Feasibility of Accelerometer-Based Arterial Pulse Measurement: Part I—Theoretical Analysis

Despite their commercial availability and portability, accelerometers (ACCs) are much less frequently used for arterial pulse waveform (APW) measurement, and the resulting acceleration pulse waveform (APWa) has been much less studied than the APW measured by a tactile sensor. This paper, the first of two parts, presents a theoretical analysis of the feasibility of ACC-based arterial pulse measurement at rest, focusing on the measurement-related technical issues underlying the differences from tactile-based measurement. The tissue–contact–sensor (TCS) stack between the artery and ACC is modeled as a single-degree-of-freedom (SDOF) system to collectively capture the dynamic behavior of all the factors involved during pulse measurement, where motion artifact (MA) is quantified as low-frequency (<0.7 Hz) mechanical motion of the ACC and alters tissue prestress, resulting in time-varying system parameters (TVSPs) in the SDOF system. Theoretical relations are established among the arterial pulse signal, MA, TCS system parameters, and measured acceleration. The analysis reveals that, even in the absence of MA, the measured acceleration differs fundamentally from the displacement-domain APW because of the dynamic response of the TCS stack and the nonstationary nature of the arterial pulse signal. In the presence of MA, the measured acceleration is affected through two mechanisms: MA itself, represented as baseline drift (BD), and TVSP-induced distortion. While MA itself can be removed using conventional filtering, TVSP-induced distortion is embedded within individual arterial pulse harmonics. Numerical simulations illustrate these effects by comparing displacement- and acceleration-domain signals with and without MA and further demonstrate the distinct effects of TVSP-induced distortion on the instantaneous parameters of a harmonic. These findings provide a theoretical basis for the experimental investigation and evaluation in Part II and a mechanistic basis for MA and sensor-noise removal in ACC-measured pulse signals.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-10-29
DOI
https://doi.org/10.3390/s26216832
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of Accelerometer-Based Arterial Pulse Measurement: Part I—Theoretical Analysis

Mamun Hasan, Zhili Hao
3 links
Sensors
Non-Invasive Vital Sign Monitoring
article

Feasibility of Accelerometer-Based Arterial Pulse Measurement: Part I—Theoretical Analysis

Mamun Hasan, Zhili Hao
article en

Abstract

Despite their commercial availability and portability, accelerometers (ACCs) are much less frequently used for arterial pulse waveform (APW) measurement, and the resulting acceleration pulse waveform (APWa) has been much less studied than the APW measured by a tactile sensor. This paper, the first of two parts, presents a theoretical analysis of the feasibility of ACC-based arterial pulse measurement at rest, focusing on the measurement-related technical issues underlying the differences from tactile-based measurement. The tissue–contact–sensor (TCS) stack between the artery and ACC is modeled as a single-degree-of-freedom (SDOF) system to collectively capture the dynamic behavior of all the factors involved during pulse measurement, where motion artifact (MA) is quantified as low-frequency (<0.7 Hz) mechanical motion of the ACC and alters tissue prestress, resulting in time-varying system parameters (TVSPs) in the SDOF system. Theoretical relations are established among the arterial pulse signal, MA, TCS system parameters, and measured acceleration. The analysis reveals that, even in the absence of MA, the measured acceleration differs fundamentally from the displacement-domain APW because of the dynamic response of the TCS stack and the nonstationary nature of the arterial pulse signal. In the presence of MA, the measured acceleration is affected through two mechanisms: MA itself, represented as baseline drift (BD), and TVSP-induced distortion. While MA itself can be removed using conventional filtering, TVSP-induced distortion is embedded within individual arterial pulse harmonics. Numerical simulations illustrate these effects by comparing displacement- and acceleration-domain signals with and without MA and further demonstrate the distinct effects of TVSP-induced distortion on the instantaneous parameters of a harmonic. These findings provide a theoretical basis for the experimental investigation and evaluation in Part II and a mechanistic basis for MA and sensor-noise removal in ACC-measured pulse signals.

SensorsVol. 26(21)
Old Dominion University (US)
Good health and well-being
Openalex Percentile: Top 25%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Feasibility of Accelerometer-Based Arterial Pulse Measurement: Part I—Theoretical Analysis — Mamun Hasan, Zhili Hao · Sensors (2026) | TGRS Research Map | TGRS