Can we assess brain perfusion on a regional basis from digital subtraction angiography images with motion artifacts?

BACKGROUND: A method called IPEN (for Intra-operative PErfusion assessment with No gantry rotation) has been developed that uses x-ray angiography images and assesses volumetric soft tissue perfusion on a regional basis. It has the potential to enable quantitative cross-sectional perfusion assessment before, during, and after interventional procedures, such that physicians can assess the risk and outcome of the procedure. However, the current IPEN will not function if there is no native (non-subtracted) x-ray angiography images available and digital subtraction angiography (DSA) images are corrupted by motion artifacts. PURPOSE: To demonstrate that region-based tissue enhancement can be extracted from DSA images even if they are contaminated by motion artifacts. METHODS: We developed a motion-compensating IPEN framework using DSA images (called MCI-D) and validated its core formulation. A key breakthrough enabling MCI-D was the finding that, even when DSA images contain motion artifacts, subtracting two DSA images can isolate the change in tissue enhancement between the images if motion is absent between the two times. RESULTS: A qualitative assessment using computer simulated XCAT perfusion phantom data validated the finding, and clinical data supported the feasibility. An extensive, systematic, and quantitative assessment showed that MCI-D was highly correlated to the ground truth (e.g., the correlation coefficients > 0.99 for both the time-enhancement curve and the blood flow perfusion index, maximum slope of the rising part of the time-enhancement curve). CONCLUSIONS: MCI-D enables accurate motion-compensated perfusion assessment from DSA images, even in the presence of severe motion artifacts, provided that the motion is not continuous and occurs within a short period of time.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-10-28
DOI
https://doi.org/10.1002/mp.70728
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can we assess brain perfusion on a regional basis from digital subtraction angiography images with motion artifacts?

Katsuyuki Taguchi, W. Paul Segars, Andreia Vasconcellos Faria, Shalini Subramanian
4 links
Medical Physics
Medical Imaging Techniques and Applications
article

Can we assess brain perfusion on a regional basis from digital subtraction angiography images with motion artifacts?

Katsuyuki Taguchi, W. Paul Segars, Andreia Vasconcellos Faria, Shalini Subramanian
article en

Abstract

BACKGROUND: A method called IPEN (for Intra-operative PErfusion assessment with No gantry rotation) has been developed that uses x-ray angiography images and assesses volumetric soft tissue perfusion on a regional basis. It has the potential to enable quantitative cross-sectional perfusion assessment before, during, and after interventional procedures, such that physicians can assess the risk and outcome of the procedure. However, the current IPEN will not function if there is no native (non-subtracted) x-ray angiography images available and digital subtraction angiography (DSA) images are corrupted by motion artifacts. PURPOSE: To demonstrate that region-based tissue enhancement can be extracted from DSA images even if they are contaminated by motion artifacts. METHODS: We developed a motion-compensating IPEN framework using DSA images (called MCI-D) and validated its core formulation. A key breakthrough enabling MCI-D was the finding that, even when DSA images contain motion artifacts, subtracting two DSA images can isolate the change in tissue enhancement between the images if motion is absent between the two times. RESULTS: A qualitative assessment using computer simulated XCAT perfusion phantom data validated the finding, and clinical data supported the feasibility. An extensive, systematic, and quantitative assessment showed that MCI-D was highly correlated to the ground truth (e.g., the correlation coefficients > 0.99 for both the time-enhancement curve and the blood flow perfusion index, maximum slope of the rising part of the time-enhancement curve). CONCLUSIONS: MCI-D enables accurate motion-compensated perfusion assessment from DSA images, even in the presence of severe motion artifacts, provided that the motion is not continuous and occurs within a short period of time.

Medical PhysicsVol. 53(11)
Johns Hopkins University (US), Duke University (US), Johns Hopkins Medicine (US)
National Institutes of Health
Good health and well-being
Openalex Percentile: Top 13%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon