Comparative evaluation of carotid artery stent designs through a strict randomized evidence synthesis and assessment of local vascular responses

Carotid artery stenting is an established endovascular option for carotid stenosis, but comparative clinical evidence for individual stent designs remains limited. Full-text reassessment confirmed five independent trials that randomized patients specifically to a stent device or stent-design strategy. Only two trials (204 patients; four standardized events) provided fully verified arm-level data for stroke, transient ischemic attack, or all-cause death within 30 days. The device evidence formed a sparse chain without a closed loop, and each direct comparison was informed by one trial. Bayesian network meta-analysis, treatment ranking, and node-splitting were therefore not performed. Direct estimates were imprecise and did not establish superiority of any stent or structural class. The animal findings describe exploratory local vascular responses to geometry-matched miniature nitinol stents under controlled experimental conditions and do not validate a clinical device hierarchy. The chronological relationship between the clinical evidence review and animal study design is acknowledged as a limitation.

Authors

Institutions

Publication Details

Journal
Journal of Biomaterials Applications
Published
2026-10-29
DOI
https://doi.org/10.1177/08853282261501990
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of carotid artery stent designs through a strict randomized evidence synthesis and assessment of local vascular responses

Kuo Li, Chunyan Zhang, L. Wang, Xiaoxuan Wang et al.
1 links
Journal of Biomaterials Applications
Cerebrovascular and Carotid Artery Diseases
article

Comparative evaluation of carotid artery stent designs through a strict randomized evidence synthesis and assessment of local vascular responses

Kuo Li, Chunyan Zhang, L. Wang, Xiaoxuan Wang, Ruyue Wang
article en

Abstract

Carotid artery stenting is an established endovascular option for carotid stenosis, but comparative clinical evidence for individual stent designs remains limited. Full-text reassessment confirmed five independent trials that randomized patients specifically to a stent device or stent-design strategy. Only two trials (204 patients; four standardized events) provided fully verified arm-level data for stroke, transient ischemic attack, or all-cause death within 30 days. The device evidence formed a sparse chain without a closed loop, and each direct comparison was informed by one trial. Bayesian network meta-analysis, treatment ranking, and node-splitting were therefore not performed. Direct estimates were imprecise and did not establish superiority of any stent or structural class. The animal findings describe exploratory local vascular responses to geometry-matched miniature nitinol stents under controlled experimental conditions and do not validate a clinical device hierarchy. The chronological relationship between the clinical evidence review and animal study design is acknowledged as a limitation.

Journal of Biomaterials Applications
Cangzhou Central Hospital (CN)
Good health and well-being
Openalex Percentile: Top 12%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon