Recovering rooftop photovoltaic array tilt and azimuth from operational power data

Performance benchmarking and fault detection in distributed photovoltaic systems depend on a theoretical generation reference that requires accurate panel tilt and azimuth as inputs to the irradiance transposition model. In practice, orientation metadata is often missing or derived from design documentation without verification against the physical installation. Data-driven methods that recover orientation from operational power data have been proposed, but no systematic evaluation has examined how irradiance source quality and partial shading affect recovery accuracy. This study evaluated four method combinations on 17 commercially operated Australian rooftop systems with independently verified orientations and documented shading status. For these systems, clear-sky methods gave smaller orientation errors than ERA5 reanalysis methods with both objective functions. On unshaded systems, clear-sky methods achieved median tilt and azimuth errors of 2 ° and 4 ° , while ERA5 methods produced tilt errors of 10 ° to 12 ° and azimuth errors of 48 ° to 62 ° . The clear-sky median azimuth error increased from 4 ° on unshaded systems to 35 ° on shaded systems due to partial shading. A geometric limit on azimuth recovery was identified for systems with panel tilt below 5 ° , where annual plane-of-array irradiance is nearly insensitive to azimuth orientation. For low-tilt rooftop systems in Australia, panel orientation can therefore be recovered from operational DC data without physical inspection. The recovered orientation can improve the reliability of performance benchmarks and fault detection where orientation records are unverified or missing. The approach could support large-scale PV monitoring, where site inspection is impractical.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2026-10-29
DOI
https://doi.org/10.1016/j.solener.2026.115313
Primary Topic
Solar Radiation and Photovoltaics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recovering rooftop photovoltaic array tilt and azimuth from operational power data

Fiacre Emile Rougieux, Chris Martell, Earl R. Duran, Hanrong Huang et al.
2 links
Solar Energy
Solar Radiation and Photovoltaics
article

Recovering rooftop photovoltaic array tilt and azimuth from operational power data

Fiacre Emile Rougieux, Chris Martell, Earl R. Duran, Hanrong Huang, Bernardo Mendonca Severiano, Yang Tang
article en

Abstract

Performance benchmarking and fault detection in distributed photovoltaic systems depend on a theoretical generation reference that requires accurate panel tilt and azimuth as inputs to the irradiance transposition model. In practice, orientation metadata is often missing or derived from design documentation without verification against the physical installation. Data-driven methods that recover orientation from operational power data have been proposed, but no systematic evaluation has examined how irradiance source quality and partial shading affect recovery accuracy. This study evaluated four method combinations on 17 commercially operated Australian rooftop systems with independently verified orientations and documented shading status. For these systems, clear-sky methods gave smaller orientation errors than ERA5 reanalysis methods with both objective functions. On unshaded systems, clear-sky methods achieved median tilt and azimuth errors of 2 ° and 4 ° , while ERA5 methods produced tilt errors of 10 ° to 12 ° and azimuth errors of 48 ° to 62 ° . The clear-sky median azimuth error increased from 4 ° on unshaded systems to 35 ° on shaded systems due to partial shading. A geometric limit on azimuth recovery was identified for systems with panel tilt below 5 ° , where annual plane-of-array irradiance is nearly insensitive to azimuth orientation. For low-tilt rooftop systems in Australia, panel orientation can therefore be recovered from operational DC data without physical inspection. The recovered orientation can improve the reliability of performance benchmarks and fault detection where orientation records are unverified or missing. The approach could support large-scale PV monitoring, where site inspection is impractical.

Solar EnergyVol. 321
Chinese Academy of Sciences (CN), UNSW Sydney (AU), Shanghai Institute of Applied Physics (CN), Sustainable Energy Systems (United Kingdom) (GB)
Affordable and clean energy, Climate action
Openalex Percentile: Top 14%
Solar Radiation and Photovoltaics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon