Conditional Root-Stress Exceedance of a 220 kV Disconnect Switch Under Dynamic Slurry–Boulder Debris-Flow Loading

Distributed slurry pressure and local boulder pulses can induce transient stresses in outdoor disconnect switches. This study evaluates conditional root-stress exceedance in an idealized 220 kV disconnect-switch model with prescribed geometry, tied connections, fixed bases, equivalent linear-elastic materials, and separately imposed load histories. Four fixed screening levels of 165, 235, 282, and 375 MPa were considered. The original coarse-mesh (N1) archive contains 213 distinct loading cases, including 100 combined-load cases at four prescribed heights and matched component, height, and load-model checks. The primary demand is the maximum von Mises invariant of the tensor averaged at the original monitored root point. The same 100 combined-load cases were evaluated on the G3H3 and G4H4 meshes in a paired comparison. From G3H3 to G4H4, the median absolute point-demand change was 4.87%, the maximum relative change in the fitted median exceedance velocity was 2.45%, and the largest same-velocity exceedance-probability difference was 21.85 percentage points. The primary curves exceeded the proposed numerical sensitivity targets. The point demands increased by 23.43–27.72% from N1 to G4H4, demonstrating the mesh dependence of the original results. A fixed-volume tensor response was more stable, but remains supplementary and does not validate the point metric. The pressure-redistribution checks used two selected scenarios, and the component comparisons at the two greater heights used eight matched cases per height. These checks illustrate numerical sensitivity and case-specific differences within the N1 reference model; they do not constitute a comprehensive uncertainty analysis or establish physical failure probabilities. This exploratory numerical case study quantifies stress-screening sensitivity within the adopted idealization rather than reconstructing a specific installed unit. No mesh-independent local peak, calibrated physical damage state, or site-specific failure probability is established.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-10-28
DOI
https://doi.org/10.3390/app162110662
Primary Topic
Landslides and related hazards
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conditional Root-Stress Exceedance of a 220 kV Disconnect Switch Under Dynamic Slurry–Boulder Debris-Flow Loading

Yindong Gong, Yanhui Liu, Jinqiang Peng, Liang Cheng et al.
Applied Sciences
Landslides and related hazards
article

Conditional Root-Stress Exceedance of a 220 kV Disconnect Switch Under Dynamic Slurry–Boulder Debris-Flow Loading

Yindong Gong, Yanhui Liu, Jinqiang Peng, Liang Cheng, Tianlang Li
article en

Abstract

Distributed slurry pressure and local boulder pulses can induce transient stresses in outdoor disconnect switches. This study evaluates conditional root-stress exceedance in an idealized 220 kV disconnect-switch model with prescribed geometry, tied connections, fixed bases, equivalent linear-elastic materials, and separately imposed load histories. Four fixed screening levels of 165, 235, 282, and 375 MPa were considered. The original coarse-mesh (N1) archive contains 213 distinct loading cases, including 100 combined-load cases at four prescribed heights and matched component, height, and load-model checks. The primary demand is the maximum von Mises invariant of the tensor averaged at the original monitored root point. The same 100 combined-load cases were evaluated on the G3H3 and G4H4 meshes in a paired comparison. From G3H3 to G4H4, the median absolute point-demand change was 4.87%, the maximum relative change in the fitted median exceedance velocity was 2.45%, and the largest same-velocity exceedance-probability difference was 21.85 percentage points. The primary curves exceeded the proposed numerical sensitivity targets. The point demands increased by 23.43–27.72% from N1 to G4H4, demonstrating the mesh dependence of the original results. A fixed-volume tensor response was more stable, but remains supplementary and does not validate the point metric. The pressure-redistribution checks used two selected scenarios, and the component comparisons at the two greater heights used eight matched cases per height. These checks illustrate numerical sensitivity and case-specific differences within the N1 reference model; they do not constitute a comprehensive uncertainty analysis or establish physical failure probabilities. This exploratory numerical case study quantifies stress-screening sensitivity within the adopted idealization rather than reconstructing a specific installed unit. No mesh-independent local peak, calibrated physical damage state, or site-specific failure probability is established.

Applied SciencesVol. 16(21)
Guangzhou University (CN), China Southern Power Grid (China) (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 9%
Landslides and related hazards
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon