Dynamic modelling of a high-temperature latent heat store for stable compressor operation in a solar-assisted thermo-mechanical vapour compression cooling system

Solar-assisted thermo-mechanical vapour compression cooling delivers part of the compression work by heating the refrigerant at constant volume using solar-heated water at 98–120 °C. However, operation beyond sunset relies on sensible hot-water storage, whose declining temperature causes the thermal compressor to switch repeatedly in and out of the circuit, imposing step load changes on the mechanical compressor. The integration of a high-temperature latent heat store with such a cycle has not previously been reported. This study presents such a system, using erythritol (melting point 117 °C) in a shell-and-tube configuration. A transient two-dimensional model of the store, validated against experimental and numerical benchmarks to within 6%, is dynamically coupled with a stratified sensible store, a solar collector field, and the cooling cycle serving a residential building in Baghdad, Iraq, with a peak cooling load of 521 kW. Without latent storage, the mechanical compressor undergoes 45 load swings per night with step changes of up to 30 kW; a 20 mm PCM layer eliminates these fluctuations by holding the supply temperature above the thermal compressor threshold throughout the 5.7-h night-time discharge, extending solar-driven operation at a system COP of 3.83. Heat penetration saturates at approximately 17.5 mm, identifying 20 mm as the design thickness. Seasonally, the integrated system reduces compressor electricity consumption by 20.5% relative to a conventional vapour compression baseline, up to 24% on the July design day. The results establish operational stability, rather than energy savings alone, as the principal value of high-temperature latent storage in solar-driven cooling.

Authors

Institutions

Publication Details

Journal
International Journal of Refrigeration
Published
2026-10-28
DOI
https://doi.org/10.1016/j.ijrefrig.2026.107194
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic modelling of a high-temperature latent heat store for stable compressor operation in a solar-assisted thermo-mechanical vapour compression cooling system

Rabah Boukhanouf, Hussein A. Al Khiro
International Journal of Refrigeration
Phase Change Materials Research
article

Dynamic modelling of a high-temperature latent heat store for stable compressor operation in a solar-assisted thermo-mechanical vapour compression cooling system

Rabah Boukhanouf, Hussein A. Al Khiro
article en

Abstract

Solar-assisted thermo-mechanical vapour compression cooling delivers part of the compression work by heating the refrigerant at constant volume using solar-heated water at 98–120 °C. However, operation beyond sunset relies on sensible hot-water storage, whose declining temperature causes the thermal compressor to switch repeatedly in and out of the circuit, imposing step load changes on the mechanical compressor. The integration of a high-temperature latent heat store with such a cycle has not previously been reported. This study presents such a system, using erythritol (melting point 117 °C) in a shell-and-tube configuration. A transient two-dimensional model of the store, validated against experimental and numerical benchmarks to within 6%, is dynamically coupled with a stratified sensible store, a solar collector field, and the cooling cycle serving a residential building in Baghdad, Iraq, with a peak cooling load of 521 kW. Without latent storage, the mechanical compressor undergoes 45 load swings per night with step changes of up to 30 kW; a 20 mm PCM layer eliminates these fluctuations by holding the supply temperature above the thermal compressor threshold throughout the 5.7-h night-time discharge, extending solar-driven operation at a system COP of 3.83. Heat penetration saturates at approximately 17.5 mm, identifying 20 mm as the design thickness. Seasonally, the integrated system reduces compressor electricity consumption by 20.5% relative to a conventional vapour compression baseline, up to 24% on the July design day. The results establish operational stability, rather than energy savings alone, as the principal value of high-temperature latent storage in solar-driven cooling.

International Journal of RefrigerationVol. 193
University of Nottingham (GB)
Higher Committee for Education Development in Iraq
Affordable and clean energy, Climate action
Openalex Percentile: Top 23%
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon