooled. Results Sixteen studies/reports met inclusion criteria. The PRISMA-ScR flow diagram shows 20 records identified, 0 duplicates removed, 20 records screened, 3 excluded at title/abstract screening, 17 full texts assessed, 1 full text excluded, and 16 studies included. Included studies addressed alarm-threshold or parameter optimization, oxygen-saturation alarm strategies, staff education, protocol standardization, PDSA-based QI, alarm delay/filtering, handheld-device routing, and single-room NICU alarm workflows. Reported alarm reductions were directionally favorable in many studies, but denominators differed substantially, including total alarms, SpO 2 alarms, false alarms, non-actionable alarms, and alarms transmitted to handheld devices. Conclusions The NICU alarm-management literature describes cautiously favorable alarm-burden trends after carefully implemented, patient-tailored, multidisciplinary approaches, while reported monitored safety outcomes were generally maintained in published studies. However, most evidence is observational, before-after, or QI in design; therefore, conclusions should remain descriptive and cautious. Limitations include heterogeneous outcome definitions, English-language full-text restriction, and limited long-term and economic data. The evidence does not support ranking intervention combinations or making causal comparative-effectiveness claims. Future work should use standardized NICU-specific alarm outcomes, predefined balancing safety measures, long-term sustainability assessment, and economic evaluation.

Authors

Institutions

Publication Details

Journal
Journal of Neonatology
Published
2026-10-29
DOI
https://doi.org/10.1177/09732179261495641
Primary Topic
Healthcare Technology and Patient Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Alarm Fatigue and Clinical Alarm Management in the Neonatal Intensive Care Unit: A Scoping Review of Quality Improvement Interventions, Outcome Metrics, and Implementation Lessons

Somashekhar Marutirao Nimbalkar, Lalan Kumar Bharti, Aditya Hemendra Bhatt
4 links
Journal of Neonatology
Healthcare Technology and Patient Monitoring
article

Alarm Fatigue and Clinical Alarm Management in the Neonatal Intensive Care Unit: A Scoping Review of Quality Improvement Interventions, Outcome Metrics, and Implementation Lessons

Somashekhar Marutirao Nimbalkar, Lalan Kumar Bharti, Aditya Hemendra Bhatt
article en

Abstract

Background Alarm fatigue in neonatal intensive care units (NICUs) may affect patient safety, staff well-being, and the developmental care environment. NICU alarm-management interventions have been reported across quality improvement (QI), before-after, randomized crossover, implementation, and observational designs, but outcome definitions, denominators, and safety measures remain heterogeneous. Objective To map NICU alarm-management interventions and related implementation studies, emphasizing intervention components, outcome metrics, alarm-burden outcomes, clinical safety measures, and implementation lessons. Methods This scoping review followed PRISMA-ScR guidance. PubMed/MEDLINE, Embase, CINAHL, and Cochrane Library were searched, with an updated search through June 2026. Eligible reports involved neonatal or newborn intensive care settings and addressed alarm fatigue, clinical alarm management, alarm burden, alarm thresholds, alarm delays, alarm routing, or related QI or implementation approaches. Two reviewers screened records and charted data. A protocol was predefined before screening but was not prospectively registered. Full database-specific search strategies are provided in Supplementary Appendix A. Owing to heterogeneity in designs, denominators, and outcome definitions, findings were synthesized descriptively and were not pooled. Results Sixteen studies/reports met inclusion criteria. The PRISMA-ScR flow diagram shows 20 records identified, 0 duplicates removed, 20 records screened, 3 excluded at title/abstract screening, 17 full texts assessed, 1 full text excluded, and 16 studies included. Included studies addressed alarm-threshold or parameter optimization, oxygen-saturation alarm strategies, staff education, protocol standardization, PDSA-based QI, alarm delay/filtering, handheld-device routing, and single-room NICU alarm workflows. Reported alarm reductions were directionally favorable in many studies, but denominators differed substantially, including total alarms, SpO 2 alarms, false alarms, non-actionable alarms, and alarms transmitted to handheld devices. Conclusions The NICU alarm-management literature describes cautiously favorable alarm-burden trends after carefully implemented, patient-tailored, multidisciplinary approaches, while reported monitored safety outcomes were generally maintained in published studies. However, most evidence is observational, before-after, or QI in design; therefore, conclusions should remain descriptive and cautious. Limitations include heterogeneous outcome definitions, English-language full-text restriction, and limited long-term and economic data. The evidence does not support ranking intervention combinations or making causal comparative-effectiveness claims. Future work should use standardized NICU-specific alarm outcomes, predefined balancing safety measures, long-term sustainability assessment, and economic evaluation.

Journal of Neonatology
All India Institute of Medical Sciences Raipur (IN), Government of India (IN), Pramukhswami Medical College (IN), Bhaikaka University (IN)
Good health and well-being
Openalex Percentile: Top 10%
Healthcare Technology and Patient Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon